English
Related papers

Related papers: Outdoor Field Experience with Autonomous RPC Based…

200 papers

Large area arrays composed by dispersed stations are of major importance in experiments where Extended Air Shower (EAS) sampling is necessary. In those dispersed stations is mandatory to have detectors that requires very low maintenance and…

We report on the behaviour of Resistive Plate Chambers (RPC) developed for muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs were developed for the MARTA project and were tested on field conditions. These RPCs…

Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been…

Instrumentation and Detectors · Physics 2022-11-30 João Saraiva , Carlos Alemparte , Daniel Belver , Alberto Blanco , Juan Callón , Jose Collazo , Alfredo Iglesias , Luís Lopes

The mitigation of human-induced climate change is of crucial importance for the sustainability of humankind. For this aim the RPC community has exerted considerable effort over the last decade to reduce the emission of greenhouse gases from…

Instrumentation and Detectors · Physics 2020-12-30 L. Lopes P. Assis , A. Blanco , P. Fonte , M. Pimenta

The phase-out of hydro-fluorocarbons, owing to their high Global Warming Power, affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluoroethane C$_2$H$_2$F$_4$, has increased operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2024-03-01 A. Blanco , P. Fonte , L. Lopes , M. Pimenta

Resistive Plate Chambers (RPCs) are essential active media of large-scale experiments as part of the muon systems and (semi-)digital hadron calorimeters. Among the several outstanding issues associated with the RPCs, the loss of efficiency…

Instrumentation and Detectors · Physics 2023-07-19 Mehmet Tosun , Burak Bilki , Kutlu Kagan Sahbaz

Resistive Plate Chambers (RPCs) have traditionally operated with high Global Warming Potential (GWP) gas mixtures, adding to the environmental footprint of large-scale physics experiments. In response, efforts are underway to explore…

Instrumentation and Detectors · Physics 2025-06-23 Aashaq Shah , Thomas Adolphus , Yingchang Zhang , Oleg Brandt

A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the…

Instrumentation and Detectors · Physics 2021-11-30 Yousef Pezeshkian , Amir Kiyoumarsioskouei , Majid Ahmadpouri , Ghasem Ghorbani

This paper reports on the performance of Resistive Plate Chambers (RPCs) as function of the gas flow rate through the chambers and of environmental conditions, such as atmospheric pressure, ambient temperature and air humidity. The chambers…

Instrumentation and Detectors · Physics 2010-05-07 Burak Bilki , John Butler , Ed May , Georgios Mavromanolakis , Edwin Norbeck , Jose Repond , David Underwood , Lei Xia , Qingmin Zhang

Resistive gaseous detectors can be broadly defined as those operated in conditions where virtually no field lines exist that connect any two metallic electrodes sitting at different potential. This condition can be operationally recognized…

Instrumentation and Detectors · Physics 2015-06-05 Diego Gonzalez-Diaz , Archana Sharma

Resistive Plate Chamber detectors are largely used in current High Energy Physics experiments, typically operated in avalanche mode with large fractions of Tetrafluoroethane (C2H2F4), a gas recently banned by the European Union due to its…

Instrumentation and Detectors · Physics 2024-10-16 Luca Quaglia

Over the last two decades, the possibility of using RPCs in outdoors systems has increased considerably. Our group has participated in this effort having installed several systems and continues to work on their optimization, while…

The phase-out of Hydrofluorocarbons (HFCs), due to their high Global Warming Potential (GWP), affecting the main gas used in Resistive Plate Chambers (RPCs), tetrafluorethane C2H2F4, has created operational difficulties on existing systems…

Instrumentation and Detectors · Physics 2025-02-21 A. Blanco , Mário Carvalho , Susete Fetal , Luis Lopes , Telmo Paes , Joana Pinto , Paulo Fonte

Resistive Plate Chambers detectors are extensively used in several domains of Physics. In High Energy Physics, they are typically operated in avalanche mode with a high-performance gas mixture based on Tetrafluoroethane (C2H2F4), a…

Instrumentation and Detectors · Physics 2025-10-08 D. Ahmadi , M. Tytgat

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…

Instrumentation and Detectors · Physics 2016-08-03 G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , R. Iuppa , B. Liberti , L. Paolozzi , E. Pastori , R. Santonico , M. Toppi

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

Gaseous detectors have long been used by particle physics experiments at beamlines or standalone experiments. Recently, their low momentum threshold has made them interesting as active targets for long baseline neutrino experiments. To…

Instrumentation and Detectors · Physics 2019-11-13 Philip Hamacher-Baumann

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data…

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

‹ Prev 1 2 3 10 Next ›