Related papers: Beam Test Results of High Q CBPM prototype for SXF…

200 papers

This paper reports the design and cold test of the cavity beam position monitor (CBPM) for SX-FEL to fulfill the requirement of beam position measurement resolution of less than 1{\mu}m, even 0.1{\mu}m. The CBPM was optimized by using a…

Accelerator Physics · Physics 2015-06-17 Renxian Yuan , Weimin Zhou , Zhichu Chen , Luyang Yu , Baopen Wang , Yongbin Leng

In order to pursue high-precision beam position measurements for the free-electron laser (FEL) facilities, cavity beam position monitor (CBPM) is employed to measure the transverse position which can meet the requirement of position…

Accelerator Physics · Physics 2017-04-14 Jian Chen , Yong-bin Leng , Lu-yang Yu , Long-wei Lai , Ren-xian Yuan

The undulator line of the Shanghai soft X-ray Free-electron Laser facility (SXFEL) has very tight tolerances on the straightness of the electron beam trajectory. However, the beam trajectory cannot meet the lasing requirements due to the…

Accelerator Physics · Physics 2021-08-27 Liang Xu , Nanshun Huang , Qingmin Zhang , Duan Gu , Haixiao Deng

BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter…

Instrumentation and Detectors · Physics 2019-09-30 Weihao Wu , Lei Zhao , Erlei Chen , Shubin Liu , Qi An

The nano-meter beam size in future linear colliders requires very high resolution beam position monitor since higher resolution allows more accurate position measurement in the interaction point. We developed and tested a low-Q C-band beam…

Cavity-based x-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard x-ray sources having high spectral brilliance along with a narrow spectral bandwidth of $\simeq 1 - 50$~meV, a high repetition pulse…

Optics · Physics 2025-03-25 Keshab Kauchha , Peifan Liu , Paresh Pradhan , Yuri Shvyd'ko

The control of beam phase relative to the accelerating RF field within a superconducting cavity is important in many accelerator applications and is of particular importance for a free electron laser facility. As standard practice, the…

Accelerator Physics · Physics 2018-11-14 L. Shi , N. Baboi , R. M. Jones

The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the…

Higher order mode (HOM) beam position monitors (BPM) are being developed for the 3.9 GHz third harmonic superconducting accelerating cavities at FLASH. The transverse beam position in a cavity can be determined utilizing beam-excited HOMs…

Accelerator Physics · Physics 2013-05-23 P. Zhang , N. Baboi , T. Flisgen , U. van Rienen , R. M. Jones , I. R. R. Shinton

Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…

As an important measure of improving the efficiency and usability of X-ray free electron laser facilities, simultaneous operation of multiple undulator lines realized by a beam distribution system has become a standard configuration in the…

Accelerator Physics · Physics 2022-04-25 Si Chen , Kaiqing Zhang , Tao Liu , Chao Feng , Haixiao Deng , Bo Liu , Zhentang Zhao

Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at…

Accelerator Physics · Physics 2012-08-13 P. Zhang , N. Baboi , N. Eddy , B. Fellenz , R. M. Jones , B. Lorbeer , T. Wamsat , M. Wendt

Shanghai Coherent Light Facility (SCLF) is a quasi-CW hard X-ray free electron laser user facility which is recently proposed. Due to the high repetition rate, high quality electron beams, it is straightforward to consider an X-ray free…

Accelerator Physics · Physics 2018-05-09 Kai Li , Haixiao Deng

An introduction and the status of R&D activities for a high-resolution, "cold" beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and…

Accelerator Physics · Physics 2009-02-19 M. Wendt , T. Lefevre , C. Simon , S. Vilalte

Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of…

Instrumentation and Detectors · Physics 2019-08-17 LI Hua-Peng , Kun Tang , Yi-Dong Zhao , Lei Zheng , Shu-Hu Liu , Xiao-Liang Zhao , Ya-Shuai Zhao

The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose close to or inside all sub-detectors. It is composed of…

Instrumentation and Detectors · Physics 2014-11-20 A. Bell , E. Castro , R. Hall-Wilton , W. Lange , W. Lohmann , A. Macpherson , M. Ohlerich , N. Rodriguez , V. Ryjov , R. S. Schmidt , R. L. Stone

Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated…

Accelerator Physics · Physics 2012-10-16 Nicoleta Baboi , Bastian Lorbeer , Pei Zhang , Nathan Eddy , Brian Fellenz , Manfred Wendt

The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of $10^{-4}$ or better. To achieve this goal a magnetic spectrometer using high…

There is growing interest in high-energy astrophysics community for the development of sensitive instruments in the hard X-ray energy extending to few hundred keV. This requires position sensitive detector modules with high efficiency in…

One-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of…