English
Related papers

Related papers: Removing krypton from xenon by cryogenic distillat…

200 papers

A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based…

Instrumentation and Detectors · Physics 2022-06-15 E. Aprile , K. Abe , F. Agostini , S. Ahmed Maouloud , M. Alfonsi , L. Althueser , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , L. Baudis , A. L. Baxter , L. Bellagamba , A. Bernard , R. Biondi , A. Bismark , A. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , B. Cimmino , M. Clark , A. P. Colijn , J. Conrad , J. J. Cuenca-García , J. P. Cussonneau , V. D'Andrea , M. P. Decowski , P. Di Gangi , S. Di Pede , A. Di Giovanni , R. Di Stefano , S. Diglio , A. Elykov , S. Farrell , A. D. Ferella , H. Fischer , S. Form , W. Fulgione , P. Gaemers , R. Gaior , M. Galloway , F. Gao , R. Glade-Beucke , L. Grandi , J. Grigat , A. Higuera , C. Hils , K. Hiraide , L. Hoetzsch , J. Howlett , C. Huhmann , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , N. Kato , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , M. Messina , K. Miuchi , K. Mizukoshi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , K. Ni , U. Oberlack , J. Palacio , R. Peres , J. Pienaar , M. Pierre , V. Pizzella , G. Plante , J. Qi , J. Qin , D. Ramírez García , S. Reichard , A. Rocchetti , N. Rupp , L. Sanchez , J. M. F. dos Santos , G. Sartorelli , J. Schreiner , D. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , E. Shockley , M. Silva , H. Simgen , A. Takeda , P. -L. Tan , A. Terliuk , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , Y. Wei , C. Weinheimer , M. Weiss , D. Wenz , J. Westermann , C. Wittweg , T. Wolf , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , Y. Zhang , M. Zhong , T. Zhu , J. P. Zopounidis

An efficient cryogenic distillation system was designed and constructed for PandaX-4T dark matter detector based on the McCabe-Thiele (M-T) method and the conservation of mass and energy. This distillation system is designed to reduce the…

A high performance distillation system to remove krypton from xenon was constructed, and a purity level of Kr/Xe = $\sim 3 \times 10^{-12}$ was achieved. This development is crucial in facilitating high sensitivity low background…

We have developed a new method to measure krypton traces in xenon at unprecedented low concentrations. This is a mandatory task for many near-future low-background particle physics detectors. Our system separates krypton from xenon using…

Instrumentation and Detectors · Physics 2014-03-28 Sebastian Lindemann , Hardy Simgen

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is…

Instrumentation and Detectors · Physics 2021-08-11 Xiangyi Cui , Zhou Wang , Yonglin Ju , Xiuli Wang , Huaxuan Liu , Wenbo Ma , Jianglai Liu , Li Zhao , Xiangdong Ji , Shuaijie Li , Rui Yan , Haidong Sha , Peiyao Huang

A high-flow radon removal system based on cryogenic distillation was developed and constructed to reduce radon-induced backgrounds in liquid xenon detectors for rare event searches such as XENONnT. A continuous purification of the XENONnT…

Instrumentation and Detectors · Physics 2022-12-28 M. Murra , D. Schulte , C. Huhmann , C. Weinheimer

We extend our technique for observing very small concentrations of impurities in xenon gas to the problem of krypton detection. We use a conventional mass spectrometer to identify the krypton content of the xenon, but we improve the…

Instrumentation and Methods for Astrophysics · Physics 2015-03-19 A. Dobi , C. G. Davis , C. Hall , T. Langford , S. Slutsky , Y. R. Yen

Krypton-85 is an anthropogenic beta-decaying isotope which produces low energy backgrounds in dark matter and neutrino experiments, especially those based upon liquid xenon. Several technologies have been developed to reduce the Kr…

Instrumentation and Detectors · Physics 2017-04-26 D. Yu. Akimov , A. I. Bolozdynya , A. A. Burenkov , C. Hall , A. G. Kovalenko , V. V. Kuzminov , G. E. Simakov

The XENONnT experiment has achieved an exceptionally low $^\text{222}$Rn activity concentration within its inner 5.9$\,$tonne liquid xenon detector of (0.90$\,\pm\,$0.01$\,$stat.$\,\pm\,$0.07 sys.)$\,\mu$Bq/kg, equivalent to about 430…

