The Dark Energy Spectroscopic Instrument (DESI) in its first Data Release (DR1) already provides more than 100,000 galaxies with relative distance measurements. The primary purpose of this paper is to perform the calibration of the…

A basic prototype for an analog hadron calorimeter for a future linear collider detector is currently being realized by the CALICE collaboration. The aim is to show the feasibility to build a realistic detector with fully integrated readout…

Instrumentation and Detectors · Physics 2019-08-14 Mark Terwort

We conduct a thorough study of photometric stereo under nearby point light source illumination, from modeling to numerical solution, through calibration. In the classical formulation of photometric stereo, the luminous fluxes are assumed to…

Computer Vision and Pattern Recognition · Computer Science 2017-09-05 Yvain Quéau , Bastien Durix , Tao Wu , Daniel Cremers , François Lauze , Jean-Denis Durou

During the process of robot-assisted ultrasound(US) puncture, it is important to estimate the location of the puncture from the 2D US images. To this end, the calibration of the US image becomes an important issue. In this paper, we…

Robotics · Computer Science 2023-08-11 Fuqiang Zhao , Mingchang Li , Mengde Li , Zhongtao Fu , Miao Li

Illumination estimation is the essential step of computational color constancy, one of the core parts of various image processing pipelines of modern digital cameras. Having an accurate and reliable illumination estimation is important for…

Lighting design and modelling or industrial applications like luminaire planning and commissioning rely heavily on time consuming manual measurements or on physically coherent computational simulations. Regarding the latter,standard…

Computer Vision and Pattern Recognition · Computer Science 2018-12-10 Theodore Tsesmelis , Irtiza Hasan , Marco Cristani , Fabio Galasso , Alessio Del Bue

Accurately calibrating light field camera is essential to its applications. Rapid progress has been made in this area in the past decades. In this paper, detailed analysis was first performed towards the state of the art projection models…

Computer Vision and Pattern Recognition · Computer Science 2021-03-11 Dongyang Jin , Saiping Zhang , Xiao Huo , Wei Zhang , Fuzheng Yang

The electro-magnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with good resolution. The calorimeter is calibrated at the low energy end with 6.13…

Instrumentation and Detectors · Physics 2019-08-14 Johannes M. Bauer

A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant…

Instrumentation and Detectors · Physics 2010-02-09 M. Weierganz , D. Bar , B. Bromberger , V. Dangendorf , G. Feldman , M. B. Goldberg , M. Lindemann , I. Mor , K. Tittelmeier , D. Vartsky

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high…

Instrumentation and Detectors · Physics 2009-09-29 CALICE Collaboration , J. Repond , J. Yu , C. M. Hawkes , Y. Mikami , O. Miller , N. K. Watson , J. A. Wilson , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , F. Badaud , D. Boumediene , C. Carloganu , R. Cornat , P. Gay , Ph. Gris , S. Manen , F. Morisseau , L. Royer , G. C. Blazey , D. Chakraborty , A. Dyshkant , K. Francis , D. Hedin , G. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , E. Garutti , V. Korbel , F. Sefkow , M. Groll , G. Kim , D-W. Kim , K. Lee , S. Lee , K. Kawagoe , Y. Tamura , D. A. Bowerman , P. D. Dauncey , A. -M. Magnan , C. Noronha , H. Yilmaz , O. Zorba , V. Bartsch , J. M. Butterworth , M. Postranecky , M. Warren , M. Wing , M. Faucci Giannelli , M. G. Green , F. Salvatore , T. Wu , D. Bailey , R. J. Barlow , M. Kelly , S. Snow , R. J. Thompson , M. Danilov , V. Kochetkov , N. Baranova , P. Ermolov , D. Karmanov , M. Korolev , M. Merkin , A. Voronin , B. Bouquet , S. Callier , F. Dulucq , J. Fleury , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , M. Ruan , N. Seguin-Moreau , F. Wicek , Z. Zhang , M. Anduze , V. Boudry , J-C. Brient , C. Clerc , G. Gaycken , C. Jauffret , A. Karar , P. Mora de Freitas , G. Musat , M. Reinhard , A. Rouge , A. L. Sanchez , J-Ch. Vanel , H. Videau , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , Yu. Arestov , A. Baird , R. N. Halsall , S. W. Nam , I. H. Park , J. Yang

