English
Related papers

Related papers: High-Rate Capable Floating Strip Micromegas

200 papers

We present the performance of multiplexed XY resistive Micromegas detectors tested in the CERN SPS 100 GeV/c electron beam at intensities up to 3.3 $\times$ 10$^5$ e$^- $/(s$\cdot$cm$^2$). So far, all studies with multiplexed Micromegas…

Micromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time…

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a…

A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at…

Instrumentation and Detectors · Physics 2015-06-03 F. J. Iguaz , E. Ferrer-Ribas , A. Giganon , I. Giomataris

Muon tomography based on the measurement of multiple scattering of atmospheric cosmic ray muons is a promising technique for detecting and imaging heavily shielded high-Z nuclear materials such as enriched uranium. This technique could…

Instrumentation and Detectors · Physics 2016-11-17 K. Gnanvo , B. Benson , W. Bittner , F. Costa , L. Grasso , M. Hohlmann , J. B. Locke , S. Martoiu , H. Muller , M. Staib , A. Tarazona , J. Toledo

During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense…

Instrumentation and Detectors · Physics 2015-01-21 T. Peltola

We present the design of a Faraday cup-like charged particle detector in a four quadrant configuration aimed at facilitating the alignment of low-intensity beams of exotic particles. The device is capable of assessing the current on the…

Instrumentation and Detectors · Physics 2024-02-13 Kilian Brenner , Michael Zimmermann , Maik Butterling , Andreas Wagner , Christoph Hugenschmidt , Francesco Guatieri

Multiwire and microstrip porous detectors have been developed and investigated for DC operation. The multiwire porous detector consists of anode wires, an Al cathode and a gap between them filled with porous CsI. The microstrip porous…

Instrumentation and Detectors · Physics 2007-05-23 M. P. Lorikyan

The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $\mu$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution…

The design of a detector based on MICROMEGAS (MICRO MEsh GAseous Structure) technology is presented. Our detector is characterized by a large active area of 398(\times)281 mm(^{2}), a pad read-out with 20(\times)22 mm(^{2}) segmentation,…

Instrumentation and Detectors · Physics 2016-08-15 L. Aphecetche , H. Delagrange , D. G. d'Enterria , M. Le Guay , X. Li , G. Martínez , M. J. Mora , P. Pichot , D. Roy , Y. Schutz

Printed circuit metasurfaces have attracted significant attention in the microwave community for their versatile wavefront manipulation capability. Despite their promising potential in telecommunications and radar applications, few…

Applied Physics · Physics 2021-04-08 Andreas E. Olk , Pierre E. M. Macchi , David A. Powell

The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton--proton collision data at sqrt(s) = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40…

Instrumentation and Detectors · Physics 2014-03-12 The CMS Collaboration

We evaluate the performances of a 100 um-thick silicon strip detector (SSD) with a 300 MeV proton beam and a 90Sr beta-ray source. Signals from the SSD have been read out using a VLSI chip. Common-mode noise, signal separation efficiency…

Instrumentation and Detectors · Physics 2007-05-23 T. Hotta , M. Fujiwara , T. Kinashi , Y. Kuno , M. Kuss , T. Matsumura , T. Nakano , S. Sekikawa , H. Tajima

New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6…

A novel gaseous two-dimensional imaging detector "Micro Pixel Chamber (micro-PIC)" has been developed. This detector is based on double sided printed circuit board (PCB). We have developed large area (10cm x 10cm) micro-PICs with 65536…

High Energy Physics - Experiment · Physics 2015-06-25 T. Nagayoshi , H. Kubo , K. Miuchi , A. Ochi , R. Orito , A. Takada , T. Tanimori , M. Ueno

This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and…

As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gaseous Detector family to improve their robustness or…

We propose a high-precision, fast, robust and cost-effective muon detector concept for an FCC-ee experiment. This design combines precision drift tubes with fast plastic scintillator strips to enable both spatial and timing measurements.…

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

High Energy Physics - Experiment · Physics 2009-11-10 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Atsuhiko Ochi , Reiko Orito , Atsushi Takada , Toru Tanimori , Masaru Ueno

Experiments like ATLAS at the HL-LHC or detectors at future hadron colliders need muon detectors with excellent momentum resolution up to the TeV scale both at the trigger and offline reconstruction levels. This requires muon tracking…