Related papers: MiX: A Position Sensitive Dual-Phase Liquid Xenon …

200 papers

NEXT-100 is an electroluminescent high pressure Time Projection Chamber currently under construction. It will search for the neutrino-less double beta decay in 136Xe at the Canfranc Underground Laboratory. NEXT-100 aims to achieve nearly…

Instrumentation and Detectors · Physics 2019-08-16 C. A. B. Oliveira

Dual-phase time projection chamber (TPC) that employs a multi-ton-scale liquid xenon (LXe) target mass is a pioneering detector technology to search for dark matter. Beyond its advantage in dark matter direct detection efforts, the natural…

Instrumentation and Detectors · Physics 2026-03-26 E. Aprile , J. Aalbers , K. Abe , M. Adrover , S. Ahmed Maouloud , L. Althueser , B. Andrieu , E. Angelino , D. Antón Martin , S. R. Armbruster , F. Arneodo , L. Baudis , M. Bazyk , L. Bellagamba , R. Biondi , A. Bismark , K. Boese , R. M. Braun , G. Bruni , G. Bruno , R. Budnik , C. Cai , C. Capelli , J. M. R. Cardoso , A. P. Cimental Chávez , A. P. Colijn , J. Conrad , J. J. Cuenca-García , V. D'Andrea , L. C. Daniel Garcia , M. P. Decowski , A. Deisting , C. Di Donato , P. Di Gangi , S. Diglio , K. Eitel , S. el Morabit , R. Elleboro , A. Elykov , A. D. Ferella , C. Ferrari , H. Fischer , T. Flehmke , M. Flierman , R. Frankel , D. Fuchs , W. Fulgione , C. Fuselli , R. Gaior , F. Gao , R. Giacomobono , F. Girard , R. Glade-Beucke , L. Grandi , J. Grigat , H. Guan , M. Guida , P. Gyorgy , R. Hammann , A. Higuera , C. Hils , L. Hoetzsch , N. F. Hood , M. Iacovacci , Y. Itow , J. Jakob , F. Joerg , Y. Kaminaga , M. Kara , S. Kazama , P. Kharbanda , M. Kobayashi , D. Koke , K. Kooshkjalali , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , A. Li , I. Li , S. Li , S. Liang , Z. Liang , Y. -T. Lin , S. Lindemann , M. Lindner , K. Liu , M. Liu , F. Lombardi , J. A. M. Lopes , G. M. Lucchetti , T. Luce , Y. Ma , C. Macolino , J. Mahlstedt , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , S. Mastroianni , V. Mazza , A. Melchiorre , J. Merz , M. Messina , A. Michel , K. Miuchi , A. Molinario , S. Moriyama , K. Morå , M. Murra , J. Müller , K. Ni , C. T. Oba Ishikawa , U. Oberlack , S. Ouahada , B. Paetsch , Y. Pan , Q. Pellegrini , R. Peres , J. Pienaar , M. Pierre , G. Plante , T. R. Pollmann , A. Prajapati , L. Principe , J. Qin , D. Ramírez García , A. Ravindran , A. Razeto , R. Singh , L. Sanchez , J. M. F. dos Santos , I. Sarnoff , G. Sartorelli , J. Schreiner , P. Schulte , H. Schulze Eißing , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , F. N. Semler , P. Shagin , S. Shi , H. Simgen , Z. Song , A. Stevens , C. Szyszka , A. Takeda , Y. Takeuchi , P. -L. Tan , D. Thers , G. Trinchero , C. D. Tunnell , K. Valerius , S. Vecchi , S. Vetter , G. Volta , C. Weinheimer , M. Weiss , D. Wenz , C. Wittweg , V. H. S. Wu , Y. Xing , D. Xu , Z. Xu , M. Yamashita , J. Yang , L. Yang , J. Ye , M. Yoshida , L. Yuan , G. Zavattini , Y. Zhao , M. Zhong , T. Zhu

Charge amplification in liquids could provide single-phase xenon time projection chambers with background discrimination and fiducialisation capabilities similar to those found in dual-phase detectors. Although efforts to achieve the high…

Instrumentation and Detectors · Physics 2024-01-05 P. Knights , H. Sekiya , I. Katsioulas , K. Nikolopoulos , K. Kanzawa , I. Giomataris

PET is a functional imaging technique based on detection of annihilation photons following beta decay producing positrons. In this paper, we present the concept of a new PET system for preclinical applications consisting of a ring of twelve…

Instrumentation and Detectors · Physics 2015-03-19 A. Miceli , P. Amaudruz , F. Benard , D. A. Bryman , L. Kurchaninov , J. P. Martin , A. Muennich , F. Retiere , T. J. Ruth , V. Sossi , A. J. Stoessl

The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0\nu\beta\beta$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using…

