English
Related papers

Related papers: Low-Dose CT via Deep Neural Network

200 papers

Noise in low-dose computed tomography (LDCT) can obscure important diagnostic details. While deep learning offers powerful denoising, supervised methods require impractical paired data, and self-supervised alternatives often use opaque,…

Image and Video Processing · Electrical Eng. & Systems 2026-02-19 Yipeng Sun , Linda-Sophie Schneider , Siyuan Mei , Jinhua Wang , Ge Hu , Mingxuan Gu , Chengze Ye , Fabian Wagner , Lan Song , Siming Bayer , Andreas Maier

Low-dose computed tomography (LDCT) is an important topic in the field of radiology over the past decades. LDCT reduces ionizing radiation-induced patient health risks but it also results in a low signal-to-noise ratio (SNR) and a potential…

Image and Video Processing · Electrical Eng. & Systems 2022-10-03 Wenjun Xia , Qing Lyu , Ge Wang

The remarkable success of deep learning methods in solving computer vision problems, such as image classification, object detection, scene understanding, image segmentation, etc., has paved the way for their application in biomedical…

Image and Video Processing · Electrical Eng. & Systems 2024-12-05 Prabhat Kc , Rongping Zeng

Low-dose computed tomography (CT) denoising algorithms aim to enable reduced patient dose in routine CT acquisitions while maintaining high image quality. Recently, deep learning~(DL)-based methods were introduced, outperforming…

Image and Video Processing · Electrical Eng. & Systems 2022-10-21 Fabian Wagner , Mareike Thies , Felix Denzinger , Mingxuan Gu , Mayank Patwari , Stefan Ploner , Noah Maul , Laura Pfaff , Yixing Huang , Andreas Maier

Low-dose computed tomography (LDCT) reduces patient radiation exposure but introduces substantial noise that degrades image quality and hinders diagnostic accuracy. Existing denoising approaches often require many diffusion steps, limiting…

Medical Physics · Physics 2025-10-29 Qiang Li , Mojtaba Safari , Shansong Wang , Huiqiao Xie , Jie Ding , Tonghe Wang , Xiaofeng Yang

Low-dose computed tomography (CT) images suffer from noise and artifacts due to photon starvation and electronic noise. Recently, some works have attempted to use diffusion models to address the over-smoothness and training instability…

Image and Video Processing · Electrical Eng. & Systems 2024-01-10 Qi Gao , Zilong Li , Junping Zhang , Yi Zhang , Hongming Shan

Computed Tomography (CT) is a vital diagnostic tool in clinical practice, yet the health risks associated with ionizing radiation cannot be overlooked. Low-dose CT (LDCT) helps mitigate radiation exposure but simultaneously leads to reduced…

Computer Vision and Pattern Recognition · Computer Science 2025-11-20 Guoliang Gong , Man Yu

In this paper, we propose a state-of-the-art video denoising algorithm based on a convolutional neural network architecture. Until recently, video denoising with neural networks had been a largely under explored domain, and existing methods…

Computer Vision and Pattern Recognition · Computer Science 2020-05-01 Matias Tassano , Julie Delon , Thomas Veit

Low-dose positron emission tomography (PET) image reconstruction methods have potential to significantly improve PET as an imaging modality. Deep learning provides a promising means of incorporating prior information into the image…

Computer Vision and Pattern Recognition · Computer Science 2024-09-11 Cameron Dennis Pain , Yasmeen George , Alex Fornito , Gary Egan , Zhaolin Chen

Image reconstruction from computed tomography (CT) measurement is a challenging statistical inverse problem since a high-dimensional conditional distribution needs to be estimated. Based on training data obtained from high-quality…

Image and Video Processing · Electrical Eng. & Systems 2020-06-12 Alexander Denker , Maximilian Schmidt , Johannes Leuschner , Peter Maass , Jens Behrmann

A standard dose of radioactive tracer must be delivered into the patients body to obtain high-quality Positron Emission Tomography (PET) images for diagnostic purposes, which raises the risk of radiation harm. A reduced tracer dose, on the…

A deep convolutional neural network has been developed to denoise atomic-resolution TEM image datasets of nanoparticles acquired using direct electron counting detectors, for applications where the image signal is severely limited by shot…

This paper applies the recent fast iterative neural network framework, Momentum-Net, using appropriate models to low-dose X-ray computed tomography (LDCT) image reconstruction. At each layer of the proposed Momentum-Net, the model-based…

Image and Video Processing · Electrical Eng. & Systems 2020-09-10 Siqi Ye , Yong Long , Il Yong Chun

While various deep learning methods were proposed for low-dose computed tomography (CT) denoising, they often suffer from over-smoothing, blurring, and lack of explainability. To alleviate these issues, we propose a plug-and-play…

Image and Video Processing · Electrical Eng. & Systems 2024-03-12 Zhihao Chen , Tao Chen , Chenhui Wang , Chuang Niu , Ge Wang , Hongming Shan

PET is affected by statistical noise due to constraints on tracer dose and scan duration, impacting both diagnostic performance and quantitative accuracy. While deep learning (DL)-based PET denoising methods have been used to improve image…

Reconstruction of few-view x-ray Computed Tomography (CT) data is a highly ill-posed problem. It is often used in applications that require low radiation dose in clinical CT, rapid industrial scanning, or fixed-gantry CT. Existing analytic…

Image and Video Processing · Electrical Eng. & Systems 2019-10-15 Hyojin Kim , Rushil Anirudh , K. Aditya Mohan , Kyle Champley

Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image…

Image and Video Processing · Electrical Eng. & Systems 2023-10-12 Wenjun Xia , Yongyi Shi , Chuang Niu , Wenxiang Cong , Ge Wang

Objective: Computed Tomography (CT) has an important role to detect lung lesion related to Covide 19. The purpose of this work is to obtain diagnostic findings of Ultra-Low Dose (ULD) chest CT image and compare with routine dose chest CT.…

Sparse-view computed tomography (CT) can be used to reduce radiation dose greatly but is suffers from severe image artifacts. Recently, the deep learning based method for sparse-view CT reconstruction has attracted a major attention.…

Image and Video Processing · Electrical Eng. & Systems 2022-11-21 Wenjun Xia , Wenxiang Cong , Ge Wang

X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging but its radiation dose can be further improved. Despite the great potential of deep learning techniques, their application in HR…

‹ Prev 1 4 5 6 7 8 10 Next ›