Related papers: A measurement method of a detector response functi…
Measurement of gamma-ray polarization can provide valuable insight in different areas of physics. A possible application is in Positron Emission Tomography, where annihilation quanta with orthogonal polarizations are emitted. Since…
A novel method for localization and estimation of compact sources of gamma radiation for Micro Aerial Vehicles (MAVs) is presented in this paper. The method is developed for a novel single-detector Compton camera, developed by the authors.…
In the evaluation of novel scintillators, it is important to ensure that the spectrum of the light emitted by the scintillator is well matched to the response of the photomultiplier. In attempting to measure this spectrum using radioactive…
A new and simple technique has been developed using plastic scintillator detectors for gamma ray and cosmic ray spectroscopy without single channel analyzer (SCA) or multichannel analyzer (MCA). In these experiments only a leading edge…
Diverse searches for direct dark matter (DM) in effective electromagnetic and leptophilic interactions resulting from new physics, as well as Weakly Interacting Massive Particles (WIMPs) with unconventional electronic recoils, are…
A novel, non-invasive method of measuring the beam energy at the International Linear Collider is proposed. Laser light collides head-on with beam particles and either the energy of the Compton scattered electrons near the kinematic…
We have measured the energy dependence of the liquid xenon (LXe) scintillation yield of electrons with energy between 2.1 and 120.2keV, using the Compton coincidence technique. A LXe scintillation detector with a very high light detection…
A simple model for the estimation of the light yield of a scintillation detector is developed under general assumptions and relying exclusively on the knowledge of its optical properties. The model allows to easily incorporate effects…
A high-brilliance ($\sim10^{24}$~photon.s$^{-1}$.mm$^{-2}$.mrd$^{-2}$/0.1\%) gamma-ray source experiment is currently being planned at Fermilab ($E_\gamma\simeq 1.1$~MeV)~[1]. The source implements a high-repetition-rate inverse Compton…
Scintillator detector response modelling has become an essential tool in various research fields such as particle and nuclear physics, astronomy or geophysics. Yet, due to the system complexity and the requirement for accurate electron…
KEDR detector has the tagging system (TS) to study the gamma-gamma processes. To determine the two-photon invariant mass, the energies of the scattered at small angles electrons and positrons are measured by the magnetic spectrometer…
An experimental setup for studying the Compton scattering of annihilation photons in various (entangled and decoherent) quantum states is presented. Two entangled $\gamma$-quanta with an energy of 511 keV and mutually orthogonal…
The energetic bremsstrahlung photons up to 100 MeV produced in heavy ion collisions can be used as a sensitive probe to the short range correlation in atomic nuclei. The energy of the $\gamma$-rays can be measured by collecting the…
The cross section of atomic electron Compton scattering $\gamma + e \rightarrow \gamma^\prime + e^\prime $ was measured in the 4.40--5.475 GeV photon beam energy region by the {\em PrimEx} collaboration at Jefferson Lab with an accuracy of…
Compton scattering of photons off high-energy electrons is a fundamental quantum mechanical process widely utilized to produce a $\gamma$-ray beam for scientific research. Instead of injecting laser light into a storage ring as a…
The beam energy measurement system for the VEPP-2000 electron-positron collider is described. The method of Compton backscattering of $CO$ laser photons on the electron beam is used. The relative systematic uncertainty of the beam energy…
Detection of $\gamma$-ray polarization in Positron Emission Tomography (PET) is as yet an unexploited feature that could be used as an additional handle to improve signal-to-background ratio in this imaging modality. The $\gamma$…
The response of the liquid scintillator (EJ-301 equivalent to NE-213) to the monoenergetic electrons produced in Compton scattered $\gamma$-ray tagging has been carried out for various radioactive $\gamma$-ray sources. The measured electron…
A novel design for a compact gamma-ray spectrometer is presented. The proposed system allows for spectroscopy of high-flux multi-MeV gamma-ray beams with MeV energy resolution in a compact design. In its basic configuration, the…
Accurate energy channel calibration in scintillation detectors is essential for reliable radiation detection across nuclear physics, medical imaging, and environmental monitoring. Organic scintillators like BC408 and EJ309 lack full-energy…