Related papers: Study of the Crosstalk Evaluation for Cavity BPM
The undulator line of the Shanghai soft X-ray Free-electron Laser facility (SXFEL) has very tight tolerances on the straightness of the electron beam trajectory. However, the beam trajectory cannot meet the lasing requirements due to the…
The efficiency of beam injection in circular accelerators can be impacted by unknown aperture limitations in the vacuum chamber. These limitations can be detected by introducing localized distortions to the closed orbit of the circulating…
This article presents a thorough comparison of themain QPM techniques, focusing on their accuracy in terms of measurement precision and trueness. We focus on 8 techniques, namely digital holographic microscopy (DHM), cross-grating wavefront…
Cavity-based x-ray free-electron lasers (CBXFEL) will allow use of optical cavity feedback to support generation of fully coherent x-rays of high brilliance and stability by electrons in undulators. CBXFEL optical cavities comprise…
In a linac driven Free Electron Laser (FEL), the shot-to-shot and non-invasive monitoring of the electron bunch length is normally ensured by Bunch Compressor Monitors (BCMs). The bunch-length dependent signal of a BCM results from the…
The fields produced by a long beam with a given transverse charge distribution in a homogeneous vacuum chamber are studied. Signals induced by a displaced finite-size beam on electrodes of a beam position monitor (BPM) are calculated and…
We report the design, operation and performance of a high-resolution, low-latency, bunch-by-bunch feedback system for nano-beam stabilisation. The system employs novel, ultra-low quality-factor cavity beam position monitors (BPMs), a…
Measurement for qubits plays a key role in quantum computation. Current methods for classifying states of single qubit in a superconducting multi-qubit system produce fidelities lower than expected due to the existence of crosstalk,…
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of…
The new beam position monitor (BPM) system of the injector at the upgrade project of Hefei Light Source (HLS II) has 19 stripline beam position monitors. Most consist of four orthogonal symmetric stripline electrodes. The differences in…
Soaring demands of multi-stacked memory devices request urgent development of backside contact electrode technologies, such as high aspect ratio etching, metallization, and inspection methods. Especially the complex metal contact process…
The control of beam phase relative to the accelerating RF field within a superconducting cavity is important in many accelerator applications and is of particular importance for a free electron laser facility. As standard practice, the…
Several optomechanics experiments are now entering the highly sought nonlinear regime where optomechanical interactions are large even for low light levels. Within this regime, new quantum phenomena and improved performance may be achieved,…
The ray dynamics of optical cavities exhibits bifurcation points: special geometries at which ray trajectories switch abruptly between stable and unstable. A prominent example is the Fabry-Perot cavity with two planar mirrors, which is…
We propose and experimentally demonstrate a method for non-invasive measurements of cavity parameters by injection of squeezed vacuum into an optical cavity. The principle behind this technique is the destruction of the correlation between…
A common-mode free cavity BPM is currently under development at Fermilab within the ILC-CLIC collaboration. This monitor will be operated in a CLIC Main Linac multi-bunch regime, and needs to provide both, high spatial and time resolution.…
Multi-spectral quantitative phase imaging (QPI) is an emerging imaging modality for wavelength dependent studies of several biological and industrial specimens. Simultaneous multi-spectral QPI is generally performed with color CCD cameras.…
We couple a double-channel imaging technique, allowing for the simultaneous acquisition of high-quality and high-resolution intensity and peak emission wavelength profiles [T. Wang and G.L. Lippi, Rev. Sci. Instr. 86, 063111 (2015)], to the…
We present a novel method of calibration of crosstalk probability for multi-pixel photon counters (MPPCs) based on the measurement of the normalized second-order intensity correlation function of coherent light. The method was tested for…
In spite of extensive observations and numerous theoretical studies in the past decades several key questions related with Gamma-Ray Bursts (GRB) emission mechanisms are still to be answered. Precise detection of the GRB polarization…