English
Related papers

Related papers: An ultra-sensitive and wideband magnetometer based…

200 papers

We demonstrate a superconducting inductive technique to measure the displacement of a micromechanical resonator. In our scheme, a type I superconducting microsphere is attached to the free end of a microcantilever and approached to the loop…

Mesoscale and Nanoscale Physics · Physics 2016-01-08 Andrea Vinante

Here we present a multichannel system based on superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG) measurements, developed and installed at Istituto di Cibernetica (ICIB) in Naples. This MEG system,…

Medical Physics · Physics 2013-10-18 S Rombetto , C Granata , A Vettoliere , A Trebeschi , R Rossi , M Russo

An increasing number of experiments require the use of ultrasensitive nanomechanical resonators. Relevant examples are the investigation of quantum effects in mechanical systems [1] or the detection of exceedingly small forces as in…

Instrumentation and Detectors · Physics 2010-07-12 O. Usenko , A. Vinante , G. Wijts , T. H. Oosterkamp

We have fabricated arrays of High-T$_c$ Superconducting Quantum Interference Devices (SQUIDs) with randomly distributed loop sizes as sensitive antennas for Radio-Frequency (RF) waves. These sub-wavelength size devices known as…

We have developed a nuclear magnetic resonance spectrometer with a series tuned input circuit for measurements on samples at millikelvin temperatures based on an integrated two-stage superconducting quantum interference device current…

Superconductivity · Physics 2009-11-13 L. V. Levitin , R. G. Bennett , A. Casey , B. P. Cowan , C. P. Lusher , J. Saunders , D. Drung , Th. Schurig

We developed a scanning DC SQUID microscope with novel readout electronics capable of wideband sensing RF magnetic fields from 50 to 200 MHz and simultaneously providing closed-loop response at kHz frequencies. To overcome the 20 MHz…

Scanning superconducting quantum interference device microscopy (sSQUID) is currently one of the most effective methods for direct and sensitive magnetic flux imaging on the mesoscopic scale. A SQUID-on-chip design allows integration of…

Mesoscale and Nanoscale Physics · Physics 2021-12-10 Y. P. Pan , J. J. Zhu , Y. Feng , Y. S. Lin , H. B. Wang , X. Y. Liu , H. Jin , Z. Wang , L. Chen , Y. H. Wang

We investigate electric transport and noise properties of microstrip-type submicron direct current superconducting quantum interference devices (dc SQUIDs) based on Nb thin films and overdamped Josephson junctions with a HfTi barrier. The…

Scanning Superconducting QUantum Interference Device (SQUID) microscopy is a powerful tool for imaging local magnetic properties of materials and devices, but it requires a low-vibration cryogenic environment, traditionally achieved by…

Superconductivity · Physics 2019-07-04 Logan Bishop-Van Horn , Zheng Cui , John R. Kirtley , Kathryn A. Moler

Superconducting quantum interference devices (SQUIDs) are exceptionally sensitive magnetometers capable of detecting weak magnetic fields. Miniaturizing these devices and integrating them onto scanning probes enables high-resolution imaging…

Superconducting quantum interference devices (SQUIDs) are used for applications ranging from sensitive magnetometers to low-temperature electronics and quantum computation. We introduce a planar nano SQUID that was made with a single…

Applied Physics · Physics 2019-04-17 Itamar Holzman , Yachin Ivry

Superconducting Quantum Interference Devices (SQUIDs) can have excellent spin sensitivity depending on their magnetic flux noise, pick-up loop diameter, and distance from the sample. We report a family of scanning SQUID susceptometers with…

We study superconducting stripline resonator (SSR) made of Niobium, which is integrated with a superconducting interference device (SQUID). The large nonlinear inductance of the SQUID gives rise to strong Kerr nonlinearity in the response…

Superconductivity · Physics 2009-10-21 Oren Suchoi , Baleegh Abdo , Eran Segev , Oleg Shtempluck , M. P. Blencowe , Eyal Buks

We present a portable optically pumped magnetometer instrument for ultra-sensitive measurements within the Earth's magnetic field. The central part of the system is a sensor head operating a MEMS-based Cs vapor cell in the light-shift…

A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector. It comprises a resonator circuit constructed with a superconducting film on a dielectric substrate. To expand its field of application, it is…

Instrumentation and Detectors · Physics 2022-03-16 Yoshinori Sueno , Shunsuke Honda , Hiroki Kutsuma , Satoru Mima , Chiko Otani , Shugo Oguri , Junya Suzuki , Osamu Tajima

We describe a dispersive nanoSQUID magnetometer comprised of two variable thickness aluminum weak-link Josephson junctions shunted in parallel with an on-chip capacitor. This arrangement forms a nonlinear oscillator with a tunable 4-8 GHz…

Mesoscale and Nanoscale Physics · Physics 2013-04-16 E. M. Levenson-Falk , R. Vijay , N. Antler , I. Siddiqi

A scheme of an ultra-sensitive magnetometer in the cavity quantum electromagnonics where the intracavity microwave mode coupled to a magnonic mode via magnetic dipole interaction is proposed. It is shown that by driving both magnonic and…

Quantum Physics · Physics 2021-06-16 Mehri Sadat Ebrahimi , Ali Motazedifard , Malek Bagheri Harouni

We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz,…

We present the design, realization and performance of a three-axis vector nano Superconducting QUantum Interference Device (nanoSQUID). It consists of three mutually orthogonal SQUID nanoloops that allow distinguishing the three components…

Superconductivity · Physics 2016-06-24 M. J. Martínez-Pérez , D. Gella , B. Müller , V. Morosh , R. Wöbling , J. Sesé , O. Kieler , R. Kleiner , D. Koelle

Micron size superconducting quantum interference devices ($\mu$-SQUID) of lead (Pb), for probing nano-magnetism, were fabricated and characterized. In order to get continuous Pb films with small grain size, Pb was thermally evaporated on a…

Superconductivity · Physics 2021-12-06 Sagar Paul , Sourav Biswas , Anjan K. Gupta