Tl$_2$LiYCl$_6$:Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse-shape discrimination (PSD). It has a higher density and Z-number than the more mature and…

Instrumentation and Detectors · Physics 2020-04-22 M. M. Watts , K. E. Mesick , K. D. Bartlett , D. D. S. Coupland

Scintillators capable of detecting both neutrons and gamma-rays have generated considerable interest. In particular, the use of such scintillators with silicon photomultipliers (SiPMs) enables low-power and compact-geometry applications.…

Instrumentation and Detectors · Physics 2018-08-29 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith

Cs$_2$LiYCl$_6$:Ce$^{3+}$ (CLYC) is a new scintillator that is an attractive option for applications requiring the ability to detect both gamma rays and neutrons within a single volume. It is therefore of interest in applications that…

Instrumentation and Detectors · Physics 2018-10-16 K. E. Mesick , D. D. S. Coupland , S. F. Nowicki , L. C. Stonehill

Silicon photomultipliers (SiPMs) are a good alternative to photomultiplier tubes (PMTs) because their gain and quantum efficiency are comparable to PMTs. However, the largest single-chip SiPM is still less than 1~cm$^2$. In order to use…

Instrumentation and Detectors · Physics 2017-11-17 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith

We have characterized two state-of-the-art solid-state photomultipliers, one by SensL, the other by Hamamatsu, coupled to scintillators by Saint-Gobain Crystals in the -25 to 50 degrees C temperature range. At room temperature, the energy…

Instrumentation and Detectors · Physics 2011-03-28 Clarisse Tur , Vladimir Solovyev , Jeremy Flamanc

In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and $\gamma$-ray Compton scatterer of the novel dual \g-ray and neutron imaging system GN-Vision, which aims at…

The first domestic inorganic scintillator CLYC was grown in Beijing Glass Research Instituteusing the vertical Bridgman method. In this work, we evaluated the performance of this new CLYC crystal in terms of gamma-ray energy resolution and…

Instrumentation and Detectors · Physics 2016-09-01 Li Kui-Nian , Zhang Xian-Peng , Gui Qiang , Jin Peng , Tian Geng

The Cs$_2$LiYCl$_6$:Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good $\gamma$-ray energy resolution. While the $^{35}$Cl($n,p$) reaction has been identified as a potential means for…

Instrumentation and Detectors · Physics 2024-09-23 J. A. Brown , B. L. Goldblum , J. M. Gordon , T. A. Laplace , T. S. Nagel , A. Venkatraman

The fast neutrons produced by a calibrated 241Am-Be source were detected by two different Cs2LiYCl6:Ce (CLYC) scintillator detectors. The two cylindrical crystals (1"x1" in size) were enriched with more than 99% of 7Li (C7LYC) and with…

Instrumentation and Detectors · Physics 2018-07-31 N. Blasi , S. Brambilla , F. Camera , S. Ceruti , A. Giaz , L. Gini , F. Groppi , S. Manenti , A. Mentana , B. Million , S. Riboldi

We report on the scintillation characterization of a 1 cm^3 CsI(Tl) crystal coupled to a 6 x 6 mm^2 SiPM read out with a custom transimpedance amplifier at cryogenic temperatures. The crystal was prepared with optical-grade surfaces and…

Instrumentation and Detectors · Physics 2025-11-19 M. Mirzakhani , R. Mahapatra , M. Platt

Silicon photomultiplier (SiPM), as the core photoelectric sensor for coherent neutrino detection in low-temperature pure CsI, its working performance directly determines the measurement accuracy of the scintillator light yield. Our previous…

Instrumentation and Detectors · Physics 2025-10-29 Tao Liu , Xilei Sun , Fengjiao Luo , Jingbo Ye , Bo Zheng , Cong Guo , Zhilong Hou , Rongbin Zhou , Aiqin Gao , Lei Cao , Bo Zhang , Sijia Han

The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…

Instrumentation and Detectors · Physics 2023-02-01 B. Boxer , B. Godfrey , C. Grace , J. Johnson , R. Khandwala , M. Tripathi

Scintillation characteristics of a thallium doped sodium iodide (NaI(Tl)) crystal with a dimension of 0.6 x 0.6 x 2 cm3 are studied by attaching a silicon photomultiplier (SiPM) direct to the crystal over a temperature range from 93 to 300…

Instrumentation and Detectors · Physics 2022-03-02 H. Y. Lee , J. A. Jeon , K. W. Kim , W. K. Kim , H. S. Lee , M. H. Lee

A new comprehensive study on the Cs${_2}$ZrCl${_6}$ (CZC) crystal scintillating properties under different types of irradiation was performed over a wide temperature range from 5 to 300 K. The light yield (LY) at room temperature (RT),…

Large size detectors based on Cs2LiYCl6:Ce (CLYC) are capable of performing a combined $\gamma$-ray and neutron spectrometry and constitute a promising technology for a wide range of applications in nuclear and high energy physics. Due to…

Instrumentation and Detectors · Physics 2018-10-17 T. Martinez , A. Pérez de Rada , D. Cano-Ott , R. Santorelli , I. Bandac , P. Garcia Abia , A. R. Garcia , A. Ianni , B. Montes , L. Romero , D. Villamarin

Chromatic calorimetry (CCAL) analyses particle detection by utilizing scintillators with distinct emission wavelengths to measure the longitudinal energy deposition of particle showers in high-energy physics, improving particle…

High Energy Physics - Experiment · Physics 2025-09-12 Devanshi Arora

The analog hadron calorimeter for the International Linear Collider (ILC) of the CALICE collaboration utilized novel silicon detectors, the Sillicon Photomultipliers (SiPMs), for the detection of scintillation light coming from very small…

Instrumentation and Detectors · Physics 2012-11-28 Michal Tesař , Christian Jendrysik , Jelena Ninković , Frank Simon

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect…

Instrumentation and Detectors · Physics 2025-05-22 S. Borden , J. A. Detwiler , W. Pettus , N. W. Ruof

Silicon PhotoMultipliers (SiPM) are an excellent choice for the scintillator light readout at hadron calorimeters due to their insensitivity to magnetic fields, low operating voltages, low cost, compactness and mechanical endurance. They…

Instrumentation and Detectors · Physics 2020-01-29 V. Mikhaylov , F. Guber , A. Ivashkin , A. Kugler , V. Kushpil , S. Morozov , O. Svoboda , P. Tlusty

Scintillation at cryogenic temperatures can give rise to detectors with particle discrimination for rare-event searches such as dark matter detection. We present time-resolved scintillation studies of Caesium Iodide (CsI) under excitation…

Instrumentation and Detectors · Physics 2018-06-18 Michael Clark , Patrick Nadeau , Shane Hills , Christophe Dujardin , Philippe Di Stefano