The gain of silicon photomultipliers (SiPMs) increases with bias voltage and decreases with temperature. To operate SiPMs at stable gain, the bias voltage can be readjusted to compensate for temperature changes. We have tested this concept…

Instrumentation and Detectors · Physics 2019-05-22 G. Eigen , J. Cvach , J. Kvasnicka , I. Polak , A. Træet , J. Zalieckas

The gain of SiPMs depends both on bias voltage and on temperature. For stable operations, both need to be kept constant. In an ILC calorimeter with millions of channels, this is a challenging task. It is, therefore, desirable to compensate…

Instrumentation and Detectors · Physics 2014-04-01 Jaroslav Cvach , Gerald Eigen , Jiri Kvasnicka , Ivo Polak , Erik van der Kraiij , Justas Zalieckas

We present herein gain stabilization studies of SiPMs using a climate chamber at CERN. We present results for four detectors not tested before, three from Hamamatsu and one from KETEK. Two of the Hamamatsu SiPMs are novel sensors with…

Instrumentation and Detectors · Physics 2016-03-02 Gerald Eigen , Are Træet , Justas Zalieckas , Jaroslav Cvach , Jiri Kvasnicka , Ivo Polak

Silicon Photomultipliers (SiPM) represent a promising alternative to classical photomultipliers, for instance, for the detection of photons in high energy physics and medical physics. In the present work, electrical characterizations of…

Instrumentation and Detectors · Physics 2017-08-23 M. J. Boschini , C. Consolandi , P. G. Fallica , M. Gervasi , D. Grandi , M. Mazzillo , S. Pensotti , P. G. Rancoita , D. Sanfilippo , M. Tacconi , G. Valvo

This paper reports on the behaviour of Silicon Photomultiplier (SiPM) detectors under continuous light. Usually, the bias circuit of a SiPM has a resistor connected in series to it, which protects the sensor from drawing too high current.…

Instrumentation and Detectors · Physics 2020-01-29 A. Nagai , C. Alispach , D. della Volpe , M. Heller , T. Montaruli , S. Njoh , Y. Reniera , I. Troyano-Pujadas

We present experimental results of characterization of Silicon photomultipliers (SiPM) in a temperature range from 90~mK to 40~K. Two SiPMs, one from ONSEMI and one from Hamamatsu Photonics were tested. Operating voltage ranges, dark count…

Instrumentation and Detectors · Physics 2025-01-13 Otto Hanski , Tom Kiilerich , Sampsa Ahopelto , Aleksei Semakin , Janne Ahokas , Viacheslav Dvornichenko , Sergey Vasiliev

Silicon Photo-Multipliers (SiPM) are regarded as novel photo-detectors to replace conventional Photo-Multiplier Tubes (PMTs). However, the breakdown voltage dependence on the ambient temperature results in a gain variation of $\sim$3$\%…

Instrumentation and Methods for Astrophysics · Physics 2017-01-18 Zhengwei Li , Congzhan Liu , Yupeng Xu , Bo Yan , Yanguo Li , Xuefeng Lu , Xufang Li , Shuo Zhang , Zhi Chang , Jicheng Li , Yifei Zhang , Jianling Zhao

Each satellite of the Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM, mission) consists of 25 SiPM based gamma-ray detectors (GRDs). Although SiPM based GRD has merits of compact size and low bias-voltage,…

The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating…

Instrumentation and Detectors · Physics 2022-07-20 E. Garutti , R. Klanner , E. Popova , S. Martens , J. Schwandt , C. Villalba

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their performance in the absence of an external electric field. The…