Instrumentation and Detectors · Physics 2025-04-28 E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , D. Antón Martin , F. Arneodo , L. Baudis , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , K. Boese , A. Brown , G. Bruno , R. Budnik , C. Cai , C. Capelli , J. M. R. Cardoso , A. P. Cimental Chávez , A. P. Colijn , J. Conrad , J. J. Cuenca-García , V. D'Andrea , L. C. Daniel Garcia , M. P. Decowski , A. Deisting , C. Di Donato , P. Di Gangi , S. Diglio , K. Eitel , S. el Morabit , A. Elykov , A. D. Ferella , C. Ferrari , H. Fischer , T. Flehmke , M. Flierman , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , M. Galloway , F. Gao , S. Ghosh , R. Giacomobono , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guida , P. Gyorgy , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , Y. Kaminaga , M. Kara , P. Kavrigin , S. Kazama , P. Kharbanda , M. Kobayashi , D. Koke , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , Z. Liang , Y. -T. Lin , S. Lindemann , M. Lindner , K. Liu , M. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , T. Luce , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , E. Masson , S. Mastroianni , A. Melchiorre , J. Merz , M. Messina , A. Michael , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , U. Oberlack , B. Paetsch , Y. Pan , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , L. Principe , J. Qi , J. Qin , D. Ramírez García , M. Rajado , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , D. Schulte , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , J. Shi , M. Silva , H. Simgen , C. Szyszka , A. Takeda , Y. Takeuchi , P. -L. Tan , D. Thers , F. Toschi , G. Trinchero , C. D. Tunnell , F. Tönnies , K. Valerius , S. Vecchi , S. Vetter , F. I. Villazon Solar , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong

The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in…

Instrumentation and Detectors · Physics 2025-08-14 XENON Collaboration , E. Aprile , J. Aalbers , K. Abe , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , J. R. Angevaare , V. C. Antochi , D. Antón Martin , F. Arneodo , M. Balata , L. Baudis , A. L. Baxter , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , E. J. Brookes , A. Brown , S. Bruenner , G. Bruno , R. Budnik , T. K. Bui , C. Cai , J. M. R. Cardoso , F. Cassese , A. Chiarini , D. Cichon , A. P. Cimental Chavez , A. P. Colijn , J. Conrad , R. Corrieri , J. J. Cuenca-García , J. P. Cussonneau , O. Dadoun , V. D'Andrea , M. P. Decowski , B. De Fazio , P. Di Gangi , S. Diglio , J. M. Disdier , D. Douillet , K. Eitel , A. Elykov , S. Farrell , A. D. Ferella , C. Ferrari , H. Fischer , M. Flierman , S. Form , D. Front , W. Fulgione , C. Fuselli , P. Gaemers , R. Gaior , A. Gallo Rosso , M. Galloway , F. Gao , R. Gardner , N. Garroum , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guerzoni , M. Guida , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , J. Howlett , C. Huhmann , M. Iacovacci , G. Iaquaniello , L. Iven , Y. Itow , J. Jakob , F. Joerg , A. Joy , M. Kara , P. Kavrigin , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , F. Kuger , H. Landsman , R. F. Lang , L. Levinson , I. Li , S. Li , S. Liang , S. Lindemann , M. Lindner , K. Liu , J. Loizeau , F. Lombardi , J. Long , J. A. M. Lopes , Y. Ma , C. Macolino , J. Mahlstedt , A. Mancuso , L. Manenti , F. Marignetti , T. Marrodán Undagoitia , P. Martella , K. Martens , J. Masbou , D. Masson , E. Masson , S. Mastroianni , E. Mele , M. Messina , R. Michinelli , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , Y. Mosbacher , M. Murra , J. Müller , K. Ni , S. Nisi , U. Oberlack , D. Orlandi , R. Othegraven , B. Paetsch , J. Palacio , S. Parlati , P. Paschos , Q. Pellegrini , R. Peres , C. Peters , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , J. Qi , J. Qin , D. Ramírez García , M. Rynge , J. Shi , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , D. Schulte , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , S. Shi , E. Shockley , M. Silva , H. Simgen , J. Stephen , M. Stern , B. K. Stillwell , A. Takeda , P. -L. Tan , D. Tatananni , A. Terliuk , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , F. Tönnies , K. Valerius , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , J. Westermann , C. Wittweg , T. Wolf , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , L. Yang , J. Ye , L. Yuan , G. Zavattini , M. Zhong , T. Zhu

