English
Related papers

Related papers: An ultra-sensitive and wideband magnetometer based…

200 papers

We present the prototype module of our extendible and robust multichannel SQUID magnetometer system. A multi-module arrangement can be implemented by using up to 7 modules. It is intended for high-precision measurements of biomagnetism and…

Instrumentation and Detectors · Physics 2017-08-29 Jan-Hendrik Storm , Dietmar Drung , Martin Burghoff , Rainer Körber

The requirements for the construction of ultra-sensitive SQUID instrumentation as used in biomagnetism are presented. Typically, SQUIDs are inductively coupled to pick-up coils and for this arrangement one can improve the noise performance…

Instrumentation and Detectors · Physics 2019-03-25 Rainer Körber

Superconducting QUantum-Interference Devices (SQUIDs) make magnetic resonance imaging (MRI) possible in ultra-low microtesla-range magnetic fields. In this work, we investigate the design parameters affecting the signal and noise…

Instrumentation and Detectors · Physics 2020-01-16 Koos C. J. Zevenhoven , Antti J. Mäkinen , Risto J. Ilmoniemi

We report on a scanned superconducting quantum interference device (SQUID) microscope operating in a cryogen-free cryostat, with the capability of up to forty RF connections with 20 GHz bandwidth to a device under test. The system utilizes…

Superconductivity · Physics 2025-09-10 Ian W. Haygood , Bochao Xu , John Biesecker , Michael L. Schneider

There is currently fundamental and technological interest in measuring and manipulating nanoscale magnets, particularly in the quantum coherent regime. To observe the dynamics of such systems one requires a magnetometer with not only…

Mesoscale and Nanoscale Physics · Physics 2015-05-18 M. Hatridge , R. Vijay , D. H. Slichter , J. Clarke , I. Siddiqi

We report the fabrication of a directly coupled superconducting quantum interference device (SQUID) magnetometer in MgB2 using a focused ion beam (FIB) to create Josephson junctions in a 70 nm thick film of MgB2. The SQUID shows a voltage…

Superconductivity · Physics 2009-11-07 G. Burnell , D. -J. Kang , D. A. Ansell , H. -N. Lee , S. -H. Moon , E. J. Tarte , M. G. Blamire

A novel setup for the measurement of magnetic fields external to certain antiferromagnets and generally weakly remanent magnetic materials is presented. The setup features a highly sensitive Super Conducting Quantum Interference Device…

We investigated, at temperature $4.2\,\mathrm{K}$, electric transport, flux noise and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions…

Superconductivity · Physics 2015-05-28 J. Nagel , O. F. Kieler , T. Weimann , R. Wölbing , J. Kohlmann , A. B. Zorin , R. Kleiner , D. Koelle , M. Kemmler

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the…

We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a…

Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used…

Instrumentation and Detectors · Physics 2026-01-29 Nan Li , Mengjie Song , Sixiao Hu , Wentao Wu , Songqing Liu , Tangchong Kuang , Yudong Gu , Xiangxiang Ren , Xufang Li , He Gao , Zhengwei Li , Congzhan Liu

The magnetic sensing at nanoscale level is a promising and interesting research topic of nanoscience. Indeed, magnetic imaging is a powerful tool for probing biological, chemical and physical systems. The study of small spin cluster, like…

Superconductivity · Physics 2016-01-12 Carmine Granata , Antonio Vettoliere

SQUID systems for ultra-low-field magnetic resonance (ULF MR) feature superconducting pick-up coils which must tolerate exposure to pulsed fields of up to 100 mT. Using type-II superconductor niobium (Nb) field distortions due to trapped…

Superconductivity · Physics 2018-01-29 Eva Al-Dabbagh , Jan-Hendrik Storm , Rainer Körber

We designed and fabricated a new type of superconducting quantum interference device (SQUID) susceptometers for magnetic imaging of quantum materials. The 2-junction SQUID sensors employ 3D Nb nano-bridges fabricated using electron beam…

Mesoscale and Nanoscale Physics · Physics 2019-05-22 Y. P. Pan , S. Y. Wang , X. Y. Liu , Y. S. Lin , L. X. Ma , Y. Feng , Z. Wang , L. Chen , Y. H. Wang

We report on the development of an ultralow noise thin-film based SQUID magnetometer. A niobium thin-film pickup coil is connected to the input coil of a SQUID current sensor. The low capacitance of the used sub-micrometer cross-type…

Instrumentation and Detectors · Physics 2017-05-18 M. Schmelz , V. Zakosarenko , A. Chwala , T. Schönau , R. Stolz , S. Anders , S. Linzen , H. -G. Meyer

We present results on ultra low noise YBa$_2$Cu$_3$O$_{7-\delta}$ nano Superconducting QUantum Interference Devices (nanoSQUIDs). To realize such devices, we implemented high quality YBCO nanowires, working as weak links between two…

Superconductivity · Physics 2014-03-07 Riccardo Arpaia , Marco Arzeo , Shahid Nawaz , Sophie Charpentier , Floriana Lombardi , Thilo Bauch

Superconducting quantum interference devices (SQUIDs) are among the most sensitive detectors for out-of-plane magnetic field components. However, due to their periodic response with short modulation period $M = 1 \Phi_0$, determined by the…

We present measurements of an amplifier operating at 3.8 GHz with 150 MHz of bandwidth based on the microstrip input-coil resonance of a dc superconducting quantum interference device (SQUID) with submicron Josephson junctions. The noise…

Superconductivity · Physics 2015-06-05 M. P. DeFeo , B. L. T. Plourde

We report a scanning superconducting quantum interference device (SQUID) microscope in a cryogen-free dilution refrigerator with a base temperature at the sample stage of at least 30 mK. The microscope is rigidly mounted to the mixing…

Mesoscale and Nanoscale Physics · Physics 2021-09-15 D. Low , G. M. Ferguson , Alexander Jarjour , Brian T. Schaefer , Maja D. Bachmann , Philip J. W. Moll , Katja C. Nowack

The superconducting quantum interference device (SQUID) magnetometer is one of the most sensitive experimental techniques to magnetically characterize samples with high sensitivity. Here we present a detailed discussion of possible…

Materials Science · Physics 2015-05-27 M. Sawicki , W. Stefanowicz , A. Ney
‹ Prev 1 2 3 10 Next ›