The quantum oscillations of the dc voltage are induced on segments of asymmetric superconducting loops by an external ac current or noise. The dependencies of the amplitude of the quantum oscillations on amplitude of inducing ac current are…
We present here the concept of three-arm current comparator impedance bridge, which allows comparisons among three unlike impedances. Its purpose is the calibration of impedances having arbitrary phase angles, against calibrated nearly-pure…
In this paper, we address the calibration of the quantum efficiency of single-photon cameras using radioluminescent light sources. The proposed methods are subsequently compared with absolute calibration techniques based on the detection of…
We present a hybrid system consisting of a superconducting coplanar waveguide resonator coupled to a nanomechanical string and a transmon qubit acting as nonlinear circuit element. We perform spectroscopy for both the transmon qubit and the…
In four-dimensional scanning transmission electron microscopy (4D STEM) a focused beam is scanned over a specimen and a diffraction pattern is recorded at each position using a pixelated detector. During the experiment, it must be ensured…
This paper studies sensor calibration in spectral estimation where the true frequencies are located on a continuous domain. We consider a uniform array of sensors that collects measurements whose spectrum is composed of a finite number of…
The calibration of high-quality two-qubit entangling gates is an essential component in engineering large-scale, fault-tolerant quantum computers. However, many standard calibration techniques are based on randomized circuits that are only…
Aligning a microcantilever to an area of interest on a sample is a critical step in many scanning probe microscopy experiments, particularly those carried out on devices and rare, precious samples. We report a series of protocols that…
In-circuit impedance provides key information for many EMC applications. The inductive coupling approach is a promising method for in-circuit impedance measurement because its measurement setups have no direct electrical contact with the…
This article presents an interactive system for stage acoustics experimentation including considerations for hearing one's own and others' instruments. The quality of real-time auralization systems for psychophysical experiments on music…
Ultra-Wideband (UWB) systems are becoming increasingly popular for indoor localization, where range measurements are obtained by measuring the time-of-flight of radio signals. However, the range measurements typically suffer from a…
One of the biggest challenges in operating massive multiple-input multiple-output systems is the acquisition of accurate channel state information at the transmitter. To take up this challenge, time division duplex is more favorable thanks…
Various applications of quantum devices call for an accurate calibration of cryogenic amplification chains. To this end, we present a convenient calibration scheme and use it to accurately measure the total gain and noise temperature of an…
In this work, a new method for designing an analog circuit for deep sub-micron CMOS fabrication processes is proposed. The proposed method leverages the regression algorithms with the transistor circuit model to size a transistor in 0.18 um…
For the submillimeter band observations, we have been routinely adopting the calibration cycle time of 20-30 minutes, which is the same as any typical centimeter and millimeter band observations. This cycle time, largely corrects only the…
The main task of an energy calibration is to find a relation between pulse-height values and the corresponding energies. Doing this for each pulse-height channel individually requires an elaborated input spectrum with an excellent counting…
This paper presents an analysis and rigorous procedure for determining the optimal lengths of line standards in multiline thru-reflect-line (TRL) calibration of vector network analyzers (VNAs). The solution is obtained through nonlinear…
This paper proposes an accurate and efficient Universal Adaptive Stabilizer (UAS) based online parameters estimation technique for a 400 V Li-ion battery bank. The battery open circuit voltage, parameters modeling the transient response,…
The process of calibrating instrument transformers (ITs) has been greatly simplified by using phasor measurement unit (PMU) data since this process eliminates the need for (a) additional hardware, and (b) taking ITs offline. However, such…
Resistive switching devices, important for emerging memory and neuromorphic applications, face significant challenges related to control of delicate filamentary states in the oxide material. As a device switches, its rapid conductivity…