English
Related papers

Related papers: Analysis of digital timing methods with DRS4 modul…

200 papers

The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a…

In this study, we evaluate and compare the pulse shape discrimination (PSD) performance of multipixel photon counters (MPPCs, also known as silicon photomultiphers - SiPMs) with that of a typical photomultiplier tube (PMT) when testing…

Instrumentation and Detectors · Physics 2021-01-06 Nguyen V. H. Viet , M. Nomachi , K. Takahisa , T. Shima , B. T. Khai , R. Takaishi , K. Miyamoto

In many physical experiments and applications with photomultiplier tubes (PMTs), high-speed pulse digitalization is used extensively. The current pulse from a PMT has a rising time of several to a hundred nanoseconds. The current pulse…

Instrumentation and Detectors · Physics 2019-10-08 Tao Xue , Jinfu Zhu , Guanghua Gong , Liangjun Wei , Jianmin Li

Time-tagging units and coincidence detectors are used in many scientific research fields. The required timing resolution and number of input channels are varying, but some emerging experiments in the field of quantum optics require up to 32…

Instrumentation and Detectors · Physics 2020-11-03 Attila Hidvegi

In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…

Instrumentation and Detectors · Physics 2018-05-09 K. Mahata , A. Shrivastava , J. A. Gore , S. K. Pandit , V. V. Parkar , K. Ramachandran , A. Kumar , S. Gupta , P. Patale

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and…

Instrumentation and Detectors · Physics 2023-04-05 Jianxin Zhou , Abdullah Abdulaziz , Yoann Altmann , Angela Di Fulvio

We present a principal component analysis method which tracks and compensates for short-timescale variability in pulsar profiles, with a goal of improving pulsar timing precision. We couple this with a fast likelihood technique for…

Instrumentation and Methods for Astrophysics · Physics 2017-12-13 Hsiu-Hsien Lin , Kiyoshi Masui , Ue-Li Pen , Jeffrey B. Peterson

Plastic scintillation detectors represent an efficient, cost-effective, customizable solution for assessment of gamma radiation fields in the context of nuclear security, environmental radiation survey, radiological and nuclear incidents…

Instrumentation and Detectors · Physics 2021-12-08 Paolo Tancioni , Ulisse Gendotti

In recent years, instrumentation enabling pulsar observations with unprecedentedly high fractional bandwidth has been under development which can be used to substantially improve the precision of pulsar timing experiments. The traditional…

Timing systems based on Analog-to-Digital Converters are widely used in the design of previous high energy physics detectors. In this paper, we propose a new method based on deep learning to extract the time information from a finite set of…

Data Analysis, Statistics and Probability · Physics 2019-04-02 Pengcheng Ai , Dong Wang , Guangming Huang , Ni Fang , Deli Xu , Fan Zhang

Fast-speed and high-accuracy three-dimensional (3D) shape measurement has been the goal all along in fringe projection profilometry (FPP). The dual-frequency temporal phase unwrapping method (DF-TPU) is one of the prominent technologies to…

Image and Video Processing · Electrical Eng. & Systems 2023-05-31 Xiaomin Gao , Wanzhong Song , Chunqian Tan , Junzhe Lei

DANTE is a new Digital Pulse Processor (DPP) developed for fluorescence detectors, like silicon drift detectors (SDDs) or High Purity Germanium detectors (HPGe), used in X-ray Fluorescence (XRF) and X-ray Absorption Spectroscopy (XAS)…

Instrumentation and Detectors · Physics 2023-06-28 F. J. Iguaz , L. Bombelli , S. Meo , F. Orsini , S. Schöeder , A. Tocchio , N. Trcera , D. Vantelon

We propose discrete-time polarization mode dispersion (PMD) models that are compatible with the emerging coherent receiver techniques, and statistical sampling schemes for the model parameters. These models use multiple-input…

Optics · Physics 2012-12-06 A. Gokcen Mahmutoglu , Alper T. Erdogan , Alper Demir

Digital fringe projection (DFP) enables micrometer-level 3D reconstruction, yet extending it to large-scale mapping remains challenging because six-degree-of-freedom pose estimation often cannot match the reconstruction's precision.…

Computer Vision and Pattern Recognition · Computer Science 2026-03-13 Sehoon Tak , Keunhee Cho , Sangpil Kim , Jae-Sang Hyun

Central exclusive processes can be studied in CMS by combining the information of the central detector with the Precision Proton Spectrometer (PPS). PPS detectors, placed symmetrically at more than 200 m from the interaction point, can…

Instrumentation and Detectors · Physics 2020-06-24 Edoardo Bossini

This review presents a comprehensive survey and benchmark of pulse shape discrimination (PSD) algorithms for radiation detection, classifying nearly sixty methods into statistical (time-domain, frequency-domain, neural network-based) and…

Machine Learning · Computer Science 2026-04-21 Haoran Liu , Yihan Zhan , Mingzhe Liu , Yanhua Liu , Peng Li , Zhuo Zuo , Bingqi Liu , Runxi Liu

We present the development and characterization of a generic, reconfigurable, low-cost ($<$ 350 USD) software-defined digital receiver system (DRS) for temporal correlation measurements in atomic spin ensembles. We demonstrate the use of…

Instrumentation and Detectors · Physics 2021-01-26 V. Mugundhan , Maheswar Swar , Subhajit Bhar , Saptarishi Chaudhuri

Measurements from particle timing detectors are often affected by the time walk effect caused by statistical fluctuations in the charge deposited by passing particles. The constant fraction discriminator (CFD) algorithm is frequently used…

Instrumentation and Detectors · Physics 2024-03-19 Mateusz Kocot , Krzysztof Misan , Valentina Avati , Edoardo Bossini , Leszek Grzanka , Nicola Minafra

We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters…

Instrumentation and Detectors · Physics 2016-06-22 J. -B. Mosset , A. Stoykov , U. Greuter , M. Hildebrandt , N. Schlumpf

Monte Carlo simulation plays an important role in the study of time of flight (TOF) positron emission tomography (PET) prototype. As it can incorporate accurate physical modeling of scintillation detection process, from scintillation light…

Instrumentation and Detectors · Physics 2013-09-17 Ze Chen , Zheng-Guo Hu , Jin-Da Chen , Xiu-Ling Zhang , Zhi-Yu Sun , Wen-Xue Huang , Jian-Song Wang , Zhong-Yan Guo , Guo-Qing Xiao