English
Related papers

Related papers: A Scanning Hall Probe Microscope for high resoluti…

200 papers

We have built a variable temperature scanning probe microscope (SPM) that covers 4.6 K - 180 K and up to 7 Tesla whose SPM head fits in a 52 mm bore magnet. It features a temperature-controlled sample stage thermally well isolated from the…

Instrumentation and Detectors · Physics 2017-11-22 Jin-Oh Jung , Seokhwan Choi , Yeonghoon Lee , Jinwoo Kim , Donghyun Son , Jhinhwan Lee

Scanning Probe Microscopy allows for extreme resolution down to the atomic scale. Unfortunately, total scanning range is rather limited, therefore finding a specific position on the sample is tedious. This is an important limitation of many…

Materials Science · Physics 2015-06-12 José Abad , Juan Francisco González Martínez , Jaime Colchero Paetz

We present a novel technique for the investigation of local variations of the critical current density in large bulk superconductors. In contrast to the usual Hall probe scanning technique, the sample is not magnetized as a whole before the…

Superconductivity · Physics 2016-08-31 M. Eisterer , S. Haindl , T. Wojcik , H. W. Weber

The Scanning Tunneling Microscope (STM) is a powerful instrument to study electronic density of states at surfaces down to atomic scale. Many interesting samples require studying variations as a function of the magnetic field, which is most…

We demonstrate a scanning force microscope, based upon a quartz tuning fork, that operates below 100 mK and in magnetic fields up to 6 T. The microscope has a conducting tip for electrical probing of nanostructures of interest, and it…

Mesoscale and Nanoscale Physics · Physics 2007-05-23 K. R. Brown , L. Sun , B. E. Kane

Fabrication, characterization and comparison of gold and graphene micro- and nano-size Hall sensors for room temperature scanning magnetic field microscopy applications is presented. The Hall sensors with active areas from 5 $\mu$m down to…

The Hall response function of symmetric and asymmetric planar Hall effect devices is investigated by scanning a magnetized tip above a sensor surface while simultaneously recording the topography and the Hall voltage. Hall sensor geometries…

Mesoscale and Nanoscale Physics · Physics 2009-11-07 H. Guillou , A. D. Kent , G. W. Stupian , M. S. Leung

A scanning force microscope was implemented operating at temperatures below 4.2K and in magnetic fields up to 8T. Piezoelectric quartz tuning forks were employed for non optical tip-sample distance control in the dynamic operation mode.…

Condensed Matter · Physics 2009-10-31 J. Rychen , T. Ihn , P. Studerus , A. Herrmann , K. Ensslin

Micro scanning mirrors (MSM) extend the range and field of view of LiDARs, medical imaging devices, and laser projectors. However, a new class of soft-hinged MSMs contains out-of-plane translation in addition to the 2 degree-of-freedom…

Robotics · Computer Science 2023-11-27 Di Wang , Xiaoyu Duan , Shu-Hao Yeh , Jun Zou , Dezhen Song

A novel scanning probe technique is presented: Scanning microSQUID Force microscopy (SSFM). The instrument features independent topographic and magnetic imaging. The SSFM operates in a dilution refrigerator in cryogenic vacuum. Sample and…

Superconductivity · Physics 2007-05-23 C. Veauvy , D. Mailly , K. Hasselbach

We have developed a low temperature, high resolution magnetic force microscope (MFM) using a quartz tuning fork that can operate in a magnetic field. A tuning fork with a spring constant of 1300 N/m mounted with a commercial MFM cantilever…

Mesoscale and Nanoscale Physics · Physics 2009-11-11 Yongho Seo , Paul Cadden-Zimansky , Venkat Chandrasekhar

We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100…

Mesoscale and Nanoscale Physics · Physics 2014-04-03 S. E. de Graaf , A. V. Danilov , A. Adamyan , S. E. Kubatkin

A Hall magnetometer with variable sensitivity is constructed to measure the magnetic properties of magnetic nanoparticles manufactured by different methods. This novel magnetometer can also be used to measure bulk materials and samples in…

Scanning probe microscopy is one of the most versatile windows into the nanoworld, providing imaging access to a variety of sample properties, depending on the probe employed. Tunneling probes map electronic properties of samples, magnetic…

Mesoscale and Nanoscale Physics · Physics 2015-01-09 Thomas Häberle , Dominik Schmid-Lorch , Friedemann Reinhard , Jörg Wrachtrup

We have developed a near-field scanned microwave probe with a sampling volume of approximately 10 micron in diameter, which is the smallest one achieved in near-field microwave microscopy. This volume is defined to confine close to 100…

Materials Science · Physics 2009-08-03 Vladimir V. Talanov , Andre Scherz , Robert L. Moreland , Andrew R. Schwartz

We present a comprehensive method for visualisation and quantification of the magnetic stray field of magnetic force microscopy (MFM) probes, applied to the particular case of custom-made multi-layered probes with controllable high/low…

We describe the design and performance of a scanning tunneling microscope (STM) which operates at a base temperature of 30 mK in a vector magnetic field. The cryogenics is based on an ultra-high vacuum (UHV) top-loading wet dilution…

We present a design for a tunneling-current-assisted scanning near-field microwave microscope. For stable operation at cryogenic temperatures, making a small and rigid microwave probe is important. Our coaxial resonator probe has a length…

Mesoscale and Nanoscale Physics · Physics 2016-06-13 Hideyuki Takahashi , yoshinori imai , Atsutaka Maeda

We report on state-of-the-art scanning probe microscopy measurements performed in a pulse tube based top-loading closed-cycle cryostat with a base temperature of 4 K and a 9 T magnet. We decoupled the sample space from the mechanical and…

We present the design and calibration measurements of a scanning tunneling microscope setup in a 3He ultrahigh-vacuum cryostat operating at 400 mK with a hold time of 10 days. With 2.70 m in height and 4.70 m free space needed for assembly,…

‹ Prev 1 2 3 10 Next ›