Related papers: R&D on GEM Detectors for Forward Tracking at a Fut…
Micro-Pattern Gas Detectors (MPGDs) are extensively employed in modern high-energy and nuclear Physics experiments because of their excellent spatial resolution, high rate capability, and operational stability. Among these, the Gas Electron…
The Gas Electron Multiplier (GEM) is a new age detector, which can handle the high flux of particles. The GEM foil, which is constructed using 50$\mu$m highly insulating foil (Kapton/Apical) coated with 5$\mu$m layers of copper, on both…
The status of the R&D on the Cylindrical-GEM (CGEM) detector foreseen as Inner Tracker for KLOE-2, the upgrade of the KLOE experiment at the DAFNE phi-factory, will be presented. The R&D includes several activities: i) the construction and…
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of…
Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are…
The Beijing Spectrometer (BESIII) is an experimental setup located at the Beijing Electron Positron Collider (BEPCII). The recently approved ten-year extension of data acquisition for BESIII prompted an upgrade program for both the BEPCII…
In 2008, a triple GEM detector prototype with an area of ~2000 cm2 has been constructed, based on foils of 66*66 cm. GEMs of such dimensions had not been made before, and innovations to the existing technology were introduced to build this…
A prototype Gas Electron Multiplier (GEM) detector is under construction for medical imaging purposes. A single thick GEM of size 10x10 cm^2 is assembled inside a square shaped air-tight box which is made of Perspex glass. In order to…
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a sufficiently fine…
In this work we characterized a X-ray position sensitive gaseous detector based in a triple stack of gas electron multipliers (GEM). The readout circuit is divided in 256 strips for each dimension and using a resistive chain interconnecting…
The Cylindrical GEM-Inner Tracker (CGEM-IT) is the upgrade of the internal tracking system of the BESIII experiment. It consists of three layers of cylindrically-shaped triple GEMs, with important innovations with respect to the existing…
The Gas Electron Multiplier (GEM) has become a widely used technology for high-rate particle physics experiments like COMPASS, LHCb and are being used as the readout system for the upcoming upgrade version of other experiments such as ALICE…
The challenging physics program at the International Linear Collider (ILC) poses stringent requirements on the performance of its tracking system. A large volume time projection chamber (TPC) is considered a good candidate for such a…
For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM…
Modern time projection chambers are increasingly based on micro pattern gas detector readout systems. In this paper a self-supporting method used to mount Gas Electron Multiplier foils is presented. It is based on light weight ceramic…
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC…
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical \textsc{gem}s are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed.…
Results obtained with a triple GEM detector operated in pure CF4 with and without a reflective CsI photocathode are presented. The detector operates in a stable mode at gains up to 10^4. A deviation from exponential growth starts to develop…
Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of GEM foils, however with the…
The Large Hadron Collider is currently undergoing its High Luminosity upgrade, which is set to increase the instantaneous luminosity by about a factor of five. Consequently, the Compact Muon Solenoid experiment is upgrading its muon…