English
Related papers

Related papers: High granularity tracker based on a Triple-GEM opt…

200 papers

The High Luminosity upgrade of the CERN Large Hadron Collider (HL-LHC) requires new high-radiation tolerant silicon pixel sensors for the innermost part of the tracking detector in the CMS experiment. The innermost layer of the tracker,…

High Energy Physics - Experiment · Physics 2025-02-11 Clara Lasaosa

The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…

Instrumentation and Detectors · Physics 2025-10-16 The Tracker Group of the CMS Collaboration

A simple X-ray imaging system using off-the-shelf electronics and simple reconstruction algorithms aiming a spatial resolution of 1.7 mm ($\sim 3\,\%$ of the detector length) is described in this work. For this, two 100 cm$^2$ Gas Electron…

Instrumentation and Detectors · Physics 2015-06-18 H. Natal da Luz , J. A. Mir , X. Carvalho , J. M. F. dos Santos

We summarize the development of visible-sensitive gaseous photomultipliers, combining a semitransparent bi-alkali photocathode with a state-of-the-art cascaded electron multiplier. The latter has high photoelectron collection efficiency and…

Instrumentation and Detectors · Physics 2009-07-23 A. V. Lyashenko , A. Breskin , R. Chechik , J. M. F. Dos Santos , F. D. Amaro , J. F. C. A. Veloso

Multiple-GEM detectors are considered to be good candidates for tracking devices in experiments with high hadronic background. We present the results of the triple-GEM detectors beam test in a high intensity pion beam. The detectors had an…

Instrumentation and Detectors · Physics 2007-05-23 A. Bondar , A. Buzulutskov , L. Shekhtman , A. Sokolov , A. Vasiljev

One of our two methods for fast-neutron imaging with spectrometric capability is presented here. It is a neutron-counting technique based on a hydrogenous neutron converter coupled to Gaseous Electron Multipliers (GEM). The principles of…

Instrumentation and Detectors · Physics 2009-11-10 V. Dangendorf , A. Breskin , R. Chechik , M. Goldberg , G. Laczko , I. Mor , M. Reginatto , D. Vartsky

Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal pattern. However, the collection of the charge cloud from the…

Physical principles of performance and main characteristics of a novel avalanche photodetector developed on the basis of MOS(metal-oxide-silicon) technology is presented. The photodetector contains a semitransparent gate electrode and a…

High Energy Physics - Experiment · Physics 2007-05-23 Z. Ya. Sadygov , M. K. Suleimanov , T. Yu. Bokova

High-resolution 3D tracking with sub-nanosecond timing is required for the detection of elementary particles, such as neutrinos. Conventional detectors, which utilize analog silicon photomultipliers, face challenges in balancing spatial…

Instrumentation and Detectors · Physics 2025-11-24 Kodai Kaneyasu , Till Dieminger , Matthew Franks , Davide Sgalaberna , Claudio Bruschini , Edoardo Charbon

CMOS Pixel Sensors tend to become relevant for a growing spectrum of charged particle detection instruments. This comes mainly from their high granularity and low material budget. However, several potential applications require a higher…

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…

High Energy Physics - Experiment · Physics 2015-06-25 T. Nagayoshi , H. Kubo , K. Miuchi , A. Ochi , R. Orito , A. Takada , T. Tanimori , M. Ueno

We discuss recent advances in the development of cryogenic gaseous photomultipliers (GPM), for possible use in dark matter and other rare-event searches using noble-liquid targets. We present results from a 10 cm diameter GPM coupled to a…

Instrumentation and Detectors · Physics 2015-10-28 L. Arazi , A. E. C. Coimbra , E. Erdal , I. Israelashvili , M. L. Rappaport , S. Shchemelinin , D. Vartsky , J. M. F. dos Santos , A. Breskin

Muon Tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons in matter is a promising technique for detecting heavily shielded high-Z radioactive materials (U, Pu) in cargo or vehicles. The technique uses…

Instrumentation and Detectors · Physics 2015-11-26 Kondo Gnanvo , Leonard V. Grasso , Marcus Hohlmann , Judson B. Locke , Amilkar S. Quintero , Debasis Mitra

Study of the stability of gain and energy resolution for a triple GEM detector has been performed under continuous radiation of X-ray with high rate, using premixed gas of Argon and CO$_2$ in 70/30 ratio and conventional NIM electronics. A…

Instrumentation and Detectors · Physics 2018-04-10 S. Roy , S. Rudra , S. Shaw , R. P. Adak , S. Biswas , S. Das , S. K. Ghosh , S. K. Prasad , S. Raha

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…

Instrumentation and Detectors · Physics 2008-11-26 A. Di Mauro , B. Lund-Jensen , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , L. Periale , P. Picchi , F. Pietropaolo , I. Rodionov , J. C. Santiard

Operation results are presented of a UV-sensitive gaseous photomultiplier (GPM) coupled through a MgF2 window to a liquid-xenon scintillator. It consisted of a reflective CsI photocathode deposited on top of a THick Gaseous Electron…

We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…

We describe a novel gaseous detector concept for heavy-ion tracking and imaging: the Optical Parallel-Plate Avalanche Counter (O-PPAC). The detector consists of two thin parallel-plate electrodes separated by a small (typically 3 mm) gap…

Instrumentation and Detectors · Physics 2018-10-17 Marco Cortesi , Yassid Ayyada , John Yurkon
‹ Prev 1 3 4 5 6 7 10 Next ›