English
Related papers

Related papers: Calibration setup for ultralow-current transresist…

200 papers

In this paper, a four-point characterization method is developed for resistive samples connected to either resistive or capacitive contacts. Provided the circuit equivalent of the complete measurement system is known including coaxial cable…

Other Condensed Matter · Physics 2015-05-30 Brian S. Kim , Wang Zhou , Yash D. Shah , Chuanle Zhou , N. Işık , M. Grayson

This paper discusses a linear programming approach for designing switching signals for controlled rectifiers to achieve a low input current & output voltage total harmonic distortions. The focus here is on fully controlled rectifiers made…

Systems and Control · Electrical Eng. & Systems 2020-02-26 Shravan Mohan

In the past few years, advancements in the field of nano circuit design has become tougher than the demand. Low power devices have emerged tremendously.Both voltage mode aswell as current mode devices have proven alternative to each other…

Signal Processing · Electrical Eng. & Systems 2018-11-07 Umar Mohammad , Mir Aamir Shafi

Pipelined analog-to-digital converters (ADCs) are fundamental components of various signal processing systems requiring high sampling rates and a high linearity. Over the past years, calibration techniques have been intensively investigated…

Signal Processing · Electrical Eng. & Systems 2022-07-12 Matthias Wagner , Oliver Lang , Thomas Bauernfeind , Mario Huemer

Electron counting experiments attempt to provide a current of a known number of electrons per unit time. We propose architectures utilizing a few readily available electron-pumps or turnstiles with modest error rates of 1 part per $10^4$…

Mesoscale and Nanoscale Physics · Physics 2013-05-30 Michael Wulf

An important device for modulation and frequency translation in the field of circuit quantum electrodynamics is the IQ mixer, an analog component for which calibration is necessary to achieve optimal performance. In this paper, we introduce…

Quantum Physics · Physics 2021-01-01 S. W. Jolin , R. Borgani , M. O. Tholén , D. Forchheimer , D. B. Haviland

A novel inverse relaxation technique for supercapacitor characterization is developed, modeled numerically, and experimentally tested on a number of commercial supercapacitors. It consists in shorting a supercapacitor for a short time…

Applied Physics · Physics 2020-12-07 Mikhail Evgenievich Kompan , Vladislav Gennadievich Malyshkin

Quantum computation requires the precise control of the evolution of a quantum system, typically through application of discrete quantum logic gates on a set of qubits. Here, we use the cross-resonance interaction to implement a gate…

MALTA2 is a depleted monolithic active pixel sensor (DMAPS) designed for tracking at high rates and typically low detection threshold of $\sim150\,\mathrm{e^-}$. A precise knowledge of the threshold is crucial to understanding the charge…

We report on a calibration procedure that enhances the precision of an interferometer based frequency stabilization by several orders of magnitude. For this purpose the frequency deviations of the stabilization are measured precisely by…

Optics · Physics 2012-08-14 Johannes F. S. Brachmann , Thomas Kinder , Kai Dieckmann

A high-accuracy calibration of inductive coil sensors based on Printed Circuit Board (PCB), commonly used in rotating coil field measurements of particle accelerator magnets, is presented. The amplitude and phase of signals with and without…

Accelerator Physics · Physics 2019-03-04 Joseph DiMarco , Giordana Severino , Pasquale Arpaia

An important step in building a quantum computer is calibrating experimentally implemented quantum gates to produce operations that are close to ideal unitaries. The calibration step involves estimating the systematic errors in gates and…

Quantum Physics · Physics 2021-10-22 Shelby Kimmel , Guang Hao Low , Theodore J. Yoder

Optical tweezers find applications in various fields, ranging from biology to physics. One of the fundamental steps necessary to perform quantitative measurements using trapped particles is the calibration of the tweezer's spring constant.…

Quantum Physics · Physics 2020-06-05 Bruno Melo , Felipe Almeida , Guilherme Temporão , Thiago Guerreiro

This paper addresses the problem of choosing a sparse subset of measurements for quick calibration parameter estimation. A standard solution to this is selecting a measurement only if its utility -- the difference between posterior (with…

Robotics · Computer Science 2024-09-12 Jongwon Lee , David Hanley , Timothy Bretl

Contactless characterization of mechanical resonances using Fabry-Perot interferometry is a powerful tool to study the mechanical and dynamical properties of atomically thin membranes. However, amplitude calibration is often not performed,…

Mesoscale and Nanoscale Physics · Physics 2018-01-17 Robin J. Dolleman , Dejan Davidovikj , Herre S. J. van der Zant , Peter G. Steeneken

We present details on the current measurement setup at PTB used for high precision loss calibrations in the frequency range 50 Hz to 1 kHz. A combination of analog and digital feedback control is utilized in accordance with the standard. A…

Instrumentation and Detectors · Physics 2023-11-03 K. Pfnuer , J. Luedke , K. Hoffmann , F. Weickert

Capacitance measurements are crucial for probing the electrical properties of materials. In this study, we develop and implement a capacitance measurement technique optimized for pulsed magnetic fields. Our approach employs an…

High impedance connecting links and cables are modeled at low frequency in terms of their impedance to ground and to neigbouring connecting links. The impedance is usually considered to be the parallel combination of a resistance and a…

Instrumentation and Detectors · Physics 2013-07-18 Andrea Giachero , Claudio Gotti , Matteo Maino , Gianluigi Pessina

While in a triggered experiment the matching of the RPC transmission line impedance with the one of the front-end electronics is less critical, for a trigger-less data recording this becomes mandatory. As expected, impedance matching is not…

Instrumentation and Detectors · Physics 2017-08-10 D. Bartoş , M. Petriş , M. Petrovici , L. Rădulescu , V. Simion

This paper proposes an efficient method for the calculation of the stabilization parameters in RF power amplifiers operating in periodic large-signal regimes. Stabilization is achieved by applying the principles of linear control theory for…

Systems and Control · Electrical Eng. & Systems 2025-01-30 Libe Mori , Ibone Lizarraga , Aitziber Anakabe , Juan-Mari Collantes , Vincent Armengaud , Geoffroy Soubercaze-Pun