A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a…

Instrumentation and Detectors · Physics 2014-07-24 CALICE Collaboration , K. Francis , J. Repond , J. Schlereth , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , G. Eigen , Y. Mikami , N. K. Watson , M. A. Thomson , D. R. Ward , D. Benchekroun , A. Hoummada , Y. Khoulaki , J. Apostolakis , A. Dotti , G. Folger , V. Ivantchenko , A. Ribon , V. Uzhinskiy , C. Carloganu , P. Gay , S. Manen , L. Royer , M. Tytgat , N. Zaganidis , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , A. Ebrahimi , G. Falley , K. Gadow , P. Goettlicher , C. Guenter , O. Hartbrich , B. Hermberg , S. Karstensen , F. Krivan , K. Krueger , B. Lutz , S. Morozov , V. Morgunov , C. Neubueser , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , E. Garutti , S. Laurien , S. Lu , I. Marchesini , M. Matysek , M. Ramilli , K. Briggl , P. Eckert , T. Harion , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , B. Bilki , E. Norbeck , D. Northacker , Y. Onel , G. W. Wilson , K. Kawagoe , Y. Sudo , T. Yoshioka , P. D. Dauncey , M. Wing , F. Salvatore , E. Cortina Gil , S. Mannai , G. Baulieu , P. Calabria , L. Caponetto , C. Combaret , R. Della Negra , G. Grenier , R. Han , J-C. Ianigro , R. Kieffer , I. Laktineh , N. Lumb , H. Mathez , L. Mirabito , A. Petrukhin , A. Steen , W. Tromeur , M. Vander Donckt , Y. Zoccarato , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , F. Corriveau , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Popov , V. Rusinov , E. Tarkovsky , D. Besson , P. Buzhan , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , V. Tikhomirov , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , M. S. Amjad , J. Bonis , S. Callier , S. Conforti di Lorenzo , P. Cornebise , Ph. Doublet , F. Dulucq , J. Fleury , T. Frisson , N. van der Kolk , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Poeschl , L. Raux , J. Rouene , N. Seguin-Moreau , M. Anduze , V. Balagura , V. Boudry , J-C. Brient , R. Cornat , M. Frotin , F. Gastaldi , E. Guliyev , Y. Haddad , F. Magniette , G. Musat , M. Ruan , T. H. Tran , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , H. Ono , T. Takeshita , S. Uozumi , D. Jeans , S. Chang , A. Khan , D. H. Kim , D. J. Kong , Y. D. Oh , M. Goetze , J. Sauer , S. Weber , C. Zeitnitz

The ICARUS T600 LAr TPC is the far detector of the Short Baseline Program at FNAL. As it will have to work at shallow depth in the Booster Neutrino Beam, a large cosmic rays background ($\sim 11$ kHz) will be present. To reduce it, precise…

Instrumentation and Detectors · Physics 2020-06-24 M. Bonesini , R. Benocci , R. Bertoni , A. Falcone , R. Mazza , M. Torti , A. Menegolli , G. L. Raselli , M. Rossella

With the rise of neutrino astronomy using large-volume detector arrays, calibration improvements of optical media and photosensors have emerged as significant means to reduce detector systematics. To improve understanding of the detector…

Instrumentation and Methods for Astrophysics · Physics 2020-08-26 F. Henningsen , M. Boehmer , A. Gärtner , L. Geilen , R. Gernhäuser , H. Heggen , K. Holzapfel , C. Fruck , L. Papp , I. C. Rea , E. Resconi , F. Schmuckermaier , C. Spannfellner , M. Traxler

CLIC is a proposed linear e+e- collider designed to provide particle collisions at center-of-mass energies of up to 3 TeV. Precise measurements of the properties of the top quark and the Higgs boson, as well as searches for Beyond the…

Instrumentation and Detectors · Physics 2017-06-21 Simon Spannagel

Modern observatories and instruments require optics fabricated at larger sizes with more stringent performance requirements. The Daniel K. Inouye Solar Telescope will be the world's largest solar telescope at 4.0 m aperture delivering a 300…

Instrumentation and Methods for Astrophysics · Physics 2018-11-27 D. M. Harrington , S. R. Sueoka

Transforming the instrumental photometry of ground-based telescopes into a calibrated physical flux in a well-defined passband is a major challenge in astronomy. Along with the intrinsic instrumental difference between telescopes sharing…

Instrumentation and Methods for Astrophysics · Physics 2025-07-08 S. Garrappa , E. O. Ofek , S. Ben-Ami , D. Polishook , A. Gal-Yam , Y. Shvartzvald , A. Krassilchtchikov , R. Konno , E. Segre , Y. M. Shani , Y. Sofer-Rimalt , M. Engel , A. Blumenzweig

This paper is devoted to studying the CIB through its correlation properties. We studied the limits on CIB anisotropy in the near IR (1.25, 2.2, and 3.5 \um, or $J,\;K,\;L$) bands at a scale of 0.7\deg\ using the COBE\footnote{ The National…

Astrophysics · Physics 2009-10-28 A. Kashlinsky , J. C. Mather , S. Odenwald , M. Hauser

We present the characterization of the CCD system developed for the ADFOSC instrument on the 3.6m Devasthal Optical Telescope (DOT). We describe various experiments performed to tune the CCD controller parameters to obtain optimum…

Instrumentation and Methods for Astrophysics · Physics 2023-01-24 Dimple , T. S. Kumar , A. Omar , K. Misra

The Compact Linear Collider CLIC is designed to deliver e+e- collisions at a center of mass energy of up to 3 TeV. The detector systems at this collider have to provide highly efficient tracking and excellent jet energy resolution and…

Instrumentation and Detectors · Physics 2011-09-16 Frank Simon

``Oversimplified'' and ``simplified'' methods based on true coincidence summing effect used in uncomplicated determination of the photo-peak efficiency of the semiconductor High Purity Germanium (HPGe) detector system are suggested and…