English
Related papers

Related papers: Study of the Crosstalk Evaluation for Cavity BPM

200 papers

Diagnosing free electron laser (FEL) polarization is critical for polarization-modulated research such as x-ray free electron laser (XFEL) diffraction imaging and probing material magnetism. In an electron time-of-flight (eTOF)\…

Instrumentation and Detectors · Physics 2021-11-24 Zipeng Liu , Bangjie Deng , Haixiao Deng , Bo Liu

Beam position monitor (BPM) can easily reinforce the handling of beam orbits and measure the absolute beam position [1]. Its data can be used to optimize and correct beam in both first turn and closed orbit mode. In order to set the…

Accelerator Physics · Physics 2019-08-17 Jiandong Yuan , Lizhen Ma , Bin Zhang , Junjie Yao

In superconducting linear accelerators (linacs), accurately monitoring beam dynamics is essential for minimizing beam losses and ensuring stable operations. However, destructive diagnostics must be avoided in superconducting sections to…

The direct response of Silicon PhotoMultipliers being traversed by a MIP charged particle have been studied in a systematic way for the first time. Using beam test data, time resolution and the crosstalk probability have been measured. A…

IP-BPM (Interaction Point Beam Position Monitor) is an ultra high resolution cavity BPM to be used at ATF2, a test facility for ILC final focus system. Control of beam position in 2 nm precision is required for ATF2. Beam tests at ATF…

An electron beam entering an accelerator cavity excites higher order modes (HOM). These are radiated to HOM couplers and subsequently damped. They can also be used to facilitate beam position monitoring. The modes excited by off-axis beams…

Accelerator Physics · Physics 2011-05-24 P. Zhang , N. Baboi , H. Ecklebe , T. Flisgen , H. W. Glock , R. M. Jones , B. Lorbeer , I. R. R. Shinton

High-fidelity mid-circuit measurements, which read out the state of specific qubits in a multiqubit processor without destroying them or disrupting their neighbors, are a critical component for useful quantum computing. They enable…

Quantum Physics · Physics 2024-10-23 Daniel Hothem , Jordan Hines , Charles Baldwin , Dan Gresh , Robin Blume-Kohout , Timothy Proctor

Length and g-factor are fundamental parameters that characterize optical cavities. We developed a technique to measure these parameters in-situ by determining the frequency spacing between the resonances of fundamental and spatial modes of…

Optics · Physics 2015-06-05 Alberto Stochino , Koji Arai , Rana X. Adhikari

Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated…

Accelerator Physics · Physics 2012-10-16 Nicoleta Baboi , Bastian Lorbeer , Pei Zhang , Nathan Eddy , Brian Fellenz , Manfred Wendt

Commercial atomic force microscopes usually use a four-segmented photodiode to detect the motion of the cantilever via laser beam deflection. This read-out technique enables to measure bending and torsion of the cantilever separately. A…

Materials Science · Physics 2009-11-11 A. Hoffmann , T. Jungk , E. Soergel

Optical beam center position on an array of detectors is an important (hidden) parameter that is essential not only from a tracking perspective, but is also important for optimal detection of Pulse Position Modulation symbols in free-space…

Signal Processing · Electrical Eng. & Systems 2020-01-14 Muhammad Salman Bashir , Mohamed-Slim Alouini

This introduction on beam position monitors (BPM) summarizes the fundamental parts of the tutorial presented at the CAS 2018 on beam instrumentation. The focus is on the signal detection and normalization, and on the principle of operation…

Accelerator Physics · Physics 2020-06-03 M. Wendt

With a Bayesian Gaussian regression approach, a systematic method for analyzing a storage ring's beam position monitor (BPM) system requirements has been developed. The ultimate performance of a ring-based accelerator, based on brightness…

Accelerator Physics · Physics 2019-07-15 Yongjun Li , Yue Hao , Weixing Cheng , Robert Rainer

This paper presents a study of beam alignment in accelerating cavities based on beam-excited higher order modes (HOM). Among the transverse HOMs, dipole modes have the dominant contribution, and may have an adverse effect on the beam…

Accelerator Physics · Physics 2011-11-16 P. Zhang , N. Baboi , R. M. Jones

This study is focused on the development of a HOM-based BPM system for the ACC39 module currently installed and in operation at FLASH. A similar system is anticipated to be installed at XFEL. Coupled inter-cavity modes are simulated…

Accelerator Physics · Physics 2012-05-22 I. R. R. Shinton , R. M. Jones , Z. Li , P. Zhang

It is usually considered that the spectrum of an optical cavity coupled to an atomic medium does not exhibit a normal-mode splitting unless the system satisfies the strong coupling condition, meaning the Rabi frequency of the coherent…

Quantum Physics · Physics 2017-01-06 Y. -H. Lien , G. Barontini , M. Scheucher , M. Mergenthaler , J. Goldwin , E. A. Hinds

A simple, analytically correct algorithm is developed for calculating pencil beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The…

Accelerator Physics · Physics 2018-05-23 P. Thieberger , D. Gassner , R. Hulsart , R. Michnoff , T. Miller , M. Minty , Z. Sorrell , A. Bartnik

Measurements of ultrahigh-fidelity absorption spectra can help validate quantum theory, engineer ultracold chemistry, and remotely sense atmospheres. Recent achievements in cavity-enhanced spectroscopy using either frequency-based…

Optics · Physics 2020-01-24 A. Cygan , A. J. Fleisher , R. Ciuryło , K. A. Gillis , J. T. Hodges , D. Lisak

We propose and demonstrate a new scheme for atom interferometry, using light pulses inside an optical cavity as matter wave beamsplitters. The cavity provides power enhancement, spatial filtering, and a precise beam geometry, enabling new…

The Qweak experiment aims to measure the weak charge of the proton to 4% via the parity-violating asymmetry ($\sim$-200 ppb) in elastic e+p scattering. The scattering rate is largely influenced by five beam parameters: horizontal position…

Accelerator Physics · Physics 2015-06-11 Nuruzzaman