Related papers: A new method of energy calibration of position-sen…
We report on a recently developed novel type of large area (62 mm x 62 mm) position sensitive silicon detector with four-corner readout. It consists of a square-shaped ion-implanted resistive anode framed by additional low-resistivity…
The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with…
A method for the calibration of a Silicon Position Sensitive Detector is described. From the combination of the signals collected at the ends of the resistive electrode, energy and angle of the hitting particle are reconstructed with a…
This paper presents the electron and photon energy calibration obtained with the ATLAS detector using 140 fb$^{-1}$ of LHC proton-proton collision data recorded at $\sqrt{s}=13$ TeV between 2015 and 2018. Methods for the measurement of…
In order to cope with increasing lifetime radiation damage expected at collider experiments, silicon sensors are becoming increasingly thin. To achieve adequate detection efficiency, the next generation of detectors may have to operate with…
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$\mu$m and a resolution of…
Although reliable models may predict the detection efficiency of semiconductor detectors, measurements are needed to check the parameters supplied by the manufacturers namely the thicknesses of dead layer, beryllium window and crystal…
This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb$^{-1}$ of LHC proton--proton collision data taken at centre-of-mass energies of $\sqrt{s}$ = 7 and 8 TeV. The reconstruction…
The energy calibration of calorimeters at collider experiments, such as the ones at the CERN Large Hadron Collider, is crucial for achieving the experiments physics objectives. Standard calibration approaches have limitations that become…
In a neutrinoless double-beta decay ($0\nu\beta\beta$) experiment, energy resolution is important to distinguish between $0\nu\beta\beta$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy…
A photon-counting silicon strip detector with two energy thresholds was investigated for spectral X-ray imaging in a mammography system. Preliminary studies already indicate clinical benefit of the detector, and the purpose of the present…
This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with…
This report is to provide a novel method for the lepton energy calibration at Hadron Collider Experiments. The method improves the classic lepton energy calibration procedure widely used at hadron collider experiments. The classic method…
The discovery potential for charged Higgs bosons has been studied including background simulations for sqrts = 500 GeV and a luminosity of 10 fb-1 depending on the hadronic calorimeter resolution of a LC500 detector. The hadronic decay…
This paper presents the electron and photon energy calibration obtained with the ATLAS detector using about 36 fb$^{-1}$ of LHC proton-proton collision data recorded at $\sqrt{s}=13$ TeV in 2015 and 2016. The different calibration steps…
One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and…
A graphene-optimized silicon carbide PIN detector was fabricated and its radiation tolerance under X-ray irradiation of 160 keV was evaluated. Its electrical properties, charge collection performance and time resolution of beta-particles…
The energy loss of charged particles in silicon can be approximated by a simple analytical model. With help of measured charge deposits in individual channels of hit clusters their position and energy can be estimated. Deposits below…
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled…
It is challenging to achieve high precision energy resolution for large liquid scintillator detectors. Energy non-uniformity is one of the main obstacles. To surmount it, a calibration-data driven method was developed previously to…