English
Related papers

Related papers: A Large Ungated TPC with GEM Amplification

200 papers

In this paper we present the R&D activity on a new GEM-based TPC prototype for AMADEUS, a new experimental proposal at the DA{\Phi}NE {\Phi}-factory at the Laboratori Nazionali di Frascati (INFN), aiming to perform measurements of the…

Instrumentation and Detectors · Physics 2013-04-24 M. Poli Lener , M. Bazzi , G. Corradi , C. Curceanu , A. D'Uffizi , C. Paglia , E. Sbardella , A. Scordo , D. Tagnani , A. Romero Vidal , J. Zmeskal

The idea of a hermetic quartz chamber in a dual-phase xenon time projection chamber (TPC) has the potential to improve the detector sensitivity for direct dark matter searches in the future. A major challenge facing TPC detectors in future…

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…

Instrumentation and Detectors · Physics 2016-12-16 Moon Moon Devi , Naba K. Mondal , B. Satyanarayana , R. R. Shinde

We describe first results obtained with a track structure imaging system for measuring the ionisation topology of charged particles in a low-pressure gas. The detection method is based on a time projection chamber (TPC) filled with…

Instrumentation and Detectors · Physics 2007-05-23 U. Titt , V. Dangendorf , H. Schuhmacher

A simple but novel driver system has been developed to operate the wire gating grid of a Time Projection Chamber (TPC). This system connects the wires of the gating grid to its driver via low impedance transmission lines. When the gating…

GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification…

Instrumentation and Detectors · Physics 2020-07-15 Philip Hauer , Karl Flöthner , Dimitri Schaab , Jonathan Ottnad , Viktor Ratza , Markus Ball , Bernhard Ketzer

To extend the acceptance of the CMS muon spectrometer to the region 2.4 $<|\eta|<$ 2.8, stacks of triple-GEM chambers, forming the ME0 station, are planned for the CMS Phase 2 Upgrade. These large-area micro-pattern gaseous detectors must…

Sensitivities of current directional dark matter search detectors using gas time projection chambers are now constrained by target mass. A ton-scale gas TPC detector will require large charge readout areas. We present a first demonstration…

Instrumentation and Detectors · Physics 2020-11-24 A. C. Ezeribe , C. Eldridge , W. Lynch , R. R. Marcelo Gregorio , A. Scarff , N. J. C. Spooner

We report the design, construction, and initial commissioning results of a large high pressure gaseous Time Projection Chamber (TPC) with Micromegas modules for charge readout. The detector vessel has an inner volume of about 600 L and an…

The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD)…

Instrumentation and Detectors · Physics 2022-04-26 M. Dixit , D. Attie , A. Bellerive , K. Boudjemline , P. Colas , P. Giganon , I. Giomataris , V. Lepeltier , S. Liu , J. -P. Martin , K. Sachs , Y. Shin , S. Turnbull

Multi-gap Resistive Plate Chamber(MRPC) is a widely used timing detector with a typical time resolution of about 60 ps. This makes MRPC an optimal choice for the time of flight(ToF) system in many large physics experiments. The prior work…

Instrumentation and Detectors · Physics 2019-09-04 Fuyue Wang , Dong Han , Yi Wang , Yancheng Yu , Baohong Guo , Yuanjing Li

We report on the successful operation of a double phase Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC) equipped with two dimensional projective anodes with dimensions 10$\times$10 cm$^2$, and with a maximum…

Instrumentation and Detectors · Physics 2015-06-18 C. Cantini , L. Epprecht , A. Gendotti , S. Horikawa , S. Murphy , G. Natterer , L. Periale , F. Resnati , A. Rubbia , F. Sergiampietri , T. Viant , S. Wu

The HARP experiment was designed to study hadron production in proton- nucleus collisions in the energy range of 1.5 GeV/c-15 GeV/c. The experiment was made of two spectrometers, a forward dipole spectrometer and a large-angle solenoid…

A prototype of Multi-Wire Proportional Chambers (MWPC) has been fabricated for the study of its various characteristics. The detector contains gold-coated tungsten wires (20 $\mu m$ diameter) on the anode frame, with a pitch of 2.8 mm. The…

Instrumentation and Detectors · Physics 2021-10-06 Rajendra Nath Patra , R. N. Singaraju , S. Biswas , T. K. Nayak , Y. P. Viyogi

The ALICE Collaboration is planning a major upgrade of its central barrel detectors to be able to cope with the increased LHC luminosity beyond 2020. For the TPC, this implies a replacement of the currently used gated MWPCs (Multi-Wire…

Instrumentation and Detectors · Physics 2019-08-13 Andreas Mathis

The Time Projection Chamber is the main tracking and particle identification detector of the ALICE experiment. The high luminosities delivered by the CERN LHC in Run 2 (2015-2018) posed new challenges in terms of detector performance and…

Instrumentation and Detectors · Physics 2019-09-10 Ernst Hellbär

In the DeeMe experiment, approximately $70\ \mathrm{GHz/mm^{2}}$ prompt-charged particles will hit the multi-wire proportional chambers (MWPCs) before signal electrons come. To avoid the space charge effect, we developed fast HV-switching…

Instrumentation and Detectors · Physics 2018-12-05 N. Teshima

Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron…

Instrumentation and Detectors · Physics 2026-05-29 Sachin Rana , Md. Kaosor Ali Mondal , Poojan Angiras , Amal Sarkar

We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When…

Two cylindrical forward TPC detectors are described which were constructed to extend the phase space coverage of the STAR experiment to the region 2.5 < |\eta| < 4.0. For optimal use of the available space and in order to cope with the high…