Related papers: Intrinsic Resolution of Compton Electrons in CeBr3…
We proposed a novel method for exploring the intrinsic energy resolution of a liquid scintillator (LAB + 2.5 g/L PPO + 3 mg/L bis-MSB) for approximately 1 MeV electrons. With the help of coincidence detection technology, single-energy…
This study aims to provide an accurate estimation of the intrinsic resolution of LaBr$_3$(Ce) crystal through a combination of experimental and simulation methods. We re-analyzed the data from previous Wide-Angle Compton Coincidence (WACC)…
Using highly monochromatic synchrotron X-rays in the energy range from 10.5 keV to 100 keV the temperature dependence of nonproportionality and energy resolution of LaBr3 scintillators doped with 5% Ce3+ were studied at 80K, 295K, and 450K.…
Localisation of gamma-ray interaction points in monolithic scintillator crystals can simplify the design and improve the performance of a future Compton telescope for gamma-ray astronomy. In this paper we compare the position resolution of…
The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their…
Scintillation detectors are essential tools for radiation measurement, but calibrating them accurately can be challenging, especially when full-energy peaks are not prominent. This is common in detectors like plastic scintillators. Current…
Study of high energy cosmic events in the MeV range requires detector with high efficiency and energy resolution to be constructed. The present setup consisting of scintillator crystals CeBr3 with different thickness, each coupled with 12 x…
The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…
Fluctuations in photon production within scintillators contribute to the overall energy resolution of scintillation detectors. While typically negligible, this contribution - known as intrinsic resolution (IR) - presents significant…
We report on a new measurement of the energy resolution that can be attained in liquid xenon when recording only the scintillation light. Our setup is optimized to maximize light collection, and uses state-of-the-art, high-PDE,…
Fluctuations in photon production in scintillator could contribute to the total energy resolution of a scintillation detector. This contribution, called intrinsic resolution (IR), is one of the factors limiting the total energy resolution…
We have measured the energy dependence of the liquid xenon (LXe) scintillation yield of electrons with energy between 2.1 and 120.2keV, using the Compton coincidence technique. A LXe scintillation detector with a very high light detection…
Energy resolution and the detection efficiency for gamma quanta are fundamental properties in the construction of detectors for ionizing radiation. In this study, a SiPM-based photodetector coupled to a monolithic inorganic CeBr_{3} crystal…
The nonproportional scintillation response of LaBr3 doped with 5% Ce3+ and of LaCl3 doped with 10% Ce3+ was measured using highly monochromatic synchrotron irradiation. To estimate the photon response, pulse height spectra at many finely…
Hard X-ray photons with energies in the range of hundreds of keV typically undergo Compton scattering when they are incident on a detector. In this process, an incident photon deposits a fraction of its energy at the point of incidence and…
The LaBr$_3$(Ce) detector has attracted much attention in recent years for its superior characteristics to other scintillating materials in terms of resolution and efficiency. However, it has relatively high intrinsic radiation background…
Sub-nanometer and nanometer-sized tips provide high coherence electron sources. Conventionally, the effective source size is estimated from the extent of the experimental biprism interference pattern created on the detector by applying the…
In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the…
The properties of large volume cylindrical 3.5 x 8 inches (89 mm x 203 mm) LaBr3:Ce scintillation detectors coupled to the Hamamatsu R10233-100SEL photo-multiplier tube were investigated. These crystals are among the largest ones ever…
We have been developing a semiconductor Compton telescope to explore the universe in the energy band from several tens of keV to a few MeV. We use a Si strip and CdTe pixel detector for the Compton telescope to cover an energy range from 60…