English
Related papers

Related papers: A Portable Diagnostic Device for Cardiac Magnetic …

200 papers

We use magnetic-field-dependent features in the photoluminescence of negatively charged nitrogen-vacancy centers to measure magnetic fields without the use of microwaves. In particular, we present a magnetometer based on the level…

Mesoscale and Nanoscale Physics · Physics 2016-08-24 Arne Wickenbrock , Huijie Zheng , Lykourgos Bougas , Nathan Leefer , Samer Afach , Andrey Jarmola , Victor M. Acosta , Dmitry Budker

The engineering space for magnetically manipulated biomedical microrobots is rapidly expanding. This includes synthetic, bioinspired, and biohybrid designs, some of which may eventually assume clinical roles aiding drug delivery or…

Instrumentation and Detectors · Physics 2023-04-25 Michael G. Christiansen , Lucien Stöcklin , Cameron Forbrigger , Shashaank Abhinav Venkatesh , Simone Schuerle

Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the…

Accelerator Physics · Physics 2022-05-04 J. M. Nogiec , P. Akella , G. Chlachidze , J. DiMarco , M. Tartaglia , P. Thompson , K. Trombly-Freytag , D. Walbridge

Electrocardiogram (ECG) is an important non-invasive method for diagnosing cardiovascular disease. However, ECG signals are susceptible to noise contamination, such as electrical interference or signal wandering, which reduces diagnostic…

Signal Processing · Electrical Eng. & Systems 2024-11-26 Kuo-Hsuan Hung , Kuan-Chen Wang , Kai-Chun Liu , Wei-Lun Chen , Xugang Lu , Yu Tsao , Chii-Wann Lin

Nitrogen-vacancy (N-V) center in diamond provides a robust, solid-state platform for magnetic field measurements at room temperature. To harness its potential in inspecting inaccessible regions, here we present a compact endoscopic…

Instrumentation and Detectors · Physics 2025-10-22 Satbir Singh , Hyunjong Lee , Nhu Anh Nguyen , Seonghyeon Kang , Jeong Hyun Shim , Sangwon Oh , Kwang-Geol Lee

The negatively-charged NV$^-$-center in diamond has shown great success in nanoscale, high-sensitivity magnetometry. Efficient fluorescence detection is crucial for improving the sensitivity. Furthermore, integrated devices enable…

We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence…

Atomic Physics · Physics 2010-10-12 M. P. Ledbetter , V. M. Acosta , S. M. Rochester , D. Budker , S. Pustelny , V. V. Yashchuk

The human ear offers a unique opportunity for cardiac monitoring due to its physiological and practical advantages. However, existing earable solutions require additional hardware and complex processing, posing challenges for commercial…

Human-Computer Interaction · Computer Science 2025-01-14 Yongjian Fu , Ke Sun , Ruyao Wang , Xinyi Li , Ju Ren , Yaoxue Zhang , Xinyu Zhang

A research of inductive conductometric cell is presented. An equivalent circuit and a mathematical model of inductive cell are given in the article. The model takes into account sample-coil capacity (i.e. capacity formed by the coil and the…

Instrumentation and Detectors · Physics 2013-05-01 Yury S. Semenov

Low-cost spintronic devices functioning in zero applied magnetic field are required for bringing the idea of spin-based electronics into the real-world industrial applications. Here we present first microwave measurements performed on…

Mesoscale and Nanoscale Physics · Physics 2008-11-17 A. Mourachkine , O. V. Yazyev , C. Ducati , J. -Ph. Ansermet

We present a Scanning Hall Probe Microscope operating in ambient conditions. One of the unique features of this microscope is the use of the same stepper motors for both sample positioning as well as scanning, which makes it possible to…

Mesoscale and Nanoscale Physics · Physics 2017-12-12 Gorky Shaw , R. B. G. Kramer , N Dempsey , K Hasselbach

We characterize the performance of a system based on a magnetoresistor array. This instrument is developed to map the magnetic field, and to track a dipolar magnetic source in the presence of a static homogeneous field. The position and…

Non-contact vital sign monitoring has many advantages over conventional methods in being comfortable, unobtrusive and without any risk of spreading infection. The use of millimeter-wave (mmWave) radars is one of the most promising…

Signal Processing · Electrical Eng. & Systems 2023-09-18 Steven Marty , Federico Pantanella , Andrea Ronco , Kanika Dheman , Michele Magno

The electrocardiogram (ECG) signal is one of the most vital signals that can be used to investigate the performance of heart. Based on the ECG graph, we can identify different disorders and diseases. Therefore, monitoring this signal is of…

Signal Processing · Electrical Eng. & Systems 2023-02-22 Soheil Khooyooz , Mohammad Ali Ahmadi-Pajouh , Kamyab Azizi

The electrocardiogram (ECG) has always been an important biomedical test to diagnose cardiovascular diseases. Current approaches for ECG monitoring are based on body attached electrodes leading to uncomfortable user experience. Therefore,…

Signal Processing · Electrical Eng. & Systems 2022-11-22 Jinbo Chen , Dongheng Zhang , Zhi Wu , Fang Zhou , Qibin Sun , Yan Chen

Magnetic resonance imaging systems rely on signal detection via radiofrequency coil arrays which, ideally, need to provide both bendability and form-fitting stretchability to conform to the imaging volume. However, most commercial coils are…

Heart rate (HR) is a crucial physiological signal that can be used to monitor health and fitness. Traditional methods for measuring HR require wearable devices, which can be inconvenient or uncomfortable, especially during sleep and…

Measurements monitoring the inductive coupling between oscillating radio-frequency magnetic fields and objects of interest create versatile platforms for non-destructive testing. The benefits of ultra low frequency measurements, i.e., below…

Applied Physics · Physics 2024-10-17 L. M. Rushton , L. M. Ellis , J. D. Zipfel , P. Bevington , W. Chalupczak

In the development of any type of magnetic field sensor based on magnetic films, special consideration must be given to the magnetic layer component. The presented work investigates the use of flux closing magnetostrictive multilayers for…

Signal Processing · Electrical Eng. & Systems 2023-12-11 L. Thormählen , P. Hayes , E. Elzenheimer , E. Spetzler , J. McCord , G. Schmidt , M. Höft , D. Meyners , E. Quandt

Resonant inductive coupling is commonly seen as an undesired fundamental phenomenon emergent in densely packed resonant structures, such as nuclear magnetic resonance phased array detectors. The need to mitigate coupling imposes rigid…

Instrumentation and Detectors · Physics 2018-09-05 Bei Zhang , Daniel K. Sodickson , Martijn A. Cloos
‹ Prev 1 4 5 6 7 8 10 Next ›