English
Related papers

Related papers: Gas gap studies about streamer operated RPCs

200 papers

The present paper is meant as an update of the presentation given in a previous Resistive Plate Chamber (RPC) workshop, aimed at finding an eco-friendly gas mixture for streamer operation of RPCs. Indeed the streamer working regime is still…

Instrumentation and Detectors · Physics 2019-09-04 A. Paoloni , A. Mengucci , M. Spinetti , M. Ventura , L. Votano

The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were…

Instrumentation and Detectors · Physics 2020-01-29 R. Cardarelli , G. Aielli , E. Alunno Camelia , S. Bruno , A. Caltabiano , P. Camarri , A. Di Ciaccio , B. Liberti , L. Massa , L. Pizzimento , A. Rocchi

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…

Instrumentation and Detectors · Physics 2016-08-03 G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , R. Iuppa , B. Liberti , L. Paolozzi , E. Pastori , R. Santonico , M. Toppi

This work has been carried out to simulate a Resistive Plate Chamber and corroborate it with experimental measurements in order to develop a numerical tool for studying the performance of the device for any gas mixture. This will allow us…

Instrumentation and Detectors · Physics 2021-02-03 Jaydeep Datta , Sridhar Tripathy , Nayana Majumdar , Supratik Mukhopadhyay

A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…

Instrumentation and Detectors · Physics 2021-11-30 Yousef Pezeshkian , Amir Kiyoumarsioskouei , Majid Ahmadpouri , Ghasem Ghorbani

This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement…

Instrumentation and Detectors · Physics 2022-05-18 G. Proto , B. Liberti , R. Santonico , G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , A. Paoloni , E. Pastori , L. Pizzimento , A. Rocchi

Resistive gaseous detectors can be broadly defined as those operated in conditions where virtually no field lines exist that connect any two metallic electrodes sitting at different potential. This condition can be operationally recognized…

Instrumentation and Detectors · Physics 2015-06-05 Diego Gonzalez-Diaz , Archana Sharma

Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…

Instrumentation and Detectors · Physics 2022-11-30 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes

The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The…

Instrumentation and Detectors · Physics 2021-08-31 Quanyin Li , Xiangyu Xie , Zhengwei Xue , Jiajin Ge , Yongjie Sun

The standard gas mixture for the Resistive Plate Chambers (RPC), composed of C2H2F4/i-C4H10/SF6, allows the detector operation in avalanche mode, as required by the high-luminosity collider experiments. The gas density, the low current and…

Instrumentation and Detectors · Physics 2025-03-10 Giorgia Proto

Resistive Plate Chambers (RPCs) have traditionally operated with high Global Warming Potential (GWP) gas mixtures, adding to the environmental footprint of large-scale physics experiments. In response, efforts are underway to explore…

Instrumentation and Detectors · Physics 2025-06-23 Aashaq Shah , Thomas Adolphus , Yingchang Zhang , Oleg Brandt

Gaseous detectors have long been used by particle physics experiments at beamlines or standalone experiments. Recently, their low momentum threshold has made them interesting as active targets for long baseline neutrino experiments. To…

Instrumentation and Detectors · Physics 2019-11-13 Philip Hamacher-Baumann

The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…

The ATLAS Muon Spectrometer is undergoing a major upgrade for the High-Luminosity LHC (HL-LHC), including the addition of three new thin-gap Resistive Plate Chamber (RPC) layers in the inner barrel region. These RPCs have 1 mm gas gaps…

Instrumentation and Detectors · Physics 2025-01-10 F. Fallavollita , O. Kortner , H. Kroha , P. Maly , G. Proto , D. Soyk , E. Voevodina , J. Zimmermann

In this work we describe some recent results concerning the application of Resistive Plate Chambers operated in avalanche mode at atmospheric pressure for high-resolution time-of-flight measurements. A combination of multiple, mechanically…

Instrumentation and Detectors · Physics 2009-11-07 P. Fonte , V. Peskov

Resistive Plate Chamber detectors are largely used in current High Energy Physics experiments, typically operated in avalanche mode with large fractions of Tetrafluoroethane (C2H2F4), a gas recently banned by the European Union due to its…

Instrumentation and Detectors · Physics 2024-10-16 Luca Quaglia

In this paper we propose a new concept for streamer quenching in Resistive Plate Chambers (RPCs). In our approach, the multiplication process is quenched by the appropriate design of a mechanical structure inserted between the two resistive…

Instrumentation and Detectors · Physics 2010-11-11 A. Calcaterra , R. de Sangro , G. Mannocchi , P. Patteri , P. Picchi , M. Piccolo , N. Redaelli , T. Tabarelli de Fatis , G. C. Trinchero

In work the results of the analysis are presented relating to the status of a streamer discharge mode in different gas detectors developed at the moment in laboratories and nuclear-physics installations. Thanks to new representations from a…

Instrumentation and Detectors · Physics 2012-09-19 V. I. Razin

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , A. Smirnitskiy , K. Voloshin
‹ Prev 1 2 3 10 Next ›