English

Measurements of Spatial Resolution of ATLAS Pixel Detectors

Instrumentation and Detectors 2014-11-18 v1

Abstract

Standard as well as irradiated silicon pixel detectors developed for the ATLAS experiment were tested in a beam. Digital and analog resolutions were determined comparing the positions measured by a microstrip telescope and by the pixel detector. Digital resolutions of 10 um and analog resolutions of 6 um (before irradiation) and 10 um (after irradiation) are obtained without subtracting the error on the position determined by the telescope.

Keywords

Cite

@article{arxiv.physics/0012046,
  title  = {Measurements of Spatial Resolution of ATLAS Pixel Detectors},
  author = {T. Lari},
  journal= {arXiv preprint arXiv:physics/0012046},
  year   = {2014}
}

Comments

4 pages, 3 figures. Contribution to Pixel 2000 Conference (Genoa, Italy, June 2000). To be published in the Proceedings of the conference on NIM