English
Related papers

Related papers: Improving the RPC rate capability

200 papers

The first Resistive Plate Chambers detectors were developed for cosmic ray experiments, where low rate capability, good time resolution and low cost per unit of area were needed. These same features, except for the low rate capability, were…

Instrumentation and Detectors · Physics 2020-01-29 R. Cardarelli , G. Aielli , E. Alunno Camelia , S. Bruno , A. Caltabiano , P. Camarri , A. Di Ciaccio , B. Liberti , L. Massa , L. Pizzimento , A. Rocchi

The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to…

The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The…

Instrumentation and Detectors · Physics 2021-08-31 Quanyin Li , Xiangyu Xie , Zhengwei Xue , Jiajin Ge , Yongjie Sun

This paper reports on the performance of Resistive Plate Chambers (RPCs) as function of the gas flow rate through the chambers and of environmental conditions, such as atmospheric pressure, ambient temperature and air humidity. The chambers…

Instrumentation and Detectors · Physics 2010-05-07 Burak Bilki , John Butler , Ed May , Georgios Mavromanolakis , Edwin Norbeck , Jose Repond , David Underwood , Lei Xia , Qingmin Zhang

The requirement of high rate capability for operation at LHC, led 20 years ago to the achievement of Resistive Plate Chambers operated in avalanche mode, thanks to the introduction of new gas mixtures and to the development of the Front-End…

Instrumentation and Detectors · Physics 2017-06-28 A. Paoloni , A. Mengucci , M. Spinetti , M. Ventura , L. Votano

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

Resistive Plate Chambers (RPCs) exhibit a significant loss of efficiency for the detection of particles, when subjected to high particle fluxes. This rate limitation is related to the usually high resistivity of the resistive plates used in…

Instrumentation and Detectors · Physics 2015-09-08 M. Affatigato , U. Akgun , B. Bilki , F. Corriveau , B. Freund , N. Johnson , C. Neubueser , Y. Onel , J. Repond , L. Xia

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

This paper studies the performance of RPCs working with a new family of environment-friendly operating gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement…

Instrumentation and Detectors · Physics 2022-05-18 G. Proto , B. Liberti , R. Santonico , G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , A. Paoloni , E. Pastori , L. Pizzimento , A. Rocchi

The Multigap Resistive Plate Chamber (MRPC) is a gaseous detector; the performance depends very much on the gas mixture as well as the design. MRPCs are used as a timing device in several collider experiments and cosmic ray experiments…

Instrumentation and Detectors · Physics 2019-03-27 Yongwook Baek , Dowon Kim , M. C. S. Williams

This communication describes test beam results, focusing on detection efficiency and timing precision, of common float glass timing Resistive Plate Chambers (tRPCs) exposed to a $2.7$~GeV proton beam and operated at above ambient…

Instrumentation and Detectors · Physics 2022-11-23 A. Blanco , P. Fonte , L. Lopes , J. Saraiva

Principles of operation, construction and first test results of a Dielectric Resistive Plate Chamber (DRPC) are described. The detector has shown stability of operation in the avalanche mode of gas amplfication within a wide range of…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , A. Smirnitskiy , K. Voloshin

Resistive plate chamber (RPC) is one of the state-of-the-art particle detection technology for the High Energy Physics (HEP) experiments. The basic operating mechanism of an RPC involves ionization of gas due to the passage of charged…

Instrumentation and Detectors · Physics 2020-12-30 Tanay Dey , Supratik Mukhopadhyay , Subhasis Chattopadhyay , Jhilam Sadukan

Thin-gap Resistive Plate Chambers (RPCs) with a 1 mm gap size are introduced in the Phase-II ATLAS upgrade. Smaller avalanche charge due to the reduced gap size raises concerns for signal integrity. This work focuses on the RPC signal…

Instrumentation and Detectors · Physics 2023-04-11 Zirui Liu , Xiangyu Xie , Pingxin Zhang , Chunhao Tian , Yongjie Sun

The standard gas mixture for the Resistive Plate Chambers (RPC), composed of C2H2F4/i-C4H10/SF6, allows the detector operation in avalanche mode, as required by the high-luminosity collider experiments. The gas density, the low current and…

Instrumentation and Detectors · Physics 2025-03-10 Giorgia Proto

Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…

Instrumentation and Detectors · Physics 2023-07-19 Mehmet Tosun , Burak Bilki , Kutlu Kagan Sahbaz

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

In recent years, the Resistive Cylindrical Chamber (RCC) has been introduced as a novel gaseous detector, extending the well-established Resistive Plate Chambers (RPCs) to the case of cylindrical electrode geometry. Preliminary experimental…

High Energy Physics - Experiment · Physics 2025-10-08 M. Abbrescia , M. De Serio , S. Colafranceschi , B. Liberti , S. Meola , A. Paoloni , A. Pastore , D. Piccolo , A. Rocchi , G. Saviano , C. Vendittozzi

Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreater$~90\%) and time resolution ($\sim$~1-2~ns). Generally,…

Instrumentation and Detectors · Physics 2025-03-21 A. Sen , S. Mandal , S. Chatterjee , S. Gope , S. Das , S. Biswas

Resistive Plate Chambers (RPCs) have traditionally operated with high Global Warming Potential (GWP) gas mixtures, adding to the environmental footprint of large-scale physics experiments. In response, efforts are underway to explore…

Instrumentation and Detectors · Physics 2025-06-23 Aashaq Shah , Thomas Adolphus , Yingchang Zhang , Oleg Brandt
‹ Prev 1 2 3 10 Next ›