English
Related papers

Related papers: GIOVE - A New Detector Setup for High Sensitivity …

200 papers

We describe a new high-purity germanium (HPGe) detector setup for low-background {\gamma}-ray spectrometry. The GeMSE facility (Germanium Material and meteorite Screening Experiment) is dedicated to material screening for rare event…

Instrumentation and Detectors · Physics 2017-01-06 M. v. Sivers , B. A. Hofmann , Å. V. Rosén , M. Schumann

The use of High Purity Germanium detectors operated in ionization mode at cryogenic temperatures is investigated as an external background mitigation solution for bolometers used in rare-event search experiments. A simple experimental setup…

High Energy Physics - Experiment · Physics 2025-09-05 Chloé Goupy , Stefanos Marnieros , Beatrice Mauri , Claudia Nones , Matthieu Vivier

We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A…

Recent progress on the development of very low noise high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended…

A new ultra low-level counting setup has been installed in the shallow-underground laboratory Felsenkeller in Dresden, Germany. It includes a high-purity germanium detector (HPGe) of 163\% relative efficiency within passive and active…

Instrumentation and Detectors · Physics 2023-02-09 S. Turkat , D. Bemmerer , A. Boeltzig , A. R. Domula , J. Koch , T. Lossin , M. Osswald , K. Schmidt , K. Zuber

Four ultra-low background germanium spectrometers, called GeTHU, have been installed at the first phase of China Jinping Underground Laboratory (CJPL-I), and served for material screening of dark matter and neutrino experiments. Recently, a…

Instrumentation and Detectors · Physics 2025-11-24 Jikai Chen , Zhi Zeng , Hao Ma , Jianping Cheng

The GeMSE (Germanium Material and meteorite Screening Experiment) facility operates a low-background HPGe crystal in an underground laboratory with a moderate rock overburden of 620$\,$m.w.e. in Switzerland. It has been optimized for…

High-purity germanium (HPGe) detectors used for low-background gamma ray spectrometry are usually operated under either a fairly low overburden of the order of one meter of water equivalent (mw.e.) or a high overburden of the order of…

Germanium ionization detectors with sensitivities as low as 100 eVee (electron-equivalent energy) open new windows for studies on neutrino and dark matter physics. The relevant physics subjects are summarized. The detectors have to measure…

We are currently setting up a facility for low-background gamma-ray spectrometry based on a HPGe detector. It is dedicated to material screening for the XENON and DARWIN dark matter projects as well as to the characterization of meteorites.…

Instrumentation and Detectors · Physics 2015-10-21 M. von Sivers , B. A. Hofmann , Å. V. Rosén , M. Schumann

The Boulby Underground Germanium Suite (BUGS) comprises three low background, high-purity germanium detectors operating in the Boulby Underground Laboratory, located 1.1 km underground in the north-east of England, UK. BUGS utilises three…

The status and plans of a research program on the development of ultra-low-energy germanium detectors with sub-keV sensitivities are reported. We survey the scientific goals which include the observation of neutrino-nucleus coherent…

High Energy Physics - Experiment · Physics 2008-11-26 Henry T. Wong

An infrastructure to characterize germanium detectors has been designed and constructed at the HADES Underground Research Laboratory, located in Mol (Belgium). Thanks to the 223m overburden of clay and sand, the muon flux is lowered by four…

In this work we present the characterization of a Broad Energy Germanium (BEGe) type High Purity Germanium (HPGe) detector, with a carbon fiber entrance window thickness of 0.6 mm and an active area of 6305 mm2, operated at shallow depth (~…

Instrumentation and Detectors · Physics 2023-10-20 O. Fawwaz , H. Shams , F. Arneodo , A. Di Giovanni

We describe the upgrade and performance of the high-purity germanium counting facility Gator, which is dedicated to low-background $\gamma$-ray spectrometry. Gator is operated at the Gran Sasso Underground Laboratory in Italy, at an average…

Instrumentation and Detectors · Physics 2022-08-24 G. R. Araujo , L. Baudis , Y. Biondi , A. Bismark , M. Galloway

Device of new type is suggested - germanium detector with internal amplification. Such detector having effective threshold about 10 eV opens up fresh opportunity for investigation of dark matter, measurement of neutrino magnetic moment, of…

High Energy Physics - Experiment · Physics 2011-04-15 A. S. Starostin , A. G. Beda

A new type of radiation detector, a p-type modified electrode germanium diode, is presented. The prototype displays, for the first time, a combination of features (mass, energy threshold and background expectation) required for a…

Nuclear Experiment · Physics 2011-05-12 P. S. Barbeau , J. I. Collar , O. Tench

Searches for new physics push experiments to look for increasingly rare interactions. As a result, detectors require increasing sensitivity and specificity, and materials must be screened for naturally occurring, background-producing…

Instrumentation and Detectors · Physics 2021-02-03 D. S. Leonard , I. S. Hahn , W. G. Kang , V. Kazalov , G. W. Kim , Y. D. Kim , E. K. Lee , M. H. Lee , S. Y. Park , E. Sala

A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices…

A new ultra-low background high-purity germanium (HPGe) detector has been installed at the Kamioka underground experimental site. The background count rate in the energy range from 40 keV to 2700 keV is about 25% lower than that of the…

Instrumentation and Detectors · Physics 2023-12-05 K. Ichimura , H. Ikeda , Y. Kishimoto , M. Kurasawa , A. A. Suzuki , Y. Gando , M. Ikeda , K. Hosokawa , H. Sekiya , H. Ito , A. Minamino , S. Suzuki
‹ Prev 1 2 3 10 Next ›