English
Related papers

Related papers: Development of a compact ExB microchannel plate de…

200 papers

Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel…

Instrumentation and Detectors · Physics 2014-11-18 T. Lari

We propose a novel x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), with which a very high angular resolution can be achieved even with a small system size. MIXIM is composed of equally-spaced multiple slits and an…

The Multi-Chip-Module-Deposited (MCM-D) technique has been used to build hybrid pixel detector assemblies. This paper summarises the results of an analysis of data obtained in a test beam campaign at CERN. Here, single chip hybrids made of…

Instrumentation and Detectors · Physics 2008-11-26 K. -H. Becks , P. Gerlach , C. Grah , P. Maettig , T. Rohe

The TORCH time-of-flight detector is designed to provide particle identification in the momentum range 2-10 GeV/c over large areas. The detector exploits prompt Cherenkov light produced by charged particles traversing a 10 mm thick quartz…

The Argonne micro-channel plate photomultiplier tube (MCP-PMT) is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein \mbox{6 $\times$ 6 cm$^2$} sized detectors are made at Argonne National Laboratory.…

Instrumentation and Detectors · Physics 2018-03-14 Greig A. Cowan , Franz Muheim , Matthew Needham , Silvia Gambetta , Stephan Eisenhardt , Neil McBlane , Matthew Malek

A current-biased kinetic inductance detector (CB-KID) is a novel superconducting detector to construct a neutron transmission imaging system. The characteristics of a superconducting neutron detector have been systematically studied to…

The PAMELA apparatus has been assembled and it is ready to be launched in a satellite mission to study mainly the antiparticle component of cosmic rays. In this paper the performances obtained for the silicon microstrip detectors used in…

Microchannel plates (MCPs) were the driving detector technology for ultraviolet (UV) astronomy over many years, and still today MCP-based detectors are the baseline for several planned UV instruments. The development of advanced MCP…

Instrumentation and Methods for Astrophysics · Physics 2025-12-11 S. Diebold , J. Barnstedt , L. Conti , H. R. Elsener , L. Hanke , M. Höltzli , C. Kalkuhl , D. Rau , D. Schaadt , T. Schanz , B. Stelzer , K. Werner

The current CMS silicon pixel detector as the innermost component of the CMS experiment is performing well at LHC design luminosity, but would be subject to severe inefficiencies at LHC peak luminosities of 2x10e34 cm^-2 s^-1. Therefore, an…

Instrumentation and Detectors · Physics 2015-05-15 Simon Spannagel

We present a detailed study of an 8-channel $1\times1$ mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline.…

We have developed and successfully tested a prototype of a new type of high position resolution hybrid X-ray detector. It contains a thin wall lead glass capillary plate converter of X-rays combined with a microgap parallel-plate avalanche…

Instrumentation and Detectors · Physics 2015-06-26 C. Iacobaeus , T. Francke , B. Lund-Jensen , J. Ostling , P. Pavlopoulos , V. Peskov , F. Tokanai

A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and…

A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$\mu$m. To solidify this concept, the…

