English
Related papers

Related papers: Cryomodule Test Stand Reduced-Magnetic Support Des…

200 papers

The Proton Improvement Plan-II (PIP-II) is a major upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (Linac) powering the accelerator complex to provide the world's…

Accelerator Physics · Physics 2023-08-23 A Martinez , J Creus Prats , W Soyars , R Dhuley , B Hansen , Y Jia , A Chakravarty , M Goyal , T Banaszkiewicz , P Duda , M Stanclik

We have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The…

The parameters for a 30 GeV test beam are outlined for use with an undulator in the FFTB tunnel where the LCLS will eventually be housed. It is proposed to use the SLAC linac and damping rings in their present mode of operation for PEP II…

Accelerator Physics · Physics 2007-05-23 Patrick Krejcik

Fermi National Accelerator Laboratory (FNAL) and Lawrence Berkeley National Laboratory (LBNL) are building a new High Field Vertical Magnet Test Facility (HFVMTF) for testing superconducting cables in high magnetic field. The background…

The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause…

The Muon g-2 Experiment (E989) at Fermilab is seeking to measure the anomalous magnetic moment of muon ($a_{\mu}$) with a precision of 140 parts-per-billion (ppb) and aiming to resolve the discrepancy between the E821 measurement and the…

Instrumentation and Detectors · Physics 2018-10-10 Ran Hong

The position noise spectra of six drums on a single chip were measured on a single cooldown below 1.3 kelvin. Cryostat temperatures as low as 0.7 mK were achieved. The temperature dependence of the resonance frequency and linewidth of the…

Mesoscale and Nanoscale Physics · Physics 2026-02-26 Amir Youssefi , Mahdi Chegnizadeh , Francis Bettsworth , Richard Pedurand , Eddy Collin , Tobias J. Kippenberg , Andrew Fefferman

Muon ionization cooling provides the only practical solution to prepare high-brilliance beams necessary for a neutrino factory or muon collider. The Muon Ionization Cooling Experiment (MICE), under development at the Rutherford Appleton…

Accelerator Physics · Physics 2008-10-11 Terrence L. Hart , Daniel M. Kaplan

For the CLIC two-beam scheme, a high-current, long-pulse drive beam is required for RF power generation. Taking advantage of the 3 GHz klystrons available at the LEP injector once LEP stops, a 180 MeV electron accelerator is being…

Accelerator Physics · Physics 2007-05-23 G. Carron , E. Jensen , M. Luong , A. Millich , E. Rugo , I. Syratchev , L. Thorndahl

The SPLENDOR Collaboration studies novel narrow-gap semiconductors and engineered a substrate agnostic detector platform to achieve $\mathcal{O}$(meV) energy sensitivity designed for low mass dark matter searches. This was achieved using…

Instrumentation and Detectors · Physics 2025-10-03 Jadyn Anczarski , Owen Andrews , Taylor Aralis , Caleb Fink , Noah Kurinsky , Arran Phipps , Aditi Pradeep , Betty A. Young

We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10$^{-16}\, \mathrm{m/\sqrt{Hz}}$ at 1kHz. A volume of $\sim$36 litres…

Instrumentation and Detectors · Physics 2025-08-28 D. P. Kapasi , T. G. McRae , J. Eichholz , P. A. Altin , D. E. McClelland , B. J. J. Slagmolen

The next generation of high-energy physics experiments requires high intensity protons in the multi-GeV energy range for efficient production of secondary beams. The Fermilab long-term future requires an 8 GeV proton source to feed the Main…

Accelerator Physics · Physics 2012-03-09 L. Jenner , C. Johnstone , D. Neuffer , J. Pasternak

The off-frequency detune method is being considered for application in the LCLS-II-HE superconducting linac to produce multi-energy electron beams for supporting multiple undulator lines simultaneously [1]. Design of the tuner has been…

Accelerator Physics · Physics 2022-08-10 Y. Pischalnikov , T. Arkan , C. Contreras-Martinez , B. Hartsell , J. Kaluzny , R. Pilipenko , J. C. Yun , W. Lahmadi

The present article introduces a novel ASIC architecture, designed in the context of the ATLAS Tile Calorimeter upgrade program for the High-Luminosity phase of the Large Hadron Collider at CERN. The architecture is based on…

The DarkSide-20k experiment represents the present goal of the Global Argon Dark Matter Collaboration program. Bringing together the experience from previous argon-based detectors, as well as the knowledge gained on large volume membrane…

Instrumentation and Detectors · Physics 2025-12-01 Andrea Zani

The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be…

This paper evaluates the radiation tolerance of commercial off-the-shelf (COTS) electronics components for use in the Thin Gap Chamber (TGC) frontend electronics of the ATLAS experiment at the High-Luminosity LHC (HL-LHC). The ATLAS…

Field emission (FE) is one of the main limiting factors of superconducting radio-frequency (SRF) cavities operating in accelerators and it occurs whenever contaminants, like dust, metal flakes or even absorbates, are present on the surface…

Superconducting radio-frequency cavities are commonly used in modern particle accelerators for applied and fundamental research. Such cavities are typically made of high-purity, bulk Nb and are cooled by a liquid helium bath at a…

Instrumentation and Detectors · Physics 2020-06-24 G. Ciovati , G. Cheng , U. Pudasaini , R. Rimmer

A number of critical active and passive components of optical links have been tested at 77 K or lower temperatures, demonstrating potential development of optical links operating inside the liquid argon time projection chamber (LArTPC)…