Instrumentation and Detectors · Physics 2018-10-17 X. L. Sun , T. Tolba , G. F. Cao , P. Lv , L. J. Wen , A. Odian , F. Vachon , A. Alamre , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. S. Barbeau , D. Beck , V. Belov , T. Bhatta , F. Bourque , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , L. Cao , W. R. Cen , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , M. Côté , A. Craycraft , W. Cree , J. Dalmasson , T. Daniels , L. Darroch , S. J. Daugherty , J. Daughhetee , S. Delaquis , A. Der Mesrobian-Kabakian , R. DeVoe , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , J. Echevers , L. Fabris , D. Fairbank , W. Fairbank , J. Farine , S. Feyzbakhsh , P. Fierlinger , R. Fontaine , D. Fudenberg , G. Gallina , G. Giacomini , R. Gornea , G. Gratta , E. V. Hansen , D. Harris , M. Heffner , E. W. Hoppe , J. Hößl , A. House , P. Hufschmidt , M. Hughes , Y. Ito , A. Iverson , A. Jamil , C. Jessiman , M. J. Jewell , X. S. Jiang , A. Karelin , L. J. Kaufman , D. Kodroff , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , A. Larson , D. S. Leonard , G. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , T. Michel , M. Moe , B. Mong , D. C. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , O. Nusair , K. Odgers , M. Oriunno , J. L. Orrell , G. S. Ortega , I. Ostrovskiy , C. T. Overman , S. Parent , A. Piepke , A. Pocar , J. -F. Pratte , D. Qiu , V. Radeka , E. Raguzin , T. Rao , S. Rescia , F. Retière , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , J. Schneider , D. Sinclair , K. Skarpaas VIII , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , M. Tarka , J. Todd , T. I. Totev , R. Tsang , T. Tsang , B. Veenstra , V. Veeraraghavan , G. Visser , J. -L. Vuilleumier , M. Wagenpfeil , Q. Wang , J. Watkins , M. Weber , W. Wei , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , Q. Xia , L. Yang , Y. -R. Yen , O. Zeldovich , J. Zhao , Y. Zhou , T. Ziegler

The use of silicon photomultipliers (SiPMs) in imaging atmospheric Cherenkov telescopes is expected to extend the observation times of very-high-energy gamma-ray sources, particularly within the highest energy domain of 50-300 TeV, where…

Instrumentation and Methods for Astrophysics · Physics 2023-09-19 Akira Okumura , Kawori Wakazono , Kazuhiro Furuta , Hiroyasu Tajima

Decreasing the operation temperature of a Silicon Photo-Multiplier (SiPM) leads to a drop in its dark noise. Some experiments consider cold temperatures as an option for low noise applications of SiPM. One of those is the TAO detector,…

Instrumentation and Detectors · Physics 2021-03-17 N. Anfimov , D. Fedoseev , A. Rybnikov , A. Selyunin , S. Sokolov , A. Sotnikov

This article presents the development of a cost-effective and efficient electronic module for silicon photomultipliers (SiPM). The electronic module combines essential functionalities, such as a high voltage power supply, a preamplifier,…

Instrumentation and Detectors · Physics 2023-09-07 A. Sadigov , S. Nuruyev , R. Akbarov , D. B. Berikov , A. Madadzada , A. Mammadli

Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area…

Instrumentation and Detectors · Physics 2011-09-23 Gama Ahmed , Paul Bühler , Johann Marton , Ken Suzuki

ASTRI SST-2M is one of the prototypes of the small size class of telescopes proposed for the Cherenkov Telescope Array. Its optical design is based on a dual-mirror Schwarzschild-Couder configuration, and the camera is composed by a matrix…

Instrumentation and Methods for Astrophysics · Physics 2016-12-08 D. Impiombato , O. Catalano , S. Giarrusso , T. Mineo , G. La Rosa , C. Gargano , P. Sangiorgi , A. Segreto , G. Sottile , G. Bonanno , S. Garozzo , A. Grillo , D. Marano , G. Romeo , R. Gimenes

We have designed a system to stabilize the gain of a submillimeter heterodyne receiver against thermal fluctuations of the mixing element. In the most sensitive heterodyne receivers, the mixer is usually cooled to 4 K using a closed-cycle…

The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher…

Future high-energy physics experiments using SiPMs as photosensitive elements may require operation at low temperatures (down to 80 K) to measure single photons with high time resolution in a highly radioactive environment. This calls for a…

Instrumentation and Detectors · Physics 2026-02-02 P. Carniti , C. Gotti , G. Pessina , D. Trotta

We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor…

Instrumentation and Detectors · Physics 2020-01-23 Tyana Stiegler , Kareem Kazkaz , Erik Swanberg , Vladimir Mozin

Silicon photomultiplier (SiPM), as the core photoelectric sensor for coherent neutrino detection in low-temperature pure CsI, its working performance directly determines the measurement accuracy of the scintillator light yield. Our previous…

Instrumentation and Detectors · Physics 2025-10-29 Tao Liu , Xilei Sun , Fengjiao Luo , Jingbo Ye , Bo Zheng , Cong Guo , Zhilong Hou , Rongbin Zhou , Aiqin Gao , Lei Cao , Bo Zhang , Sijia Han