Related papers: Radon Mitigation for the SuperCDMS SNOLAB Dark Mat…
In order to reduce backgrounds from radon-daughter plate-out onto detector surfaces, an ultra-low-radon cleanroom is being commissioned at the South Dakota School of Mines and Technology. An improved vacuum-swing-adsorption radon mitigation…
Long-lived alpha and beta emitters in the $^{222}$Rn decay chain on (and near) detector surfaces may be the limiting background in many experiments attempting to detect dark matter or neutrinoless double-beta decay, and in screening…
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of…
Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of naturally occurring radionuclides K-40, Th-232, U-238, and their progeny in dust. Much effort is…
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials…
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600}…
Radon is one of the most important sources of background in rare event search experiments, such as those searching for Dark Matter and neutrinos, due to its unavoidable production from natural uranium. In low-background experiments, radon…
Low-temperature cryogenics open the door for a range of interesting technologies based on features like superconductivity and superfluidity, low-temperature phase transitions or the low heat capacity of non-metals in the milli-Kelvin range.…
The DAMIC (Dark Matter in CCDs) experiment at the SNOLAB underground laboratory uses fully depleted, high resistivity CCDs to search for dark matter particles with masses below 10 GeV/c$^2$. An upgrade of the detector using an array of…
The DEAP-3600 detector, currently under construction at SNOLAB, has been designed to achieve extremely low background rates from all sources, including 39Ar beta decays, neutron scatters (from internal and external sources), surface alpha…
Radon and its progenies are significant sources of background in rare event detection experiments, including dark matter searches like the PandaX-4T experiment and other rare decay studies such as neutrinoless double beta decay (NLDBD). In…
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction,…
Dark Matter In CCDs (DAMIC) is a silicon detector apparatus used primarily for searching for low-mass dark matter using the silicon bulk of Charge-Coupled Devices (CCDs) as targets. The silicon target within each CCD is…
The decay of common radioactive gases, such as radon, produces stable isotopes by a sequence of daughter particles with varied half-lives. These daughter particles are a significant source of gamma, neutron, and alpha particle backgrounds…
Radon-222 is a limiting background in many leading dark matter and low energy neutrino experiments. One way to mitigate Radon-222 is to fill external experimental components with a clean cover gas such as N2. At the SNOLAB facility in…
The DEAP-3600 experiment is a single-phase detector that uses 3600 Kg of liquid argon to search for Dark Matter at SNOLAB, Sudbury, Canada, 6800 ft. underground. The projected sensitivity to the spin-independent WIMP-nucleon cross-section…
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to…
Polyethylene and copper samples were exposed to the underground air at SNOLAB for approximately three months while several environmental factors were monitored. Predictions of the radon-daughter plate-out rate are compared to the resulting…
The DAMIC experiment employs large-area, thick charge-coupled devices (CCDs) to search for the interactions of low-mass dark matter particles in the galactic halo with silicon atoms in the CCD target. From 2017 to 2019, DAMIC collected data…
The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this,…