English
Related papers

Related papers: High-power closed-cycle $^4$He cryostat with top-l…

200 papers

Enabling temperature dependent experiments in Atomic Force Microscopy is of great interest to study materials and surface properties at the nanoscale. By studying Curie temperature of multiferroic materials, temperature based phase…

Instrumentation and Detectors · Physics 2018-07-19 A. del Moral , J. C. González-Rosillo , A. Gómez , T. Puig , X. Obradors

We have investigated the quantum-to-thermal crossover temperature T* for cavitation in liquid helium mixtures up to 0.05 3He concentrations. With respect to the pure 4He case, T* is sizeably reduced, to a value below 50 mK for 3He…

Condensed Matter · Physics 2009-10-28 D. Jezek , M. Guilleumas , M. Pi , M. Barranco

We present the design and calibration measurements of a scanning tunneling microscope setup in a 3He ultrahigh-vacuum cryostat operating at 400 mK with a hold time of 10 days. With 2.70 m in height and 4.70 m free space needed for assembly,…

We present two simple cryogenic RF ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 hours. The ion traps are operated either in a liquid helium bath cryostat or in a low…

Instrumentation and Detectors · Physics 2009-02-10 P. B. Antohi , D. Schuster , G. M. Akselrod , J. Labaziewicz , Y. Ge , Z. Lin , W. S. Bakr , I. L. Chuang

$^4$He confined in nanoporous media is a model Bose system that exhibits quantum phase transition (QPT) by varying pressure. We have precisely determined the critical exponent of the superfluid density of $^4$He in porous Gelsil glasses…

Superconductivity · Physics 2021-04-14 Tomoyuki Tani , Yusuke Nago , Satoshi Murakawa , Keiya Shirahama

This is the report on new development of an automated precision load-based measurement setup for thermoelectric power of different types of samples in the temperature range 5 - 330 K. The problems in the old spring-based setup have been…

Applied Physics · Physics 2019-03-12 Tarachand , Monika Saxena , Bodhoday Mukherjee , Gunadhor S. Okram

Experiments performed at a temperature of a few millikelvin require effective thermalization schemes, low-pass filtering of the measurement lines and low-noise electronics. Here, we report on the modifications to a commercial dilution…

We show that, at high densities, fully variational solutions of solid-like type can be obtained from a density functional formalism originally designed for liquid 4He. Motivated by this finding, we propose an extension of the method that…

Other Condensed Matter · Physics 2009-11-11 F. Ancilotto , M. Barranco , F. Caupin , R. Mayol , M. Pi

We report studies of solid helium contained inside a torsional oscillator, at temperatures between 1.07K and 1.87K. We grew single crystals inside the oscillator using commercially pure $^4$He and $^3$He-$^4$He mixtures containing 100 ppm…

Other Condensed Matter · Physics 2011-03-01 Anna Eyal , Emil Polturak

We experimentally demonstrated a new method for reducing the vibration of the cold stage of a cryocooler. Comparing the RMS amplitude with the case of no phase shift of the driving gas pressure between the two pairs, the longitudinal…

Instrumentation and Detectors · Physics 2007-05-23 T. Suzuki , T. Tomaru , T. Haruyama , N. Sato , A. Yamamoto , T. Shintomi , Y. Ikushima , R. Li

We have examined superfluid properties of $^4$He confined to a nano-porous Gelsil glass that has nanopores 2.5 nm in diameter. The pressure-temperature phase diagram was determined by torsional oscillator, heat capacity and pressure…

Mesoscale and Nanoscale Physics · Physics 2009-11-13 Keiya Shirahama , Keiichi Yamamoto , Yoshiyuki Shibayama

The cryogenic underground observatory for rare events (CUORE) is a 1-ton scale bolometric experiment whose detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. This will be the largest…

We report on our design of a scanning gate microscope housed in a cryogen-free dilution refrigerator with a base temperature of 15 mK. The recent increase in efficiency of pulse tube cryocoolers has made cryogen-free systems popular in…

Instrumentation and Detectors · Physics 2014-09-09 Matthew Pelliccione , Adam Sciambi , John Bartel , Andrew Keller , David Goldhaber-Gordon

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221 Two continuous closed-cycle hydrogen Joule-Thomson (J-T) sorption coolers have been fabricated and assembled…

Instrumentation and Methods for Astrophysics · Physics 2010-01-27 G. Morgante , D. Pearson , F. Melot , P. Stassi , L. Terenzi , P. Wilson , B. Hernandez , L. Wade , A. Gregorio , M. Bersanelli , C. Butler , N. Mandolesi

Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons…

On-chip refrigeration at cryogenic temperatures is becoming an important requirement in the context of quantum technologies and nanoelectronics. Ferroic materials with enhanced electrocaloric effects at phase transitions are good material…

Materials Science · Physics 2024-03-28 Jalaja M A , Shubham Kumar Parate , Binoy Krishna De , Sai Dutt K , Pavan Nukala

This paper presents a physics-based analytical model for the MOS transistor operating continuously from room temperature down to liquid-helium temperature (4.2 K) from depletion to strong inversion and in the linear and saturation regimes.…

Mesoscale and Nanoscale Physics · Physics 2018-08-17 Arnout Beckers , Farzan Jazaeri , Christian Enz

We model the low-temperature specific heat of solid $^4$He in the hexagonal closed packed structure by invoking two-level tunneling states in addition to the usual phonon contribution of a Debye crystal for temperatures far below the Debye…

Statistical Mechanics · Physics 2011-04-08 Jung-Jung Su , Matthias J. Graf , Alexander V. Balatsky

We present a 3He / 4He dilution refrigerator designed for cooling astronomical mm-wave telescope receivers to around 100 mK. Used in combination with a Gifford-McMahon closed-cycle refrigerator, 4He and 3He sorption-pumped refrigerators,…

Instrumentation and Methods for Astrophysics · Physics 2013-03-21 Simon J. Melhuish , Lorenzo Martinis , Lucio Piccirillo

We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K…

Instrumentation and Detectors · Physics 2015-06-11 Elena Aprile , Ran Budnik , Bin Choi , Hugo Contreras , Karl Giboni , Luke Goetzke , Rafael Lang , Kyungeun Lim , Antonio melgarejo , Petr Shagin