XENON is a novel liquid xenon experiment concept for a sensitive dark matter search using a 1-tonne active target, distributed in an array of ten independent time projection chambers. The design relies on the simultaneous detection of…

We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K…

Instrumentation and Detectors · Physics 2015-06-11 Elena Aprile , Ran Budnik , Bin Choi , Hugo Contreras , Karl Giboni , Luke Goetzke , Rafael Lang , Kyungeun Lim , Antonio melgarejo , Petr Shagin

Tritium from tritiated methane (CH$_3$T) calibration is a significant impurity that restricts the sensitivity of the PandaX-4T dark matter detection experiment in the low-energy region. The CH$_3$T removal is essential for PandaX-4T and…

Instrumentation and Detectors · Physics 2025-10-29 Shuaijie Li , Zhou Wang , Xiangyi Cui , Li Zhao , Yonglin Ju , Wenbo Ma , Yingjie Fan , Jianglai Liu , Liqiang Liu , Kai Kang

The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically…

The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xenon nuclei. With a fiducial mass of 1000 kg of liquid xenon, a sufficiently low…

Astrophysics · Physics 2007-05-23 XENON Collaboration , Elena Aprile

The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and…

Instrumentation and Detectors · Physics 2019-07-03 E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , L. Althueser , F. D. Amaro , V. C. Antochi , F. Arneodo , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , A. Elykov , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , L. Grandi , Z. Greene , C. Hasterok , E. Hogenbirk , J. Howlett , M. Iacovacci , R. Itay , F. Joerg , S. Kazama , A. Kish , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , E. López Fune , C. Macolino , J. Mahlstedt , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , J. Masbou , D. Masson , S. Mastroianni , M. Messina , K. Micheneau , K. Miller , A. Molinario , K. Morå , Y. Mosbacher , M. Murra , J. Naganoma , K. Ni , U. Oberlack , K. Odgers , B. Pelssers , F. Piastra , J. Pienaar , V. Pizzella , G. Plante , R. Podviianiuk , H. Qiu , D. Ramírez García , S. Reichard , B. Riedel , A. Rizzo , A. Rocchetti , N. Rupp , J. M. F. dos Santos , G. Sartorelli , N. Šarčević , M. Scheibelhut , S. Schindler , J. Schreiner , D. Schulte , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , N. Upole , M. Vargas , O. Wack , H. Wang , Z. Wang , Y. Wei , C. Weinheimer , D. Wenz , C. Wittweg , J. Wulf , J. Ye , Y. Zhang , T. Zhu , J. P. Zopounidis

We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon…

Instrumentation and Detectors · Physics 2017-06-05 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , E. Duchovni , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , D. Franco , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , L. Grandi , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , M. Le Calloch , Q. Lin , S. Lindemann , M. Lindner , J. A. M. Lopes A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , Y. Meng , M. Messina , K. Micheneau , B. Miguez , A. Molinario , M. Murra , J. Naganoma , K. Ni , U. Oberlack , S. E. A. Orrigo , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , S. Rosendahl , N. Rupp , R. Saldanha , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , N. Upole , H. Wang , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang , I. Cristescu

We have developed an atom trap trace analysis (ATTA) system to measure Kr in Xe at the part per trillion (ppt) level, a prerequisite for the sensitivity achievable with liquid xenon dark matter detectors beyond the current generation. Since…

Atomic Physics · Physics 2013-09-30 Elena Aprile , Taehyun Yoon , Andre Loose , Luke W. Goetzke , Tanya Zelevinsky

A new method for measuring trace amounts of krypton in xenon using a cold trap with a residual gas analyzer has been developed, which achieves an increased sensitivity by temporarily reducing the pumping speed while expending a minimal…

Instrumentation and Detectors · Physics 2015-06-12 Ethan Brown , Stephan Rosendahl , Christian Huhmann , Christian Weinheimer , Hans Kettling

XENON is a project for direct dark matter search located in the INFN underground laboratory LNGS. The previous generation of XENON detector, XENON1T, achieved an exposure of 1 ton$\times$year, setting the most stringent limits on the…

High Energy Physics - Experiment · Physics 2023-10-18 S. E. M. Ahmed Maouloud
‹ Prev 1 2 3 10 Next ›