Related papers: High Precision Measurement of the $^{19}$Ne Half-l…
Neutrinoless double-beta ($0\nu\beta\beta$) decay and the standard two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{98}$Mo have been studied. The double-beta decay $Q$-value has been determined as $Q_{\beta\beta}=113.668(68)$ keV…
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of $\tau_n = (886.3 \pm 1.2 [\textrm{stat}] \pm 3.2 [\textrm{syst}])$ s. The dominant uncertainties were attributed to…
The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve…
Lifetimes in the yrast bands of the nuclei $^{182,186}$Pt have been measured using the Doppler-shift Recoil Distance technique. The results in both cases {\em viz.} a sharp increase in B(E2) values at very low spins, may be interpreted as…
The beta-decay half-life of 62Ga has been studied with high precision using on-line mass separated samples. The decay of 62Ga which is dominated by a 0+ to 0+ transition to the ground state of 62Zn yields a half-life of T_{1/2} = 116.19(4)…
This paper proposes a high-precision time measurement method based on digital frequency-domain phase-fitting (DFPF) by using the digitized nuclear pulses. The averaging effect inherent in the frequency-domain cross-correlation and…
A neutron decays into a proton, an electron, and an anti-neutrino through the beta-decay process. The decay lifetime ($\sim$880 s) is an important parameter in the weak interaction. For example, the neutron lifetime is a parameter used to…
The half-life of 66Ga, an isotope very important for high-energy efficiency calibration of gamma-detectors, has been measured using gamma-spectroscopy. In order to reduce systematic uncertainties, different source production methods and…
This paper reports the first application of a new technique to measure the beta-decay half -lives of exotic nuclei in complex background conditions. Since standard tools were not adapted to extract the relevant information, a new analysis…
We used the 8$\pi$ $\gamma$-ray spectrometer at the TRIUMF-ISAC radiocative ion beam facility to obtain high-precision branching ratios for $^{19}$Ne $\beta^+$ decay to excited states in $^{19}$F. Together with other previous work, our…
$Background:$ Previous measurements of $\beta$-delayed neutron emitters comprise around 230 nuclei, spanning from the $^{8}$He up to $^{150}$La. Apart from $^{210}$Tl, with a minuscule branching ratio of 0.007\%, no other neutron emitter is…
A search for the radiative neutrinoless double electron capture with single \gray\ emission has been performed in $^{58}$Ni. Gamma radiation from a 7286 g nickel sample in natural isotope composition was measured for 58.3 d with an ultra…
This document presents the measurement of $B^0$ meson lifetimes using the 2019 Belle II dataset that corresponds to an integrated luminosity of $8.7 \pm 0.2$ fb$^{-1}$. Each candidate is fully reconstructed with hadronic decay final states…
Investigation of the $^{50}$V electron-capture to the $2^+$ 1553.8 keV level of $^{50}$Ti and search for $\beta^-$ decay of $^{50}$V to the $2^+$ 783.3 keV level of $^{50}$Cr (both those decays are fourfold forbidden with $\Delta J^{\Delta…
The Xi^+_c lifetime is measured using 9.0 fb^-1 of e+e- annihilation data collected on and just below the Upsilon(4S) resonance with the CLEO II.V detector at CESR. This is the first measurement of the Xi^+_c lifetime from a collider…
A search for the electron capture of Te-123 has been performed using CdZnTe detectors. After a measuring time of 195 h no signal could be found resulting in a lower half-life limt of $T_{1/2} > 3.2 \cdot 10^{16}$ yrs (95 % CL) for this…
The results by A.S. Barabash [Phys. Rev. {\bf C 81}, 035501 (2010)] are shown to be incomplete. Tellurium data sets were reanalyzed using the best practices of ENSDF evaluations. Present analysis indicates much higher value for the…
Starting from June 2011, the activity of a 137Cs source has been measured by means of a HPGe detector installed deep underground in the Gran Sasso Laboratory. In total about 5100 energy spectra, one hour measuring time each, have been…
A direct measurement of the ground-state-to-ground-state electron-capture decay $Q$ ($Q_{\rm EC}$) value of $^{97}$Tc has been conducted employing the high resolving power phase-imaging ion-cyclotron-resonance technique with the double…
We report a precise measurement of $^{216}\rm Po$ half-life using the PandaX-4T liquid xenon time projection chamber (TPC). $^{220}\rm Rn $, emanating from a $^{228}\rm Th $ calibration source, is injected to the detector and undergoes…