Related papers: A measurement method of a detector response functi…
Methods of gamma-gamma, gamma-electron luminosities measurement at photon colliders based on Compton scattering of laser photons on high energy electrons at linear colliders are considered.
This paper, presents a simple method for accurate calibration of organic scintillation detectors. The method is based on the fact that differentiating the response function leads to accurate estimation of the Compton edge. The…
Compton scattering of a laser beam with a relativistic electron beam has been used to generate intense, highly polarized and nearly monoenergetic x-ray or gamma-ray beams at many facilities. The ability to predict the spatial, spectral and…
Scintillation detector has lower energy resolution for Gamma-ray as compared to semiconductor detector, better spectra analysis method is essential to traditional method. A model for describing the response function of scintillation…
Study of high energy cosmic events in the MeV range requires detector with high efficiency and energy resolution to be constructed. The present setup consisting of scintillator crystals CeBr3 with different thickness, each coupled with 12 x…
In this work, we report calculation for Compton scattering of a gamma-ray vortex with Laguerre Gaussian wave function on an electron in the framework of the relativistic quantum mechanics. We have found the following unexpected feature. The…
A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultiplier tube, and the corresponding…
Compton scattering is one of the dominant interaction processes in germanium for photons with an energy of around two MeV. If a photon scatters only once inside a germanium detector, the resulting event contains only one electron which…
Calibration of the absolute energy scale at high-energy photon (gamma-gamma, gamma-electron) colliders is discussed. The luminosity spectrum at photon colliders is broad and has a rather sharp high-energy edge, which can be used, for…
In order to cope with increasing lifetime radiation damage expected at collider experiments, silicon sensors are becoming increasingly thin. To achieve adequate detection efficiency, the next generation of detectors may have to operate with…
We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…
Gamma sources are routinely used to calibrate the energy scale and resolution of liquid scintillator detectors. However, non-scintillating material surrounding the source introduces energy losses, which may bias the determination of the…
Low-energy background through Compton scattering from the ambient $\gamma$ rays can be contaminated in direct dark matter search experiments. In this paper, we report comparable measurements on low-energy spectra via Compton scattering from…
An 800L liquid xenon scintillation $\gamma$ ray detector is being developed for the MEG experiment which will search for $\mu^+\to\mathrm{e}^+\gamma$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by…
Scintillation light from gamma ray irradiation in liquid xenon is detected by two Hamamatsu R9288 photomultiplier tubes (PMTs) immersed in the liquid. UV light reflector material, PTFE, is used to optimize the light collection efficiency.…
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up…
In this paper we investigate, with a detailed Monte-Carlo simulation based on Geant4, the novel approach [Nucl. Instrum. Methods A588 (2008) 457] to 3D imaging with photon scattering. A monochromatic and well collimated gamma beam is used…
An important source of background in direct searches for low-mass dark matter particles are the energy deposits by small-angle scattering of environmental $\gamma$ rays. We report detailed measurements of low-energy spectra from Compton…
A Compton camera is the most promising approach for gamma-ray detection in the energy region from several hundred keV to MeV, especially for application in high energy astrophysics. In order to obtain good angular resolution, semiconductor…
We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and…