English
Related papers

Related papers: Analysis of digital timing methods with DRS4 modul…

200 papers

We have developed a Time-to-Digital Converter (TDC) application in a Xilinx Kintex-7 Field Programmable Gate Array (FPGA). This TDC, based on the Tapped-Delay Line (TDL) and Wave Union A (WU-A) techniques, achieves an independent time…

Instrumentation and Detectors · Physics 2024-12-30 Zehong Liang , Xiongbo Yan , Zhe Ning , Jun Hu , Xiaoshan Jiang , Yunhua Sun , Weiyan Pan , Jingbo Ye

This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This…

Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…

Instrumentation and Detectors · Physics 2025-02-12 Shiv K. Subedi , Simon R. Cherry , Yi Qiang , Peng Peng

For TOF positron emission tomography (TOF PET) detectors, time-to-digital converters (TDCs) are essential to resolve the coincidence time of the photon pairs. Recently, an efficient TDC structure called ring-oscillator-based (RO-based)…

Instrumentation and Detectors · Physics 2017-06-12 Ke Cui , Xiangyu Li , Zongkai Liu , Rihong Zhu

The time precision achievable using standard analog methods is well known. Several expressions for timing methods using digitized signals have been recently proposed in workshops, conferences or training courses. Most of them are only…

Instrumentation and Detectors · Physics 2016-06-20 Eric Delagnes

Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a…

Pulse-shape analysis of the ionization signals from germanium gamma-ray spectrometers is a method for obtaining information that can characterize an event beyond just the total energy deposited in the crystal. However, as typically…

Nuclear Experiment · Physics 2008-11-26 R. Suarez , J. L. Orrell , C. E. Aalseth , T. W. Hossbach , H. S. Miley

The LaBr3:Ce scintillator has been widely studied for nuclear spectroscopy because of its optimal energy resolution (<3%@ 662 keV) and time resolution (~300 ps). Despite these promising properties, the intrinsic radiation background of…

Instrumentation and Detectors · Physics 2021-09-03 Ming Zeng , Jirong Cang , Zhi Zeng , Xiaoguang Yue , Jianping Cheng , Yinong Liu , Junli Li

We are exploring a scintillator-based detector with potential of high sensitivity, DOI capability and timing resolution in a single-side readout configuration. Our concept combines: 1) A design with 2+ crystal arrays stacked with relative…

Instrumentation and Detectors · Physics 2021-04-08 L. Bläckberg , S. Sajedi , G. El Fakhri , H. Sabet

We demonstrate a hybrid distributed fiber sensing system for multi-parameter detection. The integration of phase-sensitive optical time domain reflectometry ({\Phi}-OTDR) and Brillouin optical time domain reflectometry (B-OTDR) enables…

Optics · Physics 2016-09-02 Jingdong Zhang , Tao Zhu , Huan Zhou , Yang Li , Min Liu , Wei Huang

We report on the measurements performed using a 22Na source on a detector element for an MRI-compatible TOF-PET endorectal prostate probe, with Depth-Of-Interaction sensitivity. It is made from a LYSO scintillator crystal, wrapped with…

Instrumentation and Detectors · Physics 2015-06-11 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each…

A novel quadrature Doppler Backscattering (DBS) system has been developed and optimized for the E-band (60-90GHz) frequency range using either O-mode or X-mode polarization in DIII-D plasmas. In general, DBS measures the amplitude of…

An FPGA based digital signal processing (DSP) system for biasing and reading out multiplexed bolometric detectors for mm-wavelength telescopes is presented. This readout system is being deployed for balloon-borne and ground based cosmology…

Instrumentation and Detectors · Physics 2009-05-13 Matt Dobbs , Eric Bissonnette , Helmuth Spieler

With present-day detectors in high energy physics one often faces fast analog pulses of a few nanoseconds length which cover large dynamic ranges. In many experiments both amplitude and timing information have to be measured with high…

We have developed a new laser-based time calibration system for highly segmented scintillator counters like the MEG II pixelated Timing Counter (pTC), consisting of 512-centimeter scale scintillator counters read out by silicon…

Fast timing detectors are an essential element in the experimental setup for time-of-flight (ToF) mass measurements of unstable nuclei. We have upgraded the scintillator detectors used in experiments at the National Superconducting…

We present a new parallel algorithm for probabilistic graphical model optimization. The algorithm relies on data-parallel primitives (DPPs), which provide portable performance over hardware architecture. We evaluate results on CPUs and GPUs…

Distributed, Parallel, and Cluster Computing · Computer Science 2018-09-14 Brenton Lessley , Talita Perciano , Colleen Heinemann , David Camp , Hank Childs , E. Wes Bethel

A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of…

Instrumentation and Detectors · Physics 2016-06-01 M. Bonesini , R. Bertoni , A. deBari , M. Rossella

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to…