Nuclear Experiment · Physics 2018-10-23 nEXO Collaboration , J. B. Albert , G. Anton , I. J. Arnquist , I. Badhrees , P. S. Barbeau , D. Beck , V. Belov , F. Bourque , J. P. Brodsky , E. Brown , T. Brunner , A. Burenkov , G. F. Cao , L. Cao , W. R. Cen , C. Chambers , S. A. Charlebois , M. Chiu , B. Cleveland , M. Coon , M. Côté , A. Craycraft , W. Cree , J. Dalmasson , T. Daniels , S. J. Daugherty , J. Daughhetee , R. DeVoe , S. Delaquis , A. Der Mesrobian-Kabakian , T. Didberidze , J. Dilling , Y. Y. Ding , M. J. Dolinski , A. Dragone , L. Fabris , W. Fairbank , J. Farine , S. Feyzbakhsh , R. Fontaine , D. Fudenberg , G. Giacomini , R. Gornea , K. Graham , G. Gratta , E. V. Hansen , D. Harris , M. Hasan , M. Heffner , E. W. Hoppe , J. Hößl , A. House , P. Hufschmidt , M. Hughes , Y. Ito , A. Iverson , A. Jamil , M. J. Jewell , X. S. Jiang , T. N. Johnson , S. Johnston , A. Karelin , L. J. Kaufman , R. Killick , T. Koffas , S. Kravitz , R. Krücken , A. Kuchenkov , K. S. Kumar , Y. Lan , D. S. Leonard , G. Li , S. Li , Z. Li , C. Licciardi , Y. H. Lin , R. MacLellan , T. Michel , B. Mong , D. C. Moore , K. Murray , R. J. Newby , Z. Ning , O. Njoya , F. Nolet , K. Odgers , A. Odian , M. Oriunno , J. L. Orrell , G. S. Ortega , I. Ostrovskiy , C. T. Overman , S. Parent , A. Piepke , A. Pocar , J. -F. Pratte , D. Qiu , V. Radeka , E. Raguzin , T. Rao , S. Rescia , F. Retière , A. Robinson , T. Rossignol , P. C. Rowson , N. Roy , R. Saldanha , S. Sangiorgio , S. Schmidt , J. Schneider , A. Schubert , D. Sinclair , K. Skarpaas VIII , A. K. Soma , G. St-Hilaire , V. Stekhanov , T. Stiegler , X. L. Sun , M. Tarka , J. Todd , T. Tolba , R. Tsang , T. Tsang , F. Vachon , V. Veeraraghavan , G. Visser , P. Vogel , J. -L. Vuilleumier , M. Wagenpfeil , Q. Wang , M. Weber , W. Wei , L. J. Wen , U. Wichoski , G. Wrede , S. X. Wu , W. H. Wu , L. Yang , Y. -R. Yen , O. Zeldovich , J. Zettlemoyer , X. Zhang , J. Zhao , Y. Zhou , T. Ziegler

The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…

Electron diffusion in a liquid xenon time projection chamber has recently been used to infer the $z$ coordinate of a particle interaction, from the width of the electron signal. The goal of this technique is to reduce the background event…

Instrumentation and Methods for Astrophysics · Physics 2015-05-27 Peter Sorensen

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and other rare interactions. It will operate a 50 t liquid xenon detector, with 40 t in the time projection chamber (TPC). To inform the…

Instrumentation and Detectors · Physics 2021-08-25 L. Baudis , Y. Biondi , M. Galloway , F. Girard , A. Manfredini , N. McFadden , R. Peres , P. Sanchez-Lucas , K. Thieme

Possibility to use ultra pure liquid Xenon as a low energy solar neutrino detector by means of $\nu$+e scatterings is evaluated. A possible detector with 10 tons of fiducial volume will give $\sim$14 events for pp-neutrinos and $\sim$6…

High Energy Physics - Phenomenology · Physics 2017-08-23 Y. Suzuki

A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon properties. It does feature a promising insensitive to any…

As noble liquid time projection chambers grow in size their high voltage requirements increase, and detailed, reproducible studies of dielectric breakdown and the onset of electroluminescence are needed to inform their design. The Xenon…

Instrumentation and Detectors · Physics 2020-01-29 L. Tvrznikova , E. P. Bernard , S. Kravitz , K. O'Sullivan , G. Richardson , Q. Riffard , W. L. Waldron , J. Watson , D. N. McKinsey

We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons,…

Liquid xenon offers several features, which make it suitable for applications in nuclear medicine, such as high scintillation yield and fast scintillation decay time. Moreover, being a continuous medium with a uniform response, liquid xenon…

Instrumentation and Detectors · Physics 2021-03-02 Carmen Romo-Luque

NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of Xe-136 using 100 to 150 kg of enriched xenon gas. NEXT-DEMO was built to…

Dual-phase liquid xenon (LXe) detectors lead the direct search for particle dark matter. Understanding the signal production process of nuclear recoils in LXe is essential for the interpretation of LXe based dark matter searches. Up to now,…

Instrumentation and Detectors · Physics 2018-12-12 Elena Aprile , Matthew Anthony , Qing Lin , Zach Greene , Patrick de Perio , Fei Gao , Joseph Howlett , Guillaume Plante , Yun Zhang , Tianyu Zhu

The interaction of radiation with liquid xenon, inducing both scintillation and ionization signals, is of particular interest for Compton-sequences reconstruction. We report on the development and recent results of a liquid-xenon…

A detector using liquid Xenon (LXe) in the scintillation mode is studied for Positron Emission Tomography (PET) of small animals. Its specific design aims at taking full advantage of the Liquid Xenon scintillation properties. This paper…

Large (up to $\sim 100$ kt) liquid argon time-projection chamber detectors are presently being considered for proton decay searches and neutrino astrophysics, as well as for far detectors for the next generation of long-baseline neutrino…

Instrumentation and Detectors · Physics 2015-06-16 Alberto Marchionni

XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory…

The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio…

Instrumentation and Methods for Astrophysics · Physics 2015-05-13 J. Kwong , P. Brusov , T. Shutt , C. E. Dahl , A. I. Bolozdynya , A. Bradley