Related papers: Pile-up corrections in laser-driven pulsed x-ray s…
Pulse pile-up in pulse-height energy analyzers increases when the incident rate of pulses increases relative to the inverse of the dead time per pulse of the detection system. Changes in the observed energy distributions with incident rate…
Compared with the start-of-art energy integration detectors (EIDs), photon-counting detectors (PCDs) with energy discrimination capabilities have demonstrated great potentials in various applications of medical x-ray radiography and…
We have developed a simulation-based method of spectral analysis for pile-up affected data of X-ray CCDs without any loss of photon statistics. As effects of the photon pile-up appear as complicated nonlinear detector responses, we employ a…
We report a pile-up rejection technique based on X-ray absorption concept of Beer-Lambert law for measuring true events in the pile-up region. We have detected a 10^4 times weaker peak in the pile-up region. This technique also enables one…
Microdosimetry investigates the energy deposition of ionizing radiation at microscopic scales, beyond the assessment capabilities of macroscopic dosimetry. This contributes to an understanding of the biological response in radiobiology,…
The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important…
The spectrum of laser-plasma generated X-rays is very important, it characterizes electron dynamics in plasma and is basic for applications. However, the accuracies and efficiencies of existing methods to diagnose the spectrum of…
Pulse-pileup affects most photon counting systems and occurs when photon detections occur faster than the detector's registration and recovery time. At high input rates, shaped pulses interfere and the source spectrum, as well as intensity…
The effective bandwidth of an energy dispersive x-ray fluorescence spectroscopy system is limited by the timing of incident photons. When multiple photons strike the detector within the processing time of the detector photon pile-up occurs…
Modern photon counting pixel detectors enabled a revolution in applications at synchrotron light sources and beyond in the last decade. One of the limitations of current detectors is reduced counting linearity or even paralysis at high…
Short pulse lasers are used to characterize the nonlinear response of amplified photodetectors. Two widely used balanced detectors are characterized in terms of amplitude, area, broadening, and balancing the mismatch of their impulse…
Pile-up signals are frequently produced in experimental physics. They create inaccurate physics data with high uncertainty and cause various problems. Therefore, the correction to pile-up signals is crucially required. In this study, we…
X-ray charge-coupled devices (CCDs) are the workhorse detectors of modern X-ray astronomy. Typically covering the 0.3-10.0 keV energy range, CCDs are able to detect photoelectric absorption edges and K shell lines from most abundant metals.…
Single-photon avalanche diode (SPAD) based transient imaging suffers from an aberration called pile-up. When multiple photons arrive within a single repetition period of the illuminating laser, the SPAD records only the arrival of the first…
A novel type of pulsed X-ray generator especially suitable for rare event searches, as dark matter and neutrino experiments, has been developed. Being compact and built with selected radio-pure materials, it is appropriate for…
Scattering of ultraintense short laser pulses off relativistic electrons allows one to generate a large number of X- or $\gamma$-ray photons with the expense of the spectral width---temporal pulsing of the laser inevitable leads to…
We present the result of a systematic study of pileup phenomena seen in the X-ray Imaging Spectrometer, an X-ray CCD instrument, onboard the Suzaku observatory. Using a data set of observed sources in a wide range of brightness and spectral…
Gain calibration of x-ray area detectors is a challenge due to the inability to generate an x-ray flat field at the selected photon energy that the beamline operates at, which has a strong influence on the detector's gain behavior. A method…
Using Time-Correlated Single Photon Counting (TCSPC) for the purpose of fluorescence lifetime measurements is usually limited in speed due to pile-up. With modern instrumentation this limitation can be lifted significantly but some…
Silicon drift detectors (SDDs) revolutionized spectroscopy in fields as diverse as geology and dentistry. For a subset of experiments at ultra-fast, x-ray free-electron lasers (FELs), SDDs can make substantial contributions. Often the…