English

The laser diode calibration system of the ICARUS T600 detector at FNAL

Instrumentation and Detectors 2020-06-24 v1

Abstract

The ICARUS T600 LAr TPC is the far detector of the Short Baseline Program at FNAL. As it will have to work at shallow depth in the Booster Neutrino Beam, a large cosmic rays background (11\sim 11 kHz) will be present. To reduce it, precise timing information is needed from the new light detection system, based on 360 large area photomultipliers. For precise time measurements a calibration system based on a fast laser diode and a system based on one optical switch, several 1×101 \times 10 fused fiber splitters, ultra-high vacuum optical feedthroughs and multimode optical patchcords up to 20 m long, to distribute the laser pulses to each single PMT, was designed. The time evolution of the PMTs' gain/timing and possibly their initial calibrations at a time t0t_0 will be done by using this system. The expected time resolution of this calibration system will be around 100 ps. The laboratory tests needed to set up the system are reported.

Keywords

Cite

@article{arxiv.2003.12883,
  title  = {The laser diode calibration system of the ICARUS T600 detector at FNAL},
  author = {M. Bonesini and R. Benocci and R. Bertoni and A. Falcone and R. Mazza and M. Torti and A. Menegolli and G. L. Raselli and M. Rossella},
  journal= {arXiv preprint arXiv:2003.12883},
  year   = {2020}
}

Comments

Proceedings, 15th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD19) : Siena, Italy, October 14-17, 2019