English
Related papers

Related papers: Polarization Sensitive Multi-Chroic MKIDs

200 papers

Microwave Kinetic Inductance Detectors (MKIDs) are a class of superconducting cryogenic detectors that simultaneously exhibit energy resolution, time resolution and spatial resolution. The pixel yield of MKID arrays is usually a critical…

Instrumentation and Methods for Astrophysics · Physics 2023-01-20 Mario De Lucia , E. Baldwin , G. Ulbricht , J. D. Piercy , O. Creaner , C. Bracken , T. P. Ray

The European Research Council has recently funded HOLMES, a project with the aim of performing a calorimetric measurement of the electron neutrino mass measuring the energy released in the electron capture decay of 163Ho. The baseline for…

Instrumentation and Detectors · Physics 2016-01-20 A. Giachero , P. K. Day , P. Falferi , M. Faverzani , E. Ferri , C. Giordano , M. Maino , B. Margesin , R. Mezzena , R. Nizzolo , A. Nucciotti , A. Puiu , L. Zanetti

Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory…

Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good…

Instrumentation and Methods for Astrophysics · Physics 2016-02-15 L. Bisigello , S. J. C. Yates , V. Murugesan , J. J. A. Baselmans , A. M. Baryshev

Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct…

Characterization of the minute cosmic microwave background polarization signature requires multi-frequency, high-throughput precision instrument systems. We have previously described the detector fabrication of a 40 GHz focal plane and now…

Microwave Kinetic Inductance Detectors (MKIDs) sensitive to light in the ultraviolet to near-infrared wavelengths are superconducting micro-resonators that are capable of measuring photon arrival times to microsecond precision and…

Instrumentation and Methods for Astrophysics · Physics 2022-07-04 Nicholas Zobrist , W. Hawkins Clay , Grégoire Coiffard , Miguel Daal , Noah Swimmer , Peter Day , Benjamin A. Mazin

We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the…

Instrumentation and Detectors · Physics 2013-11-18 R. M. J. Janssen , J. J. A. Baselmans , A. Endo , L. Ferrari , S. J. C. Yates , A. M. Baryshev , T. M. Klapwijk

Multichroic polarization sensitive detectors enable increased sensitivity and spectral coverage for observations of the Cosmic Microwave Background (CMB). An array optimized for dual frequency detectors can provide 1.7 times gain in…

Microwave kinetic inductance detectors (MKIDs) are thin film, cryogenic, superconducting resonators. Incident Cooper pair-breaking radiation increases their kinetic inductance, thereby measurably lowering their resonant frequency. For a…

Microwave Kinetic Inductance Detectors (MKIDs) provide highly multiplexed arrays of detectors that can be configured to operate from the sub-millimeter to the X-ray regime. We have examined two tungsten silicide alloys (W5Si3 and WSi2),…

This paper presents a new laboratory activity aimed at developing knowledge and expertise in microwave applications at cryogenic temperatures. The experience focuses on the detection of infrared photons through Microwave Kinetic Inductance…

NIKA is a dual-band camera operating with 315 frequency multiplexed LEKIDs cooled at 100 mK. NIKA is designed to observe the sky in intensity and polarisation at 150 and 260 GHz from the IRAM 30-m telescope. It is a test-bench for the final…

Large ultra-sensitive detector arrays are needed for present and future observatories for far infra-red, submillimeter wave (THz), and millimeter wave astronomy. With increasing array size, it is increasingly important to control stray…

The Keck Array (SPUD) began observing the cosmic microwave background's polarization in the winter of 2011 at the South Pole. The Keck Array follows the success of the predecessor experiments Bicep and Bicep2, using five on-axis refracting…

For space observatories, the glitches caused by high energy phonons created by the interaction of cosmic ray particles with the detector substrate lead to dead time during observation. Mitigating the impact of cosmic rays is therefore an…

Instrumentation and Methods for Astrophysics · Physics 2019-01-28 K. Karatsu , A. Endo , J. Bueno , P. J. de Visser , R. Barends , D. J. Thoen , V. Murugesan , N. Tomita , J. J. A. Baselmans

Kinetic inductance detectors are widely used in millimeter- and submillimeter-wave astronomy, benefiting from their fast response and relative ease of fabrication. The GroundBIRD telescope employs microwave kinetic inductance detectors at…

Instrumentation and Methods for Astrophysics · Physics 2026-03-10 Yonggil Jo , Alessandro Fasano , Eunil Won , Makoto Hattori , Shunsuke Honda , Chiko Otani , Junya Suzuki , Mike Peel , Kenichi Karatsu , Ricardo Génova-Santos , Miku Tsujii

Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this…

We are developing multi-chroic antenna-coupled TES detectors for CMB polarimetry. Multi-chroic detectors increase the mapping speed per focal plane area and provide greater discrimination of polarized galactic foregrounds with no increase…