English
Related papers

Related papers: High-power closed-cycle $^4$He cryostat with top-l…

200 papers

In-vacuo cryogenic environments are ideal for applications requiring both low temperatures and extremely low particle densities. This enables reaching long storage and coherence times for example in ion traps, essential requirements for…

In this article we summarize experimental work on cryogen-free 3He/4He dilution refrigerators which, in addition to the dilution refrigeration circuit, are equipped with a 4He-1K-stage. This type of DR becomes worth considering when high…

Other Condensed Matter · Physics 2014-12-12 Kurt Uhlig

Here we report the performance of a small scale 4 K pulse tube cryocooler operating with a low input power reaching a minimum temperature of 2.2 K, as well as a cooling capacity of over 240 mW at 4.2 K. The compressor is air cooled and can…

We present a novel cooling method that uses the phase separation and evaporative cooling of 3He to reach and continuously maintain sub-kelvin temperatures. While less complex than a dilution refrigerator, the system performs similarly to a…

Other Condensed Matter · Physics 2025-03-17 P. H. Kim , M. Hirschel , J. Suranyi , J. P. Davis

We demonstrate successful operation of a continuous flow liquid helium magnetic cryostat (Oxford Instruments, Microstat MO) in closed cycle operation using a modular cryocooling system (ColdEdge Technologies, Stinger). For the system…

Instrumentation and Detectors · Physics 2022-01-04 K. Barr , T. Cookson , K. G. Lagoudakis

He-3/He-4 dilution refrigerators (DR) are very common in sub-Kelvin temperature research. We describe a pulse tube precooled DR where a separate He-4 circuit condenses the He-3 of the dilution loop. Whereas in our previous work the dilution…

Instrumentation and Detectors · Physics 2014-12-12 K. Uhlig

A cryogen-free cryostat cooled using a 4 K commercial GM or pulse tube cryocooler (PTC) displays temperature oscillations caused by the intrinsic working principle of the regenerative cryocooler. To dampen such oscillations usually requires…

A cryogen-free cryostat cooled by a closed cycle cryocooler is compact, can provide uninterrupted long-term operation (up to ten thousand hours) and is suited to temperatures from 3 K to 300 K. Its intrinsic temperature oscillation,…

We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and…

Instrumentation and Detectors · Physics 2022-11-10 S. M. Fleischer , M. P. Ross , K. Venkateswara , C. A. Hagedorn , E. A. Shaw , E. Swanson , B. R. Heckel , J. H. Gundlach

At the Walther-Mei{\ss}ner-Institut (WMI), a new cryogen-free 3He/4He dilution refrigerator (DR) has been completed; the cryostat will be employed to cool experiments on superconducting quantum circuits for quantum information technology…

Other Condensed Matter · Physics 2014-12-12 A. Marx , J. Hoess , K. Uhlig

A thermal heat switch has been developed intended for cryogenic space applications operating around 100 K. The switch was designed to separate two pulse tube cold heads that cool a common focal plane array. Two cold heads are used for…

Instrumentation and Detectors · Physics 2013-11-26 Marc Dietrich , Andreas Euler , Günter Thummes

We describe a helium source cell for use in cryogenic experiments that is hermetically sealed $in$ $situ$ on the cold plate of a cryostat. The source cell is filled with helium gas at room temperature and subsequently sealed using a cold…

Instrumentation and Detectors · Physics 2023-11-06 K. E. Castoria , H. Byeon , J. Theis , N. R. Beysengulov , E. O. Glen , G. Koolstra , M. Sammon , S. A. Lyon , J. Pollanen , D. G. Rees

A two-stage Stirling-type U-shape pulse tube cryocooler driven by a 10 kW-class linear compressor was designed, built and tested. A special feature of the cold head is the absence of a heat exchanger at the cold end of the first stage,…

Instrumentation and Detectors · Physics 2014-11-20 M. Dietrich , G. Thummes

We describe the preparation of ultra cold atomic clouds in a dilution refrigerator. The closed cycle 3He/4He cryostat was custom made to provide optical access for laser cooling, optical manipulation and detection of atoms. We show that the…

Liquid Helium is used widely, from hospitals to characterization of materials at low temperatures. Many experiments at low temperatures require liquid Helium, particularly when vibration isolation precludes the use of cryocoolers and when…

We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (> 99.999%) and…

Instrumentation and Methods for Astrophysics · Physics 2014-07-21 Shugo Oguri , Jihoon Choi , Masanori Kawai , Osamu Tajima

Cryogenic environments benefit ion trapping experiments by offering lower motional heating rates, collision energies, and an ultra-high vacuum (UHV) environment for maintaining long ion chains for extended periods of time. Mechanical…

Solid-state thermoelectric cooling is expected to be widely used in various cryogenic applications such as local cooling of superconducting devices. At present, however, thermoelectric cooling using p- and n-type Bi2Te3-based materials has…

Materials Science · Physics 2020-06-12 Yoshihiko Okamoto , Yuma Yoshikawa , Taichi Wada , Koshi Takenaka

Closed cycle $He^{3}-He^{4}$ dilution cryostats became the platform of choice in quantum sciences in the era of helium shortage. However, in many experiments, the mechanical vibrations induced by the pulsed cryocoolers present a significant…

Mesoscale and Nanoscale Physics · Physics 2023-02-28 Jacob Franklin , Joshua Bedard , Ilya Sochnikov

Current vapor-compression technology is based on the gas-liquid transition of hazardous gas. The alternative cooling technology focuses on the solid caloric material. A new liquid barocaloric material, i.e. the liquid crystal, is proved to…

Soft Condensed Matter · Physics 2016-09-27 Zhongjian Xie , Yao Zhu