English
Related papers

Related papers: Characterization of the previous normal-dose CT sc…

200 papers

Low-dose CT imaging requires reconstruction from noisy indirect measurements which can be defined as an ill-posed linear inverse problem. In addition to conventional FBP method in CT imaging, recent compressed sensing based methods exploit…

Image and Video Processing · Electrical Eng. & Systems 2025-11-14 Mehmet Ozan Unal , Metin Ertas , Isa Yildirim

Regularization methods are commonly used in X-ray CT image reconstruction. Different regularization methods reflect the characterization of different prior knowledge of images. In a recent work, a new regularization method called a…

Medical Physics · Physics 2017-04-18 Wenxiang Cong , Ge Wang , Qingsong Yang , Jiang Hsieh , Jia Li , Rongjie Lai

Low-dose computed tomography (LDCT) offers significant advantages in reducing the potential harm to human bodies. However, reducing the X-ray dose in CT scanning often leads to severe noise and artifacts in the reconstructed images, which…

Image and Video Processing · Electrical Eng. & Systems 2024-08-27 Ran An , Yinghui Zhang , Xi Chen , Lemeng Li , Ke Chen , Hongwei Li

Low-dose computed tomography (LDCT) reduces patient radiation exposure but introduces substantial noise that degrades image quality and hinders diagnostic accuracy. Existing denoising approaches often require many diffusion steps, limiting…

Medical Physics · Physics 2025-10-29 Qiang Li , Mojtaba Safari , Shansong Wang , Huiqiao Xie , Jie Ding , Tonghe Wang , Xiaofeng Yang

Low-dose Computed Tomography (LDCT) reconstruction is an important task in medical image analysis. Recent years have seen many deep learning based methods, proved to be effective in this area. However, these methods mostly follow a…

Image and Video Processing · Electrical Eng. & Systems 2023-02-08 Runyi Li

Low-dose computed tomography (LDCT) is the standard modality for lung cancer screening, known for its low radiation dose but high noise levels. While existing literature focuses on denoising LDCT images, comparative research on simulating…

Image and Video Processing · Electrical Eng. & Systems 2026-05-13 Jiaying Liu , Anna Corti , Valentina D. A. Corino , Luca Mainardi

The resurgence of deep neural networks has created an alternative pathway for low-dose computed tomography denoising by learning a nonlinear transformation function between low-dose CT (LDCT) and normal-dose CT (NDCT) image pairs. However,…

Image and Video Processing · Electrical Eng. & Systems 2022-11-04 Sutanu Bera , Prabir Kumar Biswas

In this paper we present a generalized Deep Learning-based approach for solving ill-posed large-scale inverse problems occuring in medical image reconstruction. Recently, Deep Learning methods using iterative neural networks and cascaded…

Image and Video Processing · Electrical Eng. & Systems 2020-08-26 Andreas Kofler , Markus Haltmeier , Tobias Schaeffter , Marc Kachelrieß , Marc Dewey , Christian Wald , Christoph Kolbitsch

Low-Dose Computed Tomography (LDCT) technique, which reduces the radiation harm to human bodies, is now attracting increasing interest in the medical imaging field. As the image quality is degraded by low dose radiation, LDCT exams require…

Image and Video Processing · Electrical Eng. & Systems 2022-04-19 Liutao Yang , Zhongnian Li , Rongjun Ge , Junyong Zhao , Haipeng Si , Daoqiang Zhang

Low-Dose computer tomography (LDCT) is an ideal alternative to reduce radiation risk in clinical applications. Although supervised-deep-learning-based reconstruction methods have demonstrated superior performance compared to conventional…

Image and Video Processing · Electrical Eng. & Systems 2024-05-24 Feng Wang , Renfang Wang , Hong Qiu

Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image…

Image and Video Processing · Electrical Eng. & Systems 2023-10-12 Wenjun Xia , Yongyi Shi , Chuang Niu , Wenxiang Cong , Ge Wang

Low Dose Computed Tomography suffers from a high amount of noise and/or undersampling artefacts in the reconstructed image. In the current article, a Deep Learning technique is exploited as a regularization term for the iterative…

Image and Video Processing · Electrical Eng. & Systems 2019-06-04 Shabab Bazrafkan , Vincent Van Nieuwenhove , Joris Soons , Jan De Beenhouwer , Jan Sijbers

The application of ionizing radiation for diagnostic imaging is common around the globe. However, the process of imaging, itself, remains to be a relatively hazardous operation. Therefore, it is preferable to use as low a dose of ionizing…

Image and Video Processing · Electrical Eng. & Systems 2023-11-01 A. Demir , M. M. A. Shames , O. N. Gerek , S. Ergin , M. Fidan , M. Koc , M. B. Gulmezoglu , A. Barkana , C. Calisir

Reducing the radiation exposure for patients in Total-body CT scans has attracted extensive attention in the medical imaging community. Given the fact that low radiation dose may result in increased noise and artifacts, which greatly…

Image and Video Processing · Electrical Eng. & Systems 2023-07-19 Minghan Fu , Yanhua Duan , Zhaoping Cheng , Wenjian Qin , Ying Wang , Dong Liang , Zhanli Hu

Computed Tomography (CT) is a vital diagnostic tool in clinical practice, yet the health risks associated with ionizing radiation cannot be overlooked. Low-dose CT (LDCT) helps mitigate radiation exposure but simultaneously leads to reduced…

Computer Vision and Pattern Recognition · Computer Science 2025-11-20 Guoliang Gong , Man Yu

Multi-energy CT takes advantage of the non-linearly varying attenuation properties of elemental media with respect to energy, enabling more precise material identification than single-energy CT. The increased precision comes with the cost…

Medical Physics · Physics 2020-02-14 Jussi Toivanen , Alexander Meaney , Samuli Siltanen , Ville Kolehmainen

As the medical usage of computed tomography (CT) continues to grow, the radiation dose should remain at a low level to reduce the health risks. Therefore, there is an increasing need for algorithms that can reconstruct high-quality images…

Image and Video Processing · Electrical Eng. & Systems 2021-03-10 Davood Karimi , Rabab K. Ward

X-ray Computed Tomography (CT) is an important tool in medical imaging to obtain a direct visualization of patient anatomy. However, the x-ray radiation exposure leads to the concern of lifetime cancer risk. Low-dose CT scan can reduce the…

Medical Physics · Physics 2018-10-30 Guoyang Ma , Chenyang Shen , Xun Jia

Image reconstruction from computed tomography (CT) measurement is a challenging statistical inverse problem since a high-dimensional conditional distribution needs to be estimated. Based on training data obtained from high-quality…

Image and Video Processing · Electrical Eng. & Systems 2020-06-12 Alexander Denker , Maximilian Schmidt , Johannes Leuschner , Peter Maass , Jens Behrmann

X-ray computed tomographic infrastructures are medical imaging modalities that rely on the acquisition of rays crossing examined objects while measuring their intensity decrease. Physical measurements are post-processed by mathematical…

Image and Video Processing · Electrical Eng. & Systems 2022-01-25 Attila Juhos
‹ Prev 1 2 3 10 Next ›