Related papers: A 100-ps Multi-Time over Threshold Data Acquisitio…
The QuarkNet DAQ card for school-network cosmic ray detectors provides a low-cost alternative to using standard particle and nuclear physics fast pulse electronics modules. Individual detector stations, each consisting of 4 scintillation…
The Large High Altitude Air Shower Observatory (LHAASO) project has been proposed for the survey and study of cosmic rays. In the LHAASO project, the Water Cherenkov Detector Array (WCDA) is one of major detectors for searching gamma ray…
The Data Acquisition System of the LZ experiment, the 10-tonne dark matter detector to be installed at the Sanford Underground Research Facility (SURF), will collect signals from 788 photomultiplier tubes (PMTs). Because the signals from…
In this paper, we design a PXI-based, multi-channel data-acquisition system (DAS) mainly applicable to recording one-shot fast transient pulses in nuclear physics experiments. The system consists of one NI PXIe-1085 chassis, containing a…
Time over dynamic threshold (TODT) method, proposed in our previous work, has been successfully used for nuclear pulse charge measurement in PET detectors. It has advantages of strict linearity, large dynamic range, and better energy…
The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The…
A neutron monitor (NM) is, since the 1950s, a standard ground-based detector whose count rate reflects cosmic-ray variability. The worldwide network of NMs forms a rough spectrometer for cosmic rays. Recently, a brand-new data acquisition…
We measured signals of low amplitudes originating from cosmic rays, using two rectangular-block scintillation detectors at various positions. The signals were analyzed by a slightly modified signal analyzer from project 'MuonLab', designed…
Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…
In order to improve the particle identification capability of the Beijing Spectrometer III (BESIII),t is proposed to upgrade the current endcap time-of-flight (ETOF) detector with multi-gap resistive plate chamber (MRPC) technology. Aiming…
In this paper, we describe a modular data acquisition system developed as the foundation of a cosmic ray detector network. Each detector setup (henceforth referred as a station) is composed of an independent hardware device that can be…
New front-end electronics including ASICs and FPGA boards are under development for the ATLAS Monitored Drift Tube (MDT) detector to handle the large data rates and harsh environment expected at high-luminosity LHC runs. A mobile Data…
The FemtoDAQ is a low-cost two channel data acquisition system which we have used to investigate the signal characteristics of silicon photomultipliers (SiPMs) coupled to fast scintillators. The FemtoDAQ system can also be used to…
In the last years, high-resolution time tagging has emerged as the tool to tackle the problem of high-track density in the detectors of the next generation of experiments at particle colliders. Time resolutions below 50ps and event average…
The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis…
A real-time Data Acquisition (DAQ) system for the CULTASK axion haloscope experiment was constructed and tested. The CULTASK is an experiment to search for cosmic axions using resonant cavities, to detect photons from axion conversion…
Microwave reflectometry is a non-intrusive plasma diagnostic tool which is widely applied in many fusion devices. In 2014, the microwave reflectometry on Experimental Advanced Superconducting Tokamak (EAST) had been upgraded to measure…
The time-of-flight (TOF) system in the Compressed Baryonic Matter (CBM) experiment is composed of super modules based on multi-gap Resistive Plate Chambers (MRPC) for high-denseness, high-resolution time measurement. In order to evaluate…
We present a data acquisition~(DAQ) software based on the MIDAS framework, specifically for gaseous detectors to support the detector deployments and applications. It implements a comprehensive suite of functions, including parameter…
The Multi-voltage Threshold (MVT) method, which samples the signal by certain reference voltages, has been well developed as being adopted in pre-clinical and clinical digital positron emission tomography(PET) system. To improve its energy…