Conventional scanning tunneling microscopy (STM) is limited to a bandwidth of circa 1kHz around DC. Here, we develop, build and test a novel amplifier circuit capable of measuring the tunneling current in the MHz regime while simultaneously…

Applied Physics · Physics 2018-10-09 K. M. Bastiaans , T. Benschop , D. Chatzopoulos , D. H. Cho , Q. Dong , Y. Jin , M. P. Allan

Recently the doping of topological insulators has attracted significant interest as a potential route towards topological superconductivity. Because many experimental techniques lack sufficient surface sensitivity, however, a definite proof…

We have built a variable temperature scanning probe microscope (SPM) that covers 4.6 K - 180 K and up to 7 Tesla whose SPM head fits in a 52 mm bore magnet. It features a temperature-controlled sample stage thermally well isolated from the…

Instrumentation and Detectors · Physics 2017-11-22 Jin-Oh Jung , Seokhwan Choi , Yeonghoon Lee , Jinwoo Kim , Donghyun Son , Jhinhwan Lee

We describe the design and performance of a scanning tunneling microscope (STM) which operates at a base temperature of 30 mK in a vector magnetic field. The cryogenics is based on an ultra-high vacuum (UHV) top-loading wet dilution…

We introduce a statistical correlation analysis method to obtain information on the local geometry and orientation of the tip used in scanning tunneling microscopy (STM) experiments based on large scale simulations. The key quantity is the…

Materials Science · Physics 2015-03-17 Gábor Mándi , Gilberto Teobaldi , Krisztián Palotás

We present a robust but still efficient simulation approach for high-resolution scanning tunneling microscopy with a flexible tip apex showing sharp submolecular features. The approach takes into account the electronic structure of sample…

Mesoscale and Nanoscale Physics · Physics 2017-01-11 O. Krejci , P. Hapala , M. Ondracek , P. Jelinek

In the last decade, detecting spin dynamics at the atomic scale has been enabled by combining techniques like electron spin resonance (ESR) or pump-probe spectroscopy with scanning tunneling microscopy (STM). Here, we demonstrate an…

We report on a controlled method to fabricate in-situ a superconducting (SC) nanostructure at the apex of the standard W tip of a Scanning Tunnelling Microscope (STM) by pulsing the tunnelling voltage on a graphene covered metal surface. We…

The Planar Model of the Electrode-Vacuum-Electrode configuration for STM in which electrode surfaces are assumed to be infinite parallel planes, with atomic size separation and vacuum between them, is used to calculate tunneling current…

Other Condensed Matter · Physics 2023-01-04 Malati Dessai , Arun V. Kulkarni

The light emission rate from a scanning tunneling microscope (STM) scanning a noble metal surface is calculated taking retardation effects into account. As in our previous, non-retarded theory [Johansson, Monreal, and Apell, Phys. Rev. B…

Condensed Matter · Physics 2007-05-23 Peter Johansson

We propose an analytical formulation for the Scanning Gate Microscopy (SGM) response to local tips with arbitrary strength in two terminal nano-structures. The real space resolved conductance is expressed in terms of the unperturbed…

Mesoscale and Nanoscale Physics · Physics 2023-09-14 Ousmane Ly

We describe the construction and performance of a scanning tunneling microscope (STM) capable of taking maps of the tunneling density of states with sub-atomic spatial resolution at dilution refrigerator temperatures and high (14 T)…

Instrumentation and Detectors · Physics 2013-10-04 Shashank Misra , Brian B. Zhou , Ilya K. Drozdov , Jungpil Seo , Andras Gyenis , Simon C. J. Kingsley , Howard Jones , Ali Yazdani

We present a simple home made solution enabling in-situ RF reflectometry measurements with a millikelvin scanning tunneling microscope (mk-STM). The additions described below were made using RF best practices following similar detection…

Instrumentation and Detectors · Physics 2025-12-18 Jonathan Marbey , Michael Dreyer , R. E. Butera

Room-temperature and low-temperature (77 K) scanning tunneling spectroscopy (STS) and voltage-dependent scanning tunneling microscopy (STM) data are used to study the local electronic properties of the quasi-one-dimensional Si(557)-Au…

Mesoscale and Nanoscale Physics · Physics 2014-02-19 M. Sauter , R. Hoffmann , C. Surgers , H. v. Lohneysen

We present a scanning probe microscopy technique for spatially resolving transport in cold atomic gases, in close analogy with scanning gate microscopy in semiconductor physics. The conductance of a quantum point contact connected to two…

We present a detailed experimental study on the electrostatic interaction between a quantum dot and the metallic tip of a scanning force microscope. Our method allowed us to quantitatively map the tip-induced potential and to determine the…

Mesoscale and Nanoscale Physics · Physics 2009-11-13 A. E. Gildemeister , T. Ihn , M. Sigrist , K. Ensslin , D. C. Driscoll , A. C. Gossard

The Field Ion Microscope (FIM) can be used to characterize the atomic configuration of the apex of sharp tips. These tips are well suited for Scanning Probe Microscopy (SPM) since they predetermine SPM resolution and electronic structure…

Mesoscale and Nanoscale Physics · Physics 2012-08-07 William Paul , Yoichi Miyahara , Peter Grütter

We consider a scanning tunneling microscope (STM) such that tunneling occurs through two atomically sharp protrusions on its tip. When the two protrusions are separated by at least several atomic spacings, the differential conductance of…

Condensed Matter · Physics 2009-10-28 Michael E. Flatte' , Jeff M. Byers

Localized surface plasmon resonance (LSPR) excitation of nanostructures and charge transfer in plasmonic nanocavities plays a central role in nanoscale optoelectronics and in applications for plasmonic devices. However, the direct…

Mesoscale and Nanoscale Physics · Physics 2018-12-05 Shuyi Liu , Martin Wolf , Takashi Kumagai

Indium arsenide nanowires grown by selective-area vapor phase epitaxy are used as tips for scanning tunneling microscopy (STM). The STM tips are realized by positioning the wires manually on the corner of a double cleaved gallium arsenide…