English
Related papers

Related papers: High-Rate Capable Floating Strip Micromegas

200 papers

A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to…

We report the calibration of a gaseous Time Projection Chamber based on Micromegas charge readout modules with cosmic ray muons, utilizing their penetrating power and relatively uniform energy deposition per unit length. Muon events were…

The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of…

Instrumentation and Detectors · Physics 2016-04-06 M. Deile , J. Dubbert , S. Horvat , O. Kortner , H. Kroha , A. Manz , S. Mohrdieck-Moeck , F. Rauscher , R. Richter , A. Staude , W. Stiller

In this study we investigate the stability limits of Micromegas detectors upon irradiation with alpha particles. The results are obtained with meshes with different optical transparency and geometry of wires. The measurements are performed…

Instrumentation and Detectors · Physics 2023-06-13 P. Gasik , T. Waldmann , L. Fabbietti , T. Klemenz , L. Lautner , B. Ulukutlu

Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has…

Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in particle physics experiments for their capabilities in particle tracking at high rates. Their excellent position resolutions are well known but their energy…

Instrumentation and Detectors · Physics 2011-07-19 T. Zerguerras , B. Genolini , V. Lepeltier , J. Peyre , J. Pouthas , P. Rosier

The gaseous Micromegas detector designed for the CERN Axion search experiment CAST, operated smoothly during Phase-I, which included the 2003 and 2004 running periods. It exhibited linear response in the energy range of interest (1-10keV),…

Instrumentation and Detectors · Physics 2008-11-26 S. Aune , T. Dafni , G. Fanourakis , E. Ferrer Ribas , T. Geralis , A. Giganon , Y. Giomataris , I. G. Irastorza , K. Kousouris , K. Zachariadou

A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…

Instrumentation and Detectors · Physics 2016-08-30 Dezső Varga , Gábor Nyitrai , Gergő Hamar , László Oláh

A new Micromegas manufacturing technique, based on kapton etching technology, has been recently developed, improving the uniformity and stability of this kind of readouts. Excellent energy resolutions have been obtained, reaching 11% FWHM…

The Muon ATLAS MicroMegas Activity (MAMMA) focuses on the development and testing of large-area muon detectors based on the bulk-Micromegas technology. These detectors are candidates for the upgrade of the ATLAS Muon System in view of the…

Instrumentation and Detectors · Physics 2011-11-03 George Iakovidis , Kostantinos Karakostas , Matthias Schott

The Muon ATLAS Micromegas Activity (MAMMA) focuses on the development and testing of large-area muon detectors based on the bulk-Micromegas technology. These detectors are candidates for the upgrade of the ATLAS Muon System in view of the…

Instrumentation and Detectors · Physics 2015-06-03 Georgios Iakovidis , Theodoros Alexopoulos , Georgios Tsipolitis

The PICOSEC Micromegas detector is a precise-timing gaseous detector that combines a Cherenkov radiator, a semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum…

The latest Micromesh Gas Amplification Structures (Micromegas) are achieving outstanding energy resolution for low energy photons, with values as low as 11% FWHM for the 5.9 keV line of $^{55}$Fe in argon/isobutane mixtures at atmospheric…

Instrumentation and Detectors · Physics 2015-05-13 T. Dafni , E. Ferrer-Ribas , I. Giomataris , Ph. Gorodetzky , F. Iguaz , I. G. Irastorza , P. Salin , A. Tomas

A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE…

We present a detailed study of an 8-channel $1\times1$ mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline.…

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…

Instrumentation and Detectors · Physics 2017-09-20 B. B. Wiggins , Varinderjit Singh , J. Vadas , J. Huston , T. K. Steinbach , S. Hudan , R. T. deSouza

A two-dimensional position-sensitive microchannel plate detector, with a {\O}100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent…

Instrumentation and Detectors · Physics 2018-08-01 Yuezhao Zhang , Deyang Yu , Junliang Liu , Liping Yang , Wei Wang , Xiaoxiao Li , Xiaona Zhu , Xiaoxun Song , Xinfei Hui , Wei Xi , Xin Li , Huiping Liu , Xiaohong Cai

The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in developing technologies for charged particle detection with accurate timing at high rates. The required accuracy follows…

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov…

The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD)…

Instrumentation and Detectors · Physics 2022-04-26 M. Dixit , D. Attie , A. Bellerive , K. Boudjemline , P. Colas , P. Giganon , I. Giomataris , V. Lepeltier , S. Liu , J. -P. Martin , K. Sachs , Y. Shin , S. Turnbull