Related papers: Intrinsic Resolution of Compton Electrons in CeBr3…
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $\gamma$-ray tagging has been carried out for various radioactive $\gamma$-ray sources. The measured electron…
This study explores the feasibility of using scintillation detectors for muon calorimetry through experiments conducted at CERN's T10 beamline. Results from organic scintillators with varying thicknesses and readout methods, as well as a…
Scintillators attract wide research interest for their distinct applications in radiation detection. Elpasolite halides are among the most promising scintillators due to their high structural symmetry and good scintillation performance.…
The response of a scintillation detector with a cylindrical 1.5-inch LaBr3:Ce crystal to incident neutrons has been measured in the energy range En = 2-12 MeV. Neutrons were produced by proton irradiation of a Li target at Ep = 5-14.6 MeV…
A Compton camera is the most promising approach for gamma-ray detection in the energy region from several hundred keV to MeV, especially for application in high energy astrophysics. In order to obtain good angular resolution, semiconductor…
It was recently shown that the energy resolution of Ce-doped LaBr$_3$ scintillator radiation detectors can be crucially improved by co-doping with Sr, Ca, or Ba. Here we outline a mechanism for this enhancement on the basis of electronic…
We report on a highly selective experimental setup for particle-$\gamma$ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University…
Research in non-perturbative QED in strong-field backgrounds has gained interest in recent years, due to advances in high-intensity laser technologies that make extreme fields accessible in the laboratory. One key signature of strong-field…
X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard…
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier…
LaBr3:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in…
The possibilty of performing high-rate calorimetry with a slow scintillator crystal is studied. In this experimental situation, to avoid pulse pile-up, it can be necessary to base the energy measurement on only a fraction of the emitted…
A novel, non-invasive method of measuring the beam energy at the International Linear Collider is proposed. Laser light collides head-on with beam particles and either the energy of the Compton scattered electrons near the kinematic…
We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid…
The time resolution (TR) is one of the most important characteristic of a detector. For the case of a scintillator, the collection of light also is important, it depends of the effective area of the photo-sensor (\textit{Scorer}). The…
The CLIC Test Facility (CTF3) is an intermediate step to demonstrate the technical feasibility of the key concepts of the new RF power source for CLIC. CTF3 will use electron beams with an energy range adjustable from 170 MeV (3.5 A) to 380…
The nonproportional response and related energy resolution of LaBr$_3$:Ce$^3+$ scintillation crystals doped with different concentrations of cerium were studied between 80K and 450K. For Ce$^3+$ concentration of 5% and 30%, LaBr$_3$ showed…
We investigate the performance of large area radiation detectors, with high energy- and spatial-resolution, intended for the development of a Total Energy Detector with gamma-ray imaging capability, so-called i-TED. This new development…
The uncertainty of the energy measurement of the electron beam on circular electron positron collider (CEPC) must be smaller than 10$\mathrm{MeV}$ to make sure the accurate measurement of the mass of the Higgs boson. In order to simplify…
We propose a new scintillation-type detector in which high-energy radiation produces electron-hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The…