Related papers: Cryogenic readout for multiple VUV4 Multi-Pixel Ph…
Photomultiplier tubes (PMTs) are essential in xenon detectors like PandaX, LZ, and XENON experiments for dark matter searches and neutrino properties measurement. To minimize PMT-induced backgrounds, stringent requirements on PMT…
Accurate detection of quantum states is a vital step in the development of quantum computing. Image-charge detection of quantum states of electrons on liquid helium can potentially be used for the readout of a single-electron qubit;…
In ultraviolet (UV) astronomical observations, photons from the sources are very few compared to the visible or infrared (IR) wavelength ranges. Detectors operating in the UV usually employ a photon-counting mode of operation. These…
Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with…
Photomultiplier tubes (PMTs) are often used in low-background particle physics experiments, which rely on an excellent response to single-photon signals and stable long-term operation. In particular, the Hamamatsu R11410 model is the light…
A highly sensitive photodetection system with a detection limit of 1 photon/s was developed. This system uses a commercially available 200-mm-diameter silicon avalanche photodiode (APD) and an in-house-developed ultralow-noise readout…
PandaX-4T is a dark matter direct detection experiment located in China jinping underground laboratory. The central apparatus is a dual-phase xenon detector containing 4 ton liquid xenon in the sensitive volume, with about 500…
This paper will discuss a new method of signal read-out from photon detectors in ultra-large, underground liquid argon time projection chambers. In this design, the signal from the light collection system is coupled via capacitive plates to…
We present the first operation of the Avalanche Photodiode (APD) from Hamamatsu to xenon scintillation light and to direct X-rays of 22.1 keV and 5.9 keV. A large non-linear response was observed for the direct X-ray detection. At 415 V APD…
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid alternative to standard photomultiplier tubes or large area…
We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated…
This paper reports on the time resolution of two photodetectors operated as single photon counters at high rate: a Hamamatsu R13742-103-M64 "conventional" (based on metal dynodes) multi-anode photomultiplier tube (MaPMT) and a Hamamatsu…
In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts,…
A SensL MicroFC-SMT-60035 6x6 mm$^2$ silicon photo-multiplier coated with a NOL-1 wavelength shifter have been tested in the liquid xenon to detect the 175-nm scintillation light. For comparison, a Hamamatsu vacuum ultraviolet sensitive…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method suggested in the assumption that hidden photons of the mass greater…
CMOS detectors offer many advantages over CCDs for optical and UV astronomical applications, especially in space where high radiation tolerance is required. However, astronomical instruments are most often designed for low light-level…
We describe the development, operation, and application of the 4D Camera -- a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at approximately 480…
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on…
A readout electronics used in space cosmic-ray charges measurement for multi-channel silicon detector and its performance test results are introduced in this paper. A 64-channel charge sensitive ASIC (VA140) from IDEAS company is adopt in…
Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving the best sensitivity for this kind of detectors is crucial for signal identification, leading to…