Related papers: Proposal of Readout Electronics for CSNS-WNS BaF2 …
We introduce an efficient and accurate readout measurement scheme for single and multi-qubit states. Our method uses Bayesian inference to build an assignment probability distribution for each qubit state based on a reference…
Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-$Z$, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed…
On a very fundamental level, particle detectors share similar requirements for their read-out chain. This is reflected in the way that typical read-out solutions are developed, where a previous design is taken and modified to fit some…
A high precision beam monitor system based on silicon carbide PIN sensor is designed for China Spallation Neutron Source 1.6 GeV proton beam to monitor the proton beam fluence.The concept design of the beam monitor system is finished…
Constructing a quantum computer capable of broad and important applications is likely to require millions of addressable physical qubits, posing the challenge of large-scale integration of quantum systems with classical electronics. Fully…
The LHAASO (Large High Altitude Air Shower Observatory) experiment is proposed for very high energy gamma ray source survey, in which the WCDA (Water Cherenkov Detector Array) is the one of the major components. In the WCDA, a total of 3600…
Nitrogen-vacancy (NV) centres in diamond are a key platform for quantum sensing and quantum information, combining long coherence times with controllable spin-spin interactions. Most of current quantum algorithms rely on optical access,…
The Chinese large-area violet-light-sensitive silicon photodiode PIN is one of the candidates of the lead tungstate crystal detector readout component of the photon spectrometer in the large heavy ion collision experiment. The PIN diode was…
PandaX-4T is a dark matter direct detection experiment located in China jinping underground laboratory. The central apparatus is a dual-phase xenon detector containing 4 ton liquid xenon in the sensitive volume, with about 500…
We report on the assessment of the imaging performance of CITIUS -- a high-speed X-ray detector developed for the large-scale synchrotron radiation facility SPring-8-II -- for heavy charged particles and neutrons. To characterize the…
We introduce a frequency-multiplexed readout scheme for superconducting phase qubits. Using a quantum circuit with four phase qubits, we couple each qubit to a separate lumped-element superconducting readout resonator, with the readout…
High resolution calorimetry with state-of-the-art energy resolution performance for both electromagnetic (EM) and hadronic signals can be achieved using the dual-readout (DR) technique, both in a homogeneous scintillating-crystal…
NdO$_{0.5}$F$_{0.5}$BiS$_{2}$ is a new layered superconductor. We have studied the low-lying electronic structure of a single crystalline NdO$_{0.5}$F$_{0.5}$BiS$_{2}$ superconductor, whose superconducting transition temperature is 4.87K,…
Waveform digitizers are key readout instruments in particle physics experiments. In this paper, we present a waveform digitizer for the PandaX dark matter experiments. It supports both external-trigger readout and triggerless readout,…
A front-end readout electronics system has been developed for silicon strip detectors. The system uses an application specific integrated circuit (ASIC) ATHED to realize multi-channel E&T measurement. The slow control of ASIC chips is…
A new prototype wireless data acquisition system has been developed with the intended application to read-out instrumentation systems having a large number of channels. In addition such system could be deployed in smaller detectors…
A detailed investigation of BaNi2(As,P)2 single crystals using high-resolution thermal-expansion, heat-capacity,Young-modulus and resistivity measurements is presented. The experimental data are complemented by density-functional…
A prototype flash analog-to-digital readout system for cosmic ray detection at energies below 10^18 eV has been designed and tested at Columbia University Nevis Laboratories. The electronics consist of an FADC module that digitizes 16…
We propose and analyze a high fidelity readout scheme for a single instance approach to quantum computing in rare-earth-ion-doped crystals. The scheme is based on using different species of qubit and readout ions, and it is shown that by…
A new type of radiation detector based on a spherical geometry is presented. The detector consists of a large spherical gas volume with a central electrode forming a radial electric field. Charges deposited in the conversion volume drift to…