Related papers: High Spatial-Resolution Fast Neutron Detectors for…
The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron…
Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. In general the absorption in the typical studied materials can be neglected and this technique is limited to the measurement of the reflectivity only. In…
Uncertainties in the proton range in tissue during proton therapy limit the precision in treatment delivery. These uncertainties result in expanded treatment margins, thereby increasing radiation dose to healthy tissue. Real-time range…
Recording of transient absorption microscopy images requires fast detection of minute optical density changes, which is typically achieved with high-repetition-rate laser sources and lock-in detection. Here, we present a highly flexible and…
A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV…
All optical detectors to date annihilate photons upon detection, thus excluding repeated measurements. Here, we demonstrate a robust photon detection scheme which does not rely on absorption. Instead, an incoming photon is reflected off an…
Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe…
In recent years, demand for scintillation detectors with high time resolution (better than 100 ps) has emerged in high-energy physics and medical imaging applications. In particular, time of flight positron emission tomography (TOF-PET) can…
Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…
The HGND (High Granular Neutron Detector) is developed for the BM@N (Baryonic Matter at Nuclotron) experiment on the extracted beam of the Nuclotron at JINR, Dubna. The HGND will be used to measure the azimuthal flow of neutrons produced…
We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and $^3$He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few…
A new measurement of the $^{235}$U(n,f) cross section was performed at the neutron time-of-flight facility n_TOF at CERN. The experiment focused on neutron energies from 20 MeV to several hundred MeV, and was normalized to neutron…
The measurement of environmental neutrons is particularly important in the search for new physics, such as dark matter particles, because neutrons constitute an often-irreducible background source. The measurement of the neutron energy…
We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements.…
Fast variability of optical objects is an interesting though poorly explored subject in modern astronomy. Real-time data processing and identification of transient celestial events in the images is very important for such study as it allows…
We present the design and the absolute calibration of charged particle high-repetition-rate online readout CMOS system tailored for high-power laser experiments. This system equips a Thomson parabola (TP) spectrometer, used at the Apollon…
In a previous work we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the…
The basic principles of detection of fast neutrons with liquid scintillator detectors are reviewed, together with a real example in the form of the Neutron Wall array. Two of the challenges in neutron detection, discrimination of neutrons…
The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape…
The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the…