Instrumentation and Detectors · Physics 2021-08-18 ALICE ITS project , : , G. Aglieri Rinella , M. Agnello , B. Alessandro , F. Agnese , R. S. Akram , J. Alme , E. Anderssen , D. Andreou , F. Antinori , N. Apadula , P. Atkinson , R. Baccomi , A. Badalà , A. Balbino , C. Bartels , R. Barthel , F. Baruffaldi , I. Belikov , S. Beole , P. Becht , A. Bhatti , M. Bhopal , N. Bianchi , M. B. Blidaru , G. Boca , J. Bok , G. Bonomi , M. Bonora , M. Borri , V. Borshchov , E. Botta , G. E. Bruno , M. Buckland , S. Bufalino , M. Cai , P. Camerini , P. Cariola , F. Catalano , C. Ceballos Sanchez , I. Chakaberia , M. Chartier , F. Colamaria , D. Colella , A. Collu , M. Concas , G. Contin , S. Costanza , P. Cui , A. Dainese , J. B. Dainton , L. De Cilladi , C. De Martin , G. De Robertis , W. Deng , A. Di Mauro , Y. Ding , M. Durkac , D. Elia , M. R. Ersdal , M. Faggin , F. Fan , A. Fantoni , P. Fecchio , A. Feliciello , G. Feofilov , A. Ferk , J. Ferencei , G. Fiorenza , A. N. Flores , E. Fragiacomo , D. Gajanana , A. Gal , C. Gao , C. Gargiulo , P. Gianotti , P. Giubilato , A. Grant , L. Greiner , A. Grelli , O. S. Groettvik , F. Grosa , C. Guo Hu , R. Hannigan , J. A. Hasenbichler , H. Helstrup , H. Hillemanns , C. Hills , P. Hindley , B. Hippolyte , B. Hofman , G. H. Hong , G. Huang , J. P. Iddon , H. Ilyas , M. A. Imhoff , A. Isakov , A. Jadlovska , S. Jadlovska , J. Jadlovsky , S. Jaelani , T. Johnson , A. Junique , P. Kalinak , A. Kalweit , M. Keil , Z. Khabanova , H. Khan , B. Kim , C. Kim , J. Kim , J. Kim , T. Kim , J. Klein , A. Kluge , C. Kobdaj , A. Kotliarov , I. Králik , F. Krizek , T. Kugathasan , C. Kuhn , P. G. Kuijer , S. Kushpil , M. J. Kweon , J. Y. Kwon , Y. Kwon , P. La Rocca , A. Lakrathok , R. Langoy , P. Larionov , E. Laudi , T. Lazareva , R. Lea , R. C. Lemmon , X. L. Li , J. Lien , B. Lim , S. H. Lim , S. Lindsay , A. Liu , J. Liu , J. Liu , M. Lunardon , G. Luparello , M. Lupi , M. Mager , A. Maire , Q. W. Malik , G. Mandaglio , V. Manzari , Y. Mao , G. V. Margagliotti , C. Markert , D. Marras , P. Martinengo , S. Masciocchi , M. Masera , A. Masoni , A. Mastroserio , P. F. T. Matuoka , G. Mazza , F. Mazzaschi , M. A. Mazzoni , F Morel , V. Muccifora , A. Mulliri , L. Musa , S. V. Nesbo , D. Nesterov , J. Norman , J. Park , R. N Patra , C. Pastore , H. Pei , X. Peng , S. Piano , C. Pinto , S. Pisano , S. Politano , E. Prakasa , F. Prino , M. Protsenko , M. Puccio , A. Rachevski , L. Ramello , F. Rami , I. Ravasenga , A. Rehman , F. Reidt , F. Riggi , K. Røed , D. Röhrich , F. Ronchetti , A. Rosano , M. J. Rossewij , A. Rossi , R. Rui , R. Russo , R. Sadikin , V. Sarritzu , J. Schambach , S. Senyukov , J. J. Seo , R. Shahoyan , S. Shaukat , S. Siddhanta , M. Sitta , R. J. M. Snellings , W. Snoeys , A. Songmoolnak , J. Sonneveld , F. Soramel , M. Suljic , S. Sumowidagdo , D. Sun , X. Sun , G. J. Tambave , G. Tersimonov , M. Tkacik , M. Toppi , A. Trifiró , S. Trogolo , V. Trubnikov , R. Turrisi , T. S. Tveter , I. Tymchuck , K. Ullaland , M. Urioni , G. L. Usai , N. Valle , L. V. R. van Doremalen , T. Vanat , J. W. Van Hoorne , M. Varga-Kofarago , A. Velure , D. Wang , Y. Wang , J. Wikne , J. R. Wright , R. Xu , P. Yang , Z. Yin , I. -K. Yoo , J. H. Yoon , S. Yuan , V. Zaccolo , E. Zhang , X. Zhang , V. Zherebchevskii , D. Zhou , J. Zhu , Y. Zhu , G. Zinovjev , N. Zurlo

The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of…

Instrumentation and Detectors · Physics 2014-11-20 A. Bell , E. Castro , R. Hall-Wilton , W. Lange , W. Lohmann , A. Macpherson , M. Ohlerich , N. Rodriguez , V. Ryjov , R. S. Schmidt , R. L. Stone

A novel beam profiler based on microstructured scintillation resin is presented. The detector consists of a bundle of waveguides, with an active area of 30 x 30 mm$^2$ and a pitch of 400 $\mu$m, obtained by molding a scintillating resin…

We present a novel single-photon detector based on a vacuum tube incorporating a photocathode, a microchannel plate (MCP), and a Timepix4 CMOS ASIC functioning as a pixelated anode. Designed to handle photon rates up to 1 billion per second…

Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial…

Instrumentation and Detectors · Physics 2020-08-26 L. M. S. Margato , A. Morozov , A. Blanco , P. Fonte , L. Lopes , K. Zeitelhack , R. Hall-Wilton , C. Höglund , L. Robinson , S. Schmidt , P. Svensson

The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron…

Photographic emulsion is a particle tracking device which features the best spatial resolution among particle detectors. For certain applications, for example muon radiography, large-scale detectors are required. Therefore, a huge surface…

Instrumentation and Detectors · Physics 2016-03-07 T. Ariga , A. Ariga , K. Kuwabara , K. Morishima , M. Moto , A. Nishio , P. Scampoli , M. Vladymyrov

We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used…