Related papers: Cryogenic readout for multiple VUV4 Multi-Pixel Ph…
We demonstrate a 64-pixel free-space-coupled array of superconducting nanowire single photon detectors optimized for high detection efficiency in the near-infrared range. An integrated, readily scalable, multiplexed readout scheme is…
We experimentally investigate the performance of NbTiN superconducting nanowire single photon detectors above the base temperature of a conventional Gifford-McMahon cryocooler (2.5 K). By tailoring design and thickness (8 - 13 nm) of the…
We report on the first observation of electroluminescence and charge amplification with a Virtual Cathode Chamber (VCC) microstrips plate immersed in liquid xenon. Both were observed in an intense non-uniform electric field in the vicinity…
Fixed-target experiments using primary electron beams can be powerful discovery tools for light dark matter in the sub-GeV mass range. The Light Dark Matter eXperiment (LDMX) is designed to measure missing momentum in high-rate electron…
Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent…
The performance of a Si PIN diode (type Hamamatsu S3590-06) as an energy sen- sitive detector operating at cryogenic temperatures (~10 K) and in magnetic fields up to 11 T was investigated, using a 207Bi conversion electron source. It was…
Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area…
This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…
We present the precision calibration of 35 Hamamatsu R11410-22 photomultiplier tubes (PMTs) with xenon scintillation light centred near 175 nm. This particular PMT variant was developed specifically for the LUX-ZEPLIN (LZ) dark matter…
There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and successfully tested special designs of gaseous detectors with…
Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field,…
In recent years cooling technology for Liquid Xenon (LXe) detectors has advanced driven by the development of Dark Matter (DM) detectors with target mass in the 100 - 1,000 kg range. The next generation of DM detectors based on LXe will be…
Scalable, high speed data transfer between cryogenic (0.1-4 K) and room temperature environments is instrumental in a broad range of fields including quantum computing, superconducting electronics, single photon imaging and space-based…
Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now…
Panda-X is a liquid xenon dual-phase detector for the Dark Matter Search. The first modestly-sized module will soon be installed in the China JinPing Deep Underground Laboratory in Sichuan province, P.R. China. The cryogenics system is…
We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…
The dark rate of single-electrons emitted from a cathode of a multi-cathode counter may be interpreted as the effect from Hidden Photons (HPs) of Cold Dark Matter (CDM). As a tentative approach the measurements have been performed at…
Liquid argon is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection. SiPM is becoming the standard for scintillator detectors because of its advantages over…
The realization of large-scale photonic circuit for quantum optics experiments at telecom wavelengths requires an increasing number of integrated detectors. Superconductive nanowire single photon detectors (SNSPDs) can be easily integrated…
The Medipix4 chip is the latest member in the Medipix/Timepix family of hybrid pixel detector chips aimed at high-rate spectroscopic X-ray imaging using high-Z materials. It can be tiled on all 4 sides making it ideal for constructing…