English
Related papers

Related papers: Study of the breakdown voltage of SiPMs

200 papers

Characteristics improvement of photon/plasmon detectors have been the subject of several investigations in the area of plasmonic integrated circuits. Among different suggestions, Silicon-based Metal-Semiconductor-Metal (MSM) waveguides are…

Applied Physics · Physics 2019-01-31 Elahe Rastegar Pashaki , Hassan Kaatuzian , Abdolber Mallah Livani

Silicon Photomultipliers (SiPM), also so-called Solid State Photomultipliers (SSPM), are based on Geiger mode avalanche breakdown limited by strong negative feedback. SSPM can detect and resolve single photons due to high gain and ultra-low…

Instrumentation and Detectors · Physics 2012-03-30 S. Vinogradov

Optical parametric down-conversion (PDC) is a central tool in quantum optics experiments. The number of collected down-converted modes greatly affects the quality of the produced photon state. We use Silicon Photomultiplier (SiPM)…

Quantum Physics · Physics 2015-06-03 L. Dovrat , M. Bakstein , D. Istrati , A. Shaham , H. S. Eisenberg

A silicon photomultiplier (SiPM) array has been developed at FBK-irst having 32 channels and a dimension of 8.0 x 1.1 mm^2. Each 250 um wide channel is subdivided into 5 x 22 rectangularly arranged pixels. These sensors are developed to…

Instrumentation and Detectors · Physics 2010-03-04 R. Greim , H. Gast , T. Kirn , J. Olzem , G. Roper Yearwood , S. Schael , N. Zimmermann , G. Ambrosi , P. Azzarello , R. Battiston , C. Piemonte

We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor…

Instrumentation and Detectors · Physics 2020-01-23 Tyana Stiegler , Kareem Kazkaz , Erik Swanberg , Vladimir Mozin

Radiation damage to a Silicon Photomultiplier (SiPM), as it occurs during the lifetime of the planned CMS high-granularity calorimeter detector, increases the dark current and degrades the signal-to-noise separation for minimum-ionizing…

Instrumentation and Detectors · Physics 2026-05-29 Katjana Neumann , Massimiliano Antonello , Lukas Brinkmann , Erika Garutti , Jörn Schwandt

Radon is the main background source of dark matter and neutrino experiments. Radon concentration ($\rm mBq/m^3$) measurement by liquid scintillation detector is a highly sensitive method at low temperatures using silicon photomultipliers…

Instrumentation and Detectors · Physics 2022-11-23 C. Zhong , F. J. Luo , B. Zheng , X. D. Wang , M. Y. Bu , J. Zou , M. N. Deng

The Hamamatsu UV-light enhanced 64-channel SiPM array of the newest generation (S13361-3050AS-08) has been examined for the purpose of being used for the Silicon Elementary Cell Add-on (SiECA) of the EUSO-SPB balloon experiment.…

Instrumentation and Methods for Astrophysics · Physics 2018-04-04 Max Renschler , William Painter , Francesca Bisconti , Andreas Haungs , Thomas Huber , Michael Karus , Harald Schieler , Andreas Weindl

We report on the characterization of near-ultraviolet high density silicon photomultiplier (\SiPM) developed at Fondazione Bruno Kessler (\FBK) at cryogenic temperature. A dedicated setup was built to measure the primary dark noise and…

Many of the characteristics of Silicon Photomultipliers (SiPMs), such as high Photon Detection Efficiency (PDE), are well matched to the requirements of the cameras of the Small-Sized Telescopes (SSTs) proposed for the Cherenkov Telescope…

Instrumentation and Methods for Astrophysics · Physics 2018-08-24 Giuseppe Romeo , Giovanni Bonanno , Giorgia Sironi , Maria Cristina Timpanaro

Dark count rate and correlated noise rate are among the main parameters that characterize silicon photomultipliers (SiPM). Typically, these parameters are evaluated by applying approximate formulas, or by fitting specific models, to the…

Instrumentation and Detectors · Physics 2017-11-01 Enrico Junior Schioppa

Plastic scintillation detectors represent an efficient, cost-effective, customizable solution for assessment of gamma radiation fields in the context of nuclear security, environmental radiation survey, radiological and nuclear incidents…

Instrumentation and Detectors · Physics 2021-12-08 Paolo Tancioni , Ulisse Gendotti

Silicon photomultipliers (SiPMs) are increasingly favored for detecting near-UV, visible, and infrared light in space due to their high sensitivity to single photons and compact design. While SiPMs offer several advantages over traditional…

Instrumentation and Methods for Astrophysics · Physics 2025-09-23 Shideh Davarpanah for the NUSES Collaboration

Number-resolving single photon detectors are essential for the implementation of numerous innovative quantum information schemes. While several number-discriminating techniques have been previously presented, the Silicon Photo-Multiplier…

Quantum Physics · Physics 2015-05-30 L. Dovrat , M. Bakstein , D. Istrati , H. S. Eisenberg

During the dielectric breakdown process of thin solid-state nanopores, the application of high voltages may cause the formation of multi-nanopores on one chip, which number and sizes are important for their applications. Here, simulations…

Chemical Physics · Physics 2024-10-30 Yinghua Qiu , Long Ma , Zhe Liu , Hongwen Zhang , Bowen Ai , Xinman Tu

The use of silicon photomultipliers (SiPMs) to detect light signals in highly radioactive environments presents several challenges, particularly due to their sensitivity on radiation, temperature, and overvoltage, requiring a proper…

Instrumentation and Detectors · Physics 2024-07-09 Paolo Carniti , Claudio Gotti , Gianluigi Pessina

Recent developments in photo-detectors and photo-detector systems are reviewed. The main emphasis is made on Silicon Photo-Multipliers (SiPM) - novel and very attractive photo-detectors. Their main features are described. Properties of…

Instrumentation and Detectors · Physics 2009-06-23 M. Danilov

The operation of large arrays of silicon photomultipliers (SiPM) in tanks of noble liquids requires low noise, low power front-end amplifiers, able to operate reliably in the cryogenic environment. A suitable amplifier needs to be paired…

Instrumentation and Detectors · Physics 2023-10-09 P. Carniti , E. Cristaldo , A. Falcone , C. Gotti , G. Pessina , F. Terranova

The last decade has increasingly seen the use of silicon photomultipliers (SiPMs) instead of photomultiplier tubes (PMTs). This is due to various advantages of the former on the latter like its smaller size, lower operating voltage, higher…

The temperature of a nonneutral plasma confined in a Penning-Malmberg trap can be determined by slowly lowering one side of the trap's electrostatic axial confinement barrier; the temperature is inferred from the rate at which particles…

Instrumentation and Detectors · Physics 2020-10-26 E. D. Hunter , J. Fajans , N. A. Lewis , A. P. Povilus , C. Sierra , C. So , D. Zimmer