This paper reports the design and cold test of the cavity beam position monitor (CBPM) for SX-FEL to fulfill the requirement of beam position measurement resolution of less than 1{\mu}m, even 0.1{\mu}m. The CBPM was optimized by using a coupling slot to damp the TM010 mode in the output signal. The isolation of TM010 mode is about 117dB, and the shunt impedance is about 200{\Omega}@4.65GHz with the quality factor 80 from MAFIA simulation and test result. A special antenna was designed to load power for reducing excitation of other modes in the cavity. The resulting output power of TM110 mode was about 90mV/mm when the source was 6dBm, and the accomplishable minimum voltage was about 200{\mu}V. The resolution of the CBPM was about 0.1{\mu}m from the linear fitting result based on the cold test.

Keywords

Cite

@article{arxiv.1308.5503,
  title  = {Design and test of SX-FEL cavity BPM},
  author = {Renxian Yuan and Weimin Zhou and Zhichu Chen and Luyang Yu and Baopen Wang and Yongbin Leng},
  journal= {arXiv preprint arXiv:1308.5503},
  year   = {2015}
}

Comments

4 pages